The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Visible, Near-Infrared, and Mid-Infrared Spectroscopy Applications for Soil Assessment with Emphasis on Soil Organic Matter Content and Quality: State-of-the-Art and Key Issues
Open accessAbstract
Visible near-infrared (Vis-NIR) reflection spectroscopy and mid-infrared (mid-IR) reflection spectroscopy are cost- and time-effective and environmentally friendly techniques that could be alternatives to conventional soil analysis methods. Successful determination of spectrally active soil components, including soil organic matter (SOM), depends on the selection of suitable pretreatment and multivariate calibration techniques. The objective of the present review is to critically examine the suitability of Vis-NIR (350–2500 nm) and mid-IR (4000–400 cm−1) spectroscopy as a tool for SOM quantity and quality determination. Particular attention is paid to different pretreatment and calibration procedures and methods, and their ability to predict SOM content from Vis-NIR and mid-IR data is discussed. We then review the most recent research using spectroscopy in different calibration scales (local, regional, or global). Finally, accuracy and robustness, as well as uncertainty in Vis-NIR and mid-IR spectroscopy, are considered. We conclude that spectroscopy, especially the mid-IR technique in association with Savitzky–Golay smoothing and derivatization and the least squares support vector machine (LS-SVM) algorithm, can be useful in determining SOM quantity and quality. Future research conducted for the standardization of protocols and soil conditions will allow more accurate and reliable results on a global and international scale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nondestructive measurement of fruit and vegetable quality by means of NIR spectroscopy: A review
Nicolaï, B. M., Beullens, K., Bobelyn, E., Peirs, A., Saeys, W., Theron, K. I., & Lammertyn, J. (2007) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2007.06.024 · Cited by 2,252
Visible and near infrared spectroscopy in soil science
Stenberg, B., Viscarra Rossel, R. A., Mouazen, A. M., & Wetterlind, J. (2010) · Advances in Agronomy · doi:10.1016/s0065-2113(10)07005-7 · Cited by 1,549
Assessment and monitoring of soil quality using near-infrared reflectance spectroscopy (NIRS)
Cécillon, L., Barthès, B. G., Gomez, C., Ertlen, D., Genot, V., Hedde, M., Stevens, A., & Brun, J. J. (2009) · European Journal of Soil Science · doi:10.1111/j.1365-2389.2009.01178.x · Cited by 247
Cited by
Near infrared spectroscopy: A mature analytical technique with new perspectives – A review
Pasquini, C. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.04.004 · Cited by 1,153
Remote Sensing Techniques for Soil Organic Carbon Estimation: A Review
Angelopoulou, T., Tziolas, N., Balafoutis, A., Zalidis, G., & Bochtis, D. (2019) · Remote Sensing · doi:10.3390/rs11060676 · Cited by 382
Metadata
- Authors
- Gholizadeh, A., Borůvka, L., Saberioon, M., & Vašát, R.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2013-12
- Volume
- 67
- Issue
- 12
- Pages
- 1349-1362
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2082950852
- Cited by
- 196
- References
- 3
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.