The DOI matches its Crossref record.
Review of Super-Resolution Fluorescence Microscopy for Biology
Abstract
Several methodologies have been developed over the past several years for super-resolution fluorescence microscopy including saturated structured-illumination microscopy (SSIM), stimulated emission depletion microscopy (STED), photoactivated localization microscopy (PALM), fluorescence photoactivation localization microscopy (FPALM), and stochastic optical reconstruction microscopy (STORM). While they have shown great promise for biological research, these techniques all have individual strengths and weaknesses. This review will describe the basic principles for achieving super resolution, demonstrate some applications in biology, and provide an overview of technical considerations for implementing these methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Li, X., Corbett, A. L., Taatizadeh, E., Tasnim, N., Little, J. P., Garnis, C., Daugaard, M., Guns, E., Hoorfar, M., & Li, I. T. S. (2019) · APL Bioengineering · doi:10.1063/1.5087122 · Cited by 564
Single Particle Tracking: From Theory to Biophysical Applications
Shen, H., Tauzin, L. J., Baiyasi, R., Wang, W., Moringo, N., Shuang, B., & Landes, C. F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00815 · Cited by 536
Fluorescent proteins for live-cell imaging with super-resolution
Nienhaus, K., & Ulrich Nienhaus, G. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60171d · Cited by 337
Hickey, J. W., Neumann, E. K., Radtke, A. J., Camarillo, J. M., Beuschel, R. T., Albanese, A., McDonough, E., Hatler, J., Wiblin, A. E., Fisher, J., et al. (2022) · Nature Methods · doi:10.1038/s41592-021-01316-y · Cited by 311
Magnetic separation techniques in sample preparation for biological analysis: A review
He, J., Huang, M., Wang, D., Zhang, Z., & Li, G. (2014) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2014.04.017 · Cited by 275
Benzothiadiazole Derivatives as Fluorescence Imaging Probes: Beyond Classical Scaffolds
Neto, B. A. D., Carvalho, P. H. P. R., & Correa, J. R. (2015) · Accounts of Chemical Research · doi:10.1021/ar500468p · Cited by 275
Biology and medicine in the landscape of quantum advantages
Cordier, B. A., Sawaya, N. P. D., Guerreschi, G. G., & McWeeney, S. K. (2022) · Journal of The Royal Society Interface · doi:10.1098/rsif.2022.0541 · Cited by 87
“Green fluorescent protein (GFP), for example, is a commonly used marker that allows one to study the expression, localization, and activity of proteins in cells via microscopy [302, 303].”
BackgroundYang, X., Liang, Y., Li, K., Hu, Q., He, J., & Xie, J. (2025) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.4c11399 · Cited by 36
Metadata
- Authors
- Leung, B. O., & Chou, K. C.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2011-09-01
- Volume
- 65
- Issue
- 9
- Pages
- 967-980
- ISSN
- 0003-7028 (ISSN-L)
- OpenAlex
- W2122359996
- Cited by
- 308
- References
- 0
- FWCI
- 11.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.