Laser-Induced Breakdown Spectroscopy (LIBS), Part II: Review of Instrumental and Methodological Approaches to Material Analysis and Applications to Different Fields
Abstract
The first part of this two-part review focused on the fundamental and diagnostics aspects of laser-induced plasmas, only touching briefly upon concepts such as sensitivity and detection limits and largely omitting any discussion of the vast panorama of the practical applications of the technique. Clearly a true LIBS community has emerged, which promises to quicken the pace of LIBS developments, applications, and implementations. With this second part, a more applied flavor is taken, and its intended goal is summarizing the current state-of-the-art of analytical LIBS, providing a contemporary snapshot of LIBS applications, and highlighting new directions in laser-induced breakdown spectroscopy, such as novel approaches, instrumental developments, and advanced use of chemometric tools. More specifically, we discuss instrumental and analytical approaches (e.g., double- and multi-pulse LIBS to improve the sensitivity), calibration-free approaches, hyphenated approaches in which techniques such as Raman and fluorescence are coupled with LIBS to increase sensitivity and information power, resonantly enhanced LIBS approaches, signal processing and optimization (e.g., signal-to-noise analysis), and finally applications. An attempt is made to provide an updated view of the role played by LIBS in the various fields, with emphasis on applications considered to be unique. We finally try to assess where LIBS is going as an analytical field, where in our opinion it should go, and what should still be done for consolidating the technique as a mature method of chemical analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–221 of 221
Yaroshchyk, P., Death, D. L., & Spencer, S. J. (2010) · Applied Spectroscopy · doi:10.1366/000370210793561600 · Cited by 28
Radziemski, L. J., Cremers, D. A., Bostian, M. L., Chinni, R. C., & Navarro-Northrup, C. (2007) · Applied Spectroscopy · doi:10.1366/000370207782597166 · Cited by 27
Giacomo, A. D. (2011) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2011.09.003 · Cited by 27
Analysis of Pharmaceutical Tablet Coating Uniformity by Laser-Induced Breakdown Spectroscopy (LIBS)
Dubey, A., Keyvan, G., Hsia, R., Saranteas, K., Brone, D., Misra, T. K., & Muzzio, F. J. (2011) · Journal of Pharmaceutical Innovation · doi:10.1007/s12247-011-9103-9 · Cited by 27
Resonant laser-induced breakdown spectroscopy for analysis of lead traces in copper alloys
Goueguel, C. L., Laville, S., Vidal, F., Chaker, M., & Sabsabi, M. (2011) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c1ja10112a · Cited by 26
Álvarez, R., Quintero, M. C., & Rodero, A. (2004) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2004.02.004 · Cited by 25
A Review of Near‐Field Laser Ablation for High‐Resolution Nanoscale Surface Analysis
Cleveland, D. M., & Michel, R. G. (2008) · Applied Spectroscopy Reviews · doi:10.1080/05704920701829084 · Cited by 25
Yaroshchyk, P., Morrison, R. J. S., Body, D., & Chadwick, B. L. (2004) · Applied Spectroscopy · doi:10.1366/0003702042475592 · Cited by 23
Controlled calibration method for laser induced breakdown spectroscopy
Wang, 汪. L., Zhang, 张. C., & Feng, 冯. Y. (2008) · Chinese Optics Letters · doi:10.3788/col20080601.0005 · Cited by 21
Pace, D. M. D., D’Angelo, C. A., & Bertuccelli, G. (2011) · Applied Spectroscopy · doi:10.1366/11-06348 · Cited by 20
Kaski, S., Häkkänen, H., & Korppi‐Tommola, J. (2003) · Applied Optics · doi:10.1364/ao.42.006036 · Cited by 19
Roberts, D. E., du Plessis, A., Steyn, J., Botha, L. R., Strydom, C. A., & van Rooyen, I. J. (2010) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2010.09.001 · Cited by 18
Lasers in the Conservation of Artworks
Nimmrichter, J., Kautek, W., & Schreiner, M. (2007) · Springer eBooks · doi:10.1007/978-3-540-72130-7 · Cited by 18
Son, J. G., Choi, S., Oh, M., Kang, H., Suk, H., & Lee, Y. (2010) · Applied Spectroscopy · doi:10.1366/000370210793334963 · Cited by 15
Laser-induced breakdown spectroscopy analysis of asbestos
Caneve, L., Colao, F., Fabbri, F., et al. (2005) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2005.05.014 · Cited by 15
Spectroscopic investigation of laser–water interaction beyond the breakdown threshold energy
Giacomo, A. D., Dell’Aglio, M., Pascale, O. D., & Capitelli, M. (2007) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2007.01.002 · Cited by 14
Senesi, N., Benedetti, P. A., Cristoforetti, G., Legnaioli, S., & Palleschi, V. (2010) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2010.05.010 · Cited by 14
Tognoni, E., Hidalgo, M., Canals, A., Cristoforetti, G., Legnaioli, S., & Palleschi, V. (2009) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b822740c · Cited by 13
Stoichiometry study of laser produced plasma by optical emission spectroscopy
Nouvellon, C., Chaleard, C., Lacour, J. L., & Mauchien, P. (1999) · Applied Surface Science · doi:10.1016/s0169-4332(98)00494-2 · Cited by 11
Near-threshold laser-induced sputtering of aluminum surface by UV and IR irradiation
Burakov, V. S., Bokhonov, A. F., Nedelko, M. I., & Тарасенко, Н. В. (1999) · Applied Surface Science · doi:10.1016/s0169-4332(98)00575-3 · Cited by 9
Taschuk, M. T., Cravetchi, I. V., Tsui, Y. Y., & Fedosejevs, R. (2007) · Elsevier eBooks · doi:10.1016/b978-044451734-0.50011-9 · Cited by 6
Cited by
Near infrared spectroscopy: A mature analytical technique with new perspectives – A review
Pasquini, C. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.04.004 · Cited by 1,153
Laser-Induced Breakdown Spectroscopy
Fortes, F. J., Moros, J., Lucena, P., Cabalín, L. M., & Laserna, J. J. (2013) · Analytical Chemistry · doi:10.1021/ac303220r · Cited by 940
Wiens, R. C., Maurice, S., Lasue, J., Forni, O., Anderson, R. B., Clegg, S., Bender, S., Blaney, D., Barraclough, B. L., Cousin, A., et al. (2013) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2013.02.003 · Cited by 328
Good practices in LIBS analysis: Review and advices
El Haddad, J., Canioni, L., & Bousquet, B. (2014) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2014.08.039 · Cited by 307
Femtosecond laser-induced breakdown spectroscopy
Labutin, T. A., Lednev, V. N., Ilyin, A. A., & Popov, A. M. (2016) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c5ja00301f · Cited by 280
Metadata
- Authors
- Hahn, D. W., & Omenetto, N.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2012-04
- Volume
- 66
- Issue
- 4
- Pages
- 347-419
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2120620624
- Cited by
- 1,497
- References
- 221
- FWCI
- 110.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.