The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Micro- and Macro-Attenuated Total Reflection Fourier Transform Infrared Spectroscopic Imaging: Plenary Lecture at the 5th International Conference on Advanced Vibrational Spectroscopy, 2009, Melbourne, Australia
Abstract
Fourier transform infrared (FT-IR) spectroscopic imaging has become a very powerful method in chemical analysis. In this review paper we describe a variety of opportunities for obtaining FT-IR images using the attenuated total reflection (ATR) approach and provide an overview of fundamental aspects, accessories, and applications in both micro- and macro-ATR imaging modes. The advantages and versatility of both ATR imaging modes are discussed and the spatial resolution of micro-ATR imaging is demonstrated. Micro-ATR imaging has opened up many new areas of study that were previously precluded by inadequate spatial resolution (polymer blends, pharmaceutical tablets, cross-sections of blood vessels or hair, surface of skin, single live cells, cancerous tissues). Recent applications of ATR imaging in polymer research, biomedical and forensic sciences, objects of cultural heritage, and other complex materials are outlined. The latest advances include obtaining spatially resolved chemical images from different depths within a sample, and surface-enhanced images for macro-ATR imaging have also been presented. Macro-ATR imaging is a valuable approach for high-throughput analysis of materials under controlled environments. Opportunities exist for chemical imaging of dynamic aqueous systems, such as dissolution, diffusion, microfluidics, or imaging of dynamic processes in live cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effective Path Length in Attenuated Total Reflection Spectroscopy
Averett, L. A., Griffiths, P. R., & Nishikida, K. (2008) · Analytical Chemistry · doi:10.1021/ac7025892 · Cited by 133
Cited by
ATR-FTIR spectroscopic imaging: recent advances and applications to biological systems
Kazarian, S. G., & Chan, K. L. A. (2013) · The Analyst · doi:10.1039/c3an36865c · Cited by 414
Self-citationAdato, R., & Altug, H. (2013) · Nature Communications · doi:10.1038/ncomms3154 · Cited by 406
Metadata
- Authors
- Kazarian, S. G., & Chan, K. L. A.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2010-05
- Volume
- 64
- Issue
- 5
- Pages
- 135A-152A
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2115917144
- Cited by
- 207
- References
- 1
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Micro- and Macro-Attenuated Total Reflection Fourier Transform Infrared Spectroscopic Imaging: Plenary Lecture at the 5th International Conference on Advanced Vibrational Spectroscopy, 2009, Melbourne, Australia. https://app.cochat.ai/papers/10.1366/000370210791211673
- The paper
- Kazarian, S. G., & Chan, K. L. A. (2010). Micro- and Macro-Attenuated Total Reflection Fourier Transform Infrared Spectroscopic Imaging: Plenary Lecture at the 5th International Conference on Advanced Vibrational Spectroscopy, 2009, Melbourne, Australia. Applied Spectroscopy. https://doi.org/10.1366/000370210791211673
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.