Vibrational Intensities XXV: Some Systematic Errors in Infrared Absorption Spectrophotometry of Liquid Samples
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
It is shown that the characteristic working parameters of infrared absorption spectrophotometry of liquids give rise to inevitable reflection and interference effects which grossly distort band shapes and integrated intensities and which seem to account for the long-observed and frustrating variability in apparent peak absorption coefficients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Intensities and Shapes of Infrared Absorption Bands of Substances in the Liquid Phase
Ramsay, D. A. (1952) · Journal of the American Chemical Society · doi:10.1021/ja01121a018 · Cited by 673
Chemical infrared spectroscopy
Potts, W. J. (1963) · Wiley eBooks · Cited by 105
Absolute Infrared Intensities in Crystalline Benzene
Hollenberg, J. L., & Dows, D. A. (1962) · The Journal of Chemical Physics · doi:10.1063/1.1733278 · Cited by 97
Vibrational Intensities. XIII. Reduction of Attenuated Total Reflection Data to Optical Constants
Gilby, A. C., Burr, J. C., Krueger, W. J., & Crawford, B. L. (1966) · The Journal of Physical Chemistry · doi:10.1021/j100877a031 · Cited by 58
Self-citationVibrational intensities. XXI. Some band shapes and intensities in liquid hexafluorobenzene
Fujiyama, T., & Crawford, B. L. (1968) · The Journal of Physical Chemistry · doi:10.1021/j100852a050 · Cited by 48
Self-citationAbsolute Infrared Intensity Measurements in Thin Films
Maeda, S., & Schatz, P. N. (1961) · The Journal of Chemical Physics · doi:10.1063/1.1732118 · Cited by 46
Research works printed but not linked: 4
- Jones Norman R., 1967, Japan. J. Chem., 21, 609
- 1966, “Manual on Recommended Practices in Spectrophotometry,”
- Potts W. J., Chemical Infrared Spectroscopy (John Wiley & Sons, Inc., New York, 1963), pp. 117 ff
- Born M., 1964, Principles of Optics
Cited by
The Bouguer-Beer-Lambert Law: Shining Light on the Obscure
Mayerhöfer, T. G., Pahlow, S., & Popp, J. (2020) · ChemPhysChem · doi:10.1002/cphc.202000464 · Cited by 671
Hawranek, J. P., Neelakantan, P., Young, R. P., & Jones, R. N. (1976) · Spectrochimica Acta Part A Molecular Spectroscopy · doi:10.1016/0584-8539(76)80055-4 · Cited by 127
Fourier Transform Infrared Spectroscopy Investigations of Protein Structure
Cooper, E. A., & Knutson, K. (1995) · Pharmaceutical biotechnology · doi:10.1007/978-1-4899-1079-0_3 · Cited by 125
The control of errors in i.r. spectrophotometry—III. Transmission measurements using thin cells
Hawranek, J. P., Neelakantan, P., Young, R. P., & Jones, R. N. (1976) · Spectrochimica Acta Part A Molecular Spectroscopy · doi:10.1016/0584-8539(76)80054-2 · Cited by 116
Optical Constant Determination of Thin Polymer Films in the Infrared
Graf, R. T., Koenig, J. L., & Ishida, H. (1985) · Applied Spectroscopy · doi:10.1366/0003702854248539 · Cited by 94
Metadata
- Authors
- Fujiyama, T., Herrin, J., & Crawford, B. L.
- Affiliations
- University of Minnesota (US)
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 1970-01
- Volume
- 24
- Issue
- 1
- Pages
- 9-15
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2050994577
- Cited by
- 39
- References
- 6
- Citations by year
- 2024: 1 · 2020: 2 · 2017: 2 · 2015: 1
- FWCI
- 2.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Applied Spectroscopy (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Spectroscopy and Quantum Chemical Studies
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Keywords
- liquid samples, systematic errors, reflection effect, interference effects, integrated intensity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.