Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 246

The DOI matches its Crossref record.

Time-Resolved FT-IR Absorption Spectroscopy Using a Step-Scan Interferometer

Uhmann, Wolfgang, Becker, Andreas, Taran, Christoph, Siebert, Friedrich · 1991 · Applied Spectroscopy

Abstract

The implementation of time-resolved step-scan FT-IR spectroscopy with a commercial interferometer is described. With the use of the photo-reaction of the biological system bacteriorhodopsin as an example which exhibits infrared spectral changes smaller than 10−2 absorbance units, the quality of the method is demonstrated. A comparison with conventional flash-photolysis experiments with a monochromatic infrared monitoring beam clearly demonstrates the multiplex advantage. The advantage of covering the total time course of the reaction allows for a variety of data analysis, such as forming difference spectra between intermediates of the reaction and the deduction of time courses of absorbance changes at selected wavenumbers. The mirror stability is better than ±1.5 nm, which is sufficient for the reliable measurement of small absorbance changes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1366/0003702914337128

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 246

Metadata

Authors
Uhmann, W., Becker, A., Taran, C., & Siebert, F.
Venue
Applied Spectroscopy
Published
1991-03
Volume
45
Issue
3
Pages
390-397
ISSN
  • 0003-7028 (ISSN-L)
  • 1943-3530
OpenAlex
W1997927029
Cited by
246
References
0
FWCI
10.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Time-Resolved FT-IR Absorption Spectroscopy Using a Step-Scan Interferometer. https://app.cochat.ai/papers/10.1366/0003702914337128
The paper
Uhmann, W., Becker, A., Taran, C., & Siebert, F. (1991). Time-Resolved FT-IR Absorption Spectroscopy Using a Step-Scan Interferometer. Applied Spectroscopy. https://doi.org/10.1366/0003702914337128

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.