The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Matrix Effects in the Detection of Pb and Ba in Soils Using Laser-Induced Breakdown Spectroscopy
Abstract
With the use of laser-induced breakdown spectroscopy (LIBS), the effects of chemical speciation and matrix composition on Pb and Ba measurements have been investigated by using sand and soil matrices. A cylindrical lens was used to focus the laser pulses on the samples because it yielded higher measurement precision than a spherical lens for the experimental conditions used here. The detection limits for Pb and Ba spiked in a sand matrix were 17 and 76 ppm (w/w), respectively. In spiked soil, the detection limits were 57 and 42 ppm (w/w) for Pb and Ba, respectively. Measurement precision for five replicate measurements was typically 10% RSD or less. Two factors were found to influence emissions from Pb and Ba present in sand and soil matrices as crystalline compounds: (1) compound speciation, where Ba emission intensities varied in the order carbonate > oxide > sulfate > chloride > nitrate, and where Pb emission intensities varied in the order oxide > carbonate > chloride > sulfate > nitrate; and (2) the composition of the bulk sample matrix. Emissions from Ba(II) correlated inversely with the plasma electron density, which in turn was dependent upon the percent sand in a sand/soil mixture. The analytical results obtained here show that a field-screening instrument based on LIBS would be useful for the initial screening of soils contaminated with Pb and Ba.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Error Analysis
Taylor, J. R. (1982) · Medical Entomology and Zoology · Cited by 2,807
Laser induced plasmas and applications
Hall, T. A. (1991) · Optics and Lasers in Engineering · doi:10.1016/0143-8166(91)90007-g · Cited by 587
Detector for Trace Elemental Analysis of Solid Environmental Samples by Laser Plasma Spectroscopy
Wisbrun, R., Schechter, I., Niessner, R., Schroeder, H., & Kompa, K. L. (1994) · Analytical Chemistry · doi:10.1021/ac00090a026 · Cited by 244
The Analysis of Metals at a Distance Using Laser-Induced Breakdown Spectroscopy
Cremers, D. A. (1987) · Applied Spectroscopy · doi:10.1366/0003702874448742 · Cited by 184
Self-citationDarke, S. A., & Tyson, J. F. (1993) · Journal of Analytical Atomic Spectrometry · doi:10.1039/ja9930800145 · Cited by 121
Cited by
Hahn, D. W., & Omenetto, N. (2012) · Applied Spectroscopy · doi:10.1366/11-06574 · Cited by 1,497
New Procedure for Quantitative Elemental Analysis by Laser-Induced Plasma Spectroscopy
Ciucci, A., Corsi, M., Palleschi, V., Rastelli, S., Salvetti, A., & Tognoni, E. (1999) · Applied Spectroscopy · doi:10.1366/0003702991947612 · Cited by 879
Winefordner, J. D., Gornushkin, I. B., Correll, T., Gibb, E., Smith, B. W., & Omenetto, N. (2004) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b400355c · Cited by 486
Tognoni, E., Palleschi, V, Corsi, M., & Cristoforetti, G. (2002) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/s0584-8547(02)00053-8 · Cited by 456
Characterization of Laser-Induced Breakdown Spectroscopy (LIBS) for Application to Space Exploration
Knight, A. K., Scherbarth, N. L., Cremers, D. A., & Ferris, M. J. (2000) · Applied Spectroscopy · doi:10.1366/0003702001949591 · Cited by 432
Self-citation
Metadata
- Authors
- Eppler, A. S., Cremers, D. A., Hickmott, D. D., Ferris, M. J., & Koskelo, A. C.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 1996-09
- Volume
- 50
- Issue
- 9
- Pages
- 1175-1181
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W1995683489
- Cited by
- 298
- References
- 5
- FWCI
- 15.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Matrix Effects in the Detection of Pb and Ba in Soils Using Laser-Induced Breakdown Spectroscopy. https://app.cochat.ai/papers/10.1366/0003702963905123
- The paper
- Eppler, A. S., Cremers, D. A., Hickmott, D. D., Ferris, M. J., & Koskelo, A. C. (1996). Matrix Effects in the Detection of Pb and Ba in Soils Using Laser-Induced Breakdown Spectroscopy. Applied Spectroscopy. https://doi.org/10.1366/0003702963905123
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.