The DOI matches its Crossref record.
Simultaneous Visualization of Multiple Antigens with Tyramide Signal Amplification using Antibodies from the same Species
Open accessAbstract
After immunohistochemistry (IHC) began to be used routinely, a number of investigators worked on methods for staining multiple molecules in the same tissue sections or cells. Achieving this goal was not easy, however. One reason for this is that the majority of primary antibodies used in IHC reactions are raised in rabbits, and recognizing signals from two different rabbit antibodies is not trivial. Thus, all of the protocols described to date have serious limitations. Here we report a simple, quick, and inexpensive solution to the problem. It has two major advantages over existing methods. First, by using antibodies from the same host, two or more antigens can be visualized in the same section with commercially available fluorescent dyes. Second, because the technique relies on signal amplification, both rare and abundant antigens can be detected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cassetta, L., Fragkogianni, S., Sims, A. H., Swierczak, A., Forrester, L. M., Zhang, H., Soong, D. Y. H., Cotechini, T., Anur, P., Lin, E. Y., et al. (2019) · Cancer Cell · doi:10.1016/j.ccell.2019.02.009 · Cited by 920
Stack, E. C., Wang, C., Roman, K. A., & Hoyt, C. C. (2014) · Methods · doi:10.1016/j.ymeth.2014.08.016 · Cited by 768
Spatial omics and multiplexed imaging to explore cancer biology
Lewis, S. M., Asselin-Labat, M.-L., Nguyen, Q., Berthelet, J., Tan, X., Wimmer, V. C., Merino, D., Rogers, K. L., & Naik, S. H. (2021) · Nature Methods · doi:10.1038/s41592-021-01203-6 · Cited by 619
Highly multiplexed imaging of single cells using a high-throughput cyclic immunofluorescence method
Lin, J.-R., Fallahi-Sichani, M., & Sorger, P. K. (2015) · Nature Communications · doi:10.1038/ncomms9390 · Cited by 562
Lennerz, J. K., Rühle, V., Ceppa, E. P., Neuhuber, W. L., Bunnett, N. W., Grady, E. F., & Messlinger, K. (2008) · Journal of Comparative Neurology · doi:10.1002/cne.21607 · Cited by 325
Metadata
- Authors
- Tóth, Z. E., & Mezey, É.
- Venue
- Journal of Histochemistry & Cytochemistry
- Publisher
- SAGE Publications
- Published
- 2007-06
- Volume
- 55
- Issue
- 6
- Pages
- 545-554
- ISSN
- 0022-1554 (ISSN-L)
- 1551-5044
- OpenAlex
- W2110278085
- Cited by
- 209
- References
- 0
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous Visualization of Multiple Antigens with Tyramide Signal Amplification using Antibodies from the same Species. https://app.cochat.ai/papers/10.1369/jhc.6a7134.2007
- The paper
- Tóth, Z. E., & Mezey, É. (2007). Simultaneous Visualization of Multiple Antigens with Tyramide Signal Amplification using Antibodies from the same Species. Journal of Histochemistry & Cytochemistry. https://doi.org/10.1369/jhc.6a7134.2007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.