Dynamical model of the CLC-2 ion channel reveals conformational changes associated with selectivity-filter gating
Open accessPublished version of a preprint
Abstract
Abstract This work reports a dynamical Markov state model of CLC-2 “fast” (pore) gating, based on 600 microseconds of molecular dynamics (MD) simulation. In the starting conformation of our CLC-2 model, both outer and inner channel gates are closed. The first conformational change in our dataset involves rotation of the inner-gate backbone along residues S168-G169-I170. This change is strikingly similar to that observed in the cryo-EM structure of the bovine CLC-K channel, though the volume of the intracellular (inner) region of the ion conduction pathway is further expanded in our model. From this state (inner gate open and outer gate closed), two additional states are observed, each involving a unique rotameric flip of the outer-gate residue GLU ex . Both additional states involve conformational changes that orient GLU ex away from the extracellular (outer) region of the ion conduction pathway. In the first additional state, the rotameric flip of GLU ex results in an open, or near-open, channel pore. The equilibrium population of this state is low ( ∼ 1%), consistent with the low open probability of CLC-2 observed experimentally in the absence of a membrane potential stimulus (0 mV). In the second additional state, GLU ex rotates to occlude the channel pore. This state, which has a low equilibrium population ( ∼ 1%), is only accessible when GLU ex is protonated. Together, these pathways model the opening of both an inner and outer gate within the CLC-2 selectivity filter, as a function of GLU ex protonation. Collectively, our findings are consistent with published experimental analyses of CLC-2 gating and provide a high-resolution structural model to guide future investigations. Author summary In the brain, the roles and mechanisms of sodium-, potassium-, and calcium-selective ion channels are well established. In contrast, chloride-selective channels have been studied much less and are not sufficiently understood, despite known associations of chloride-channel defects with brain disorders. The most broadly expressed voltage-activated chloride channel in the brain is CLC-2 (one of 9 human CLC homologs). In this work, we use simulations to model the conformational dynamics of the CLC-2 chloride ion channel selectivity filter (SF), which is the part of the protein that controls whether the channel is in an ion-conducting or non-conducting state. Our analysis identifies four primary conformational states and a specific progression through these states. Our results are consistent with structural and functional data in the literature and provide a high-resolution model for guiding further studies of CLC-2. These results will inform our understanding of how CLC-2 governs electrical activity and ion homeostasis in the brain.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Identification of slow molecular order parameters for Markov model construction
Pérez-Hernández, G., Paul, F., Giorgino, T., De Fabritiis, G., & Noé, F. (2013) · The Journal of Chemical Physics · doi:10.1063/1.4811489 · Cited by 990 · see citing works
Markov state models of biomolecular conformational dynamics
Chodera, J. D., & Noé, F. (2014) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2014.04.002 · Cited by 776 · see citing works
Schwantes, C. R., & Pande, V. S. (2013) · Journal of Chemical Theory and Computation · doi:10.1021/ct300878a · Cited by 597 · see citing works
Self-citation
Flagged first, then by citations
- Authors
- McKiernan, K. A., Koster, A. K., Maduke, M., & Pande, V. S.
- Affiliations
- Stanford University (US)
- Corresponding author
- McKiernan, Keri A.
- Venue
- PLOS Computational Biology
- Publisher
- Public Library of Science (PLoS)
- Published
- 2020-03-30
- Volume
- 16
- Issue
- 3
- Pages
- e1007530
- ISSN
- 1553-734X (ISSN-L)
- 1553-7358
- PMC
- PMC7145265
- OpenAlex
- W3013783484
- Cited by
- 12
- References
- 3
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 3 · 2022: 1 · 2021: 2 · 2020: 2 · 2019: 1
- FWCI
- 0.65
- Type
- journal article
- Language
- en
- Update notices
- new_version (2020-04-09)
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS Computational Biology (publishedVersion, cc-by)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- National Institutes of Health (AI109662, 2R01GM062868)
- National Institute of General Medical Sciences (R01GM113195)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion channel regulation and function
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Protein Structure and Dynamics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion Transport and Channel Regulation
- Keywords
- selectivity filter, conformational change, Markov state models, ion conduction pathway, open probability
- MeSH terms
- CLC-2 Chloride Channels, Animals, Cattle, Chlorides, Kinetics, Markov Chains, Membrane Potentials, Models, Biological, Molecular Conformation, Mutation, Ion Channel Gating, Chloride Channels, Computational Biology, Molecular Dynamics Simulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review