Assessing parameter identifiability of a hemodynamics PDE model using spectral surrogates and dimension reduction
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Computational inverse problems for biomedical simulators suffer from limited data and relatively high parameter dimensionality. This often requires sensitivity analysis, where parameters of the model are ranked based on their influence on the specific quantities of interest. This is especially important for simulators used to build medical digital twins, as the amount of data is typically limited. For expensive models, such as blood flow models, emulation is employed to expedite the simulation time. Parameter ranking and fixing using sensitivity analysis are often heuristic, though, and vary with the specific application or simulator used. The present study provides an innovative solution to this problem by leveraging polynomial chaos expansions (PCEs) for both multioutput global sensitivity analysis and formal parameter identifiability. For the former, we use dimension reduction to efficiently quantify time-series sensitivity of a one-dimensional pulmonary hemodynamics model. We consider both Windkessel and Structured Tree boundary conditions. We then use PCEs to construct univariate profile-likelihood confidence intervals and show how changes in experimental design improve identifiability. Our work presents a novel approach to determining parameter identifiability and leverages a common emulation strategy for enabling profile-likelihood analysis in problems governed by partial differential equations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For more intensive methods, such as synthetic data checks and profile-likelihood, emulators may be needed for more computationally expensive models (Colebank, 2025).”
From Think before you fit: Parameter identifiability, sensitivity and uncertainty in systems biology models (2025) · cites this paper as Colebank, 2025
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gaussian process emulation of dynamic computer codes
Conti, S., Gosling, J. P., Oakley, J. E., & O'Hagan, A. (2009) · Biometrika · doi:10.1093/biomet/asp028 · Cited by 195
Colebank, M. J., & Chesler, N. C. (2022) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1010017 · Cited by 24
Self-citation
Research works printed but not linked: 38
- LM Kimpton, 2025, Challenges and opportunities in uncertainty quantification for healthcare and biological systems, Philos Trans A Math Phys Eng Sci, 383, 20240232
- MJ Colebank, 2024, Guidelines for mechanistic modeling and analysis in cardiovascular research, American Journal of Physiology-Heart and Circulatory Physiology, 327, 10.1152/ajpheart.00766.2023 · DOI
- VG Eck, 2016, A guide to uncertainty quantification and sensitivity analysis for cardiovascular applications, International Journal for Numerical Methods in Biomedical Engineering, 32
- Smith RC. Uncertainty quantification: theory, implementation, and applications. 2024. · doi:10.1137/1.9781611977844
- E Borgonovo, 2016, Sensitivity analysis: A review of recent advances, European Journal of Operational Research, 248, 869, 10.1016/j.ejor.2015.06.032 · DOI · Paper page
- A Alexanderian, 2020, Variance-based sensitivity analysis for time-dependent processes, Reliability Engineering & System Safety, 196, 106722, 10.1016/j.ress.2019.106722 · DOI
- JB Nagel, 2020, Principal component analysis and sparse polynomial chaos expansions for global sensitivity analysis and model calibration: Application to urban drainage simulation, Reliability Engineering & System Safety, 195, 106737, 10.1016/j.ress.2019.106737 · DOI
- VG Eck, 2017, Effects of arterial wall models and measurement uncertainties on cardiovascular model predictions, J Biomech, 50, 188, 10.1016/j.jbiomech.2016.11.042 · DOI
- W Huberts, 2014, Applicability of the polynomial chaos expansion method for personalization of a cardiovascular pulse wave propagation model, Int J Numer Method Biomed Eng, 30, 1679, 10.1002/cnm.2695 · DOI
- MJ Colebank, 2024, Efficient uncertainty quantification in a spatially multiscale model of pulmonary arterial and venous hemodynamics, Biomech Model Mechanobiol, 23, 1909, 10.1007/s10237-024-01875-x · DOI
- F-G Wieland, 2021, On structural and practical identifiability, Current Opinion in Systems Biology, 25, 60, 10.1016/j.coisb.2021.03.005 · DOI · Paper page
- MJ Simpson, 2023, Profile-wise analysis: a profile likelihood-based workflow for identifiability analysis, estimation, and prediction with mechanistic mathematical models, PLoS Comput Biol, 19, 10.1371/journal.pcbi.1011515 · DOI
- M Renardy, 2022, Structural identifiability analysis of age-structured PDE epidemic models, J Math Biol, 84, 9, 10.1007/s00285-021-01711-1 · DOI
- RJ Murphy, 2024, Implementing measurement error models with mechanistic mathematical models in a likelihood-based framework for estimation, identifiability analysis and prediction in the life sciences, J R Soc Interface, 21, 20230402, 10.1098/rsif.2023.0402 · DOI
- M-V Ciocanel, 2024, Parameter identifiability in PDE models of fluorescence recovery after photobleaching, Bulletin of Mathematical Biology, 86, 36, 10.1007/s11538-024-01266-4 · DOI
- M Renardy, 2021, To Sobol or not to Sobol? The effects of sampling schemes in systems biology applications., Mathematical biosciences, 108593, 10.1016/j.mbs.2021.108593 · DOI
- LM Paun, 2021, Emulation-accelerated Hamiltonian Monte Carlo algorithms for parameter estimation and uncertainty quantification in differential equation models, Stat Comput, 32
- R Boiger, 2016, Integration based profile likelihood calculation for PDE constrained parameter estimation problems, Inverse Problems, 32, 125009, 10.1088/0266-5611/32/12/125009 · DOI
- MJ Simpson, 2020, Practical parameter identifiability for spatio-temporal models of cell invasion, J R Soc Interface, 17, 20200055, 10.1098/rsif.2020.0055 · DOI
- LM Paun, 2025, A comparison of Gaussian processes and polynomial chaos emulators in the context of haemodynamic pulse-wave propagation modelling, Philos Trans A Math Phys Eng Sci, 383, 20240222
- MS Olufsen, 2000, Numerical simulation and experimental validation of blood flow in arteries with structured-tree outflow conditions, Annals of Biomedical Engineering, 28, 1281, 10.1114/1.1326031 · DOI · Paper page
- J Colebank, 2021, Sensitivity analysis and uncertainty quantification of 1-D models of pulmonary hemodynamics in mice under control and hypertensive conditions, International Journal for Numerical Methods in Biomedical Engineering, 37, 1, 10.1002/cnm.3242 · DOI
- LM Paun, 2020, Assessing model mismatch and model selection in a Bayesian uncertainty quantification analysis of a fluid-dynamics model of pulmonary blood circulation, Journal of The Royal Society Interface, 17, 20200886, 10.1098/rsif.2020.0886 · DOI
- FN van de Vosse, 2011, Pulse wave propagation in the arterial tree, Annu Rev Fluid Mech, 43, 467, 10.1146/annurev-fluid-122109-160730 · DOI · Paper page
- M Qureshi, 2014, Numerical simulation of blood flow and pressure drop in the pulmonary arterial and venous circulation, Biomechanics and Modeling in Mechanobiology, 13, 1137, 10.1007/s10237-014-0563-y · doi:10.1007/s10237-014-0563-y
- W Yang, 2019, Evolution of hemodynamic forces in the pulmonary tree with progressively worsening pulmonary arterial hypertension in pediatric patients, Biomech Model Mechanobiol, 18, 779, 10.1007/s10237-018-01114-0 · DOI
- N Westerhof, 2009, The arterial windkessel, Medical & Biological Engineering & Computing, 47, 131, 10.1007/s11517-008-0359-2 · DOI · Paper page
- MJ Chambers, 2020, Structural and hemodynamic properties of murine pulmonary arterial networks under hypoxia-induced pulmonary hypertension, Proc Inst Mech Eng H, 234, 1312, 10.1177/0954411920944110 · DOI
- Marelli S, Sudret B. UQLab: a framework for uncertainty quantification in Matlab. 2014:2554–63. · DOI · Paper page
- D Higdon, 2008, Computer model calibration using high-dimensional output, Journal of the American Statistical Association, 103, 570, 10.1198/016214507000000888 · DOI · Paper page
- WP Donders, 2015, Personalization of models with many model parameters: an efficient sensitivity analysis approach, Int J Numer Method Biomed Eng, 31, 10.1002/cnm.2727 · DOI
- A Melis, 2017, Bayesian sensitivity analysis of a 1D vascular model with Gaussian process emulators, Int J Numer Method Biomed Eng, 33, 10.1002/cnm.2882 · DOI
- P Perdikaris, 2015, An effective fractal-tree closure model for simulating blood flow in large arterial networks, Annals of Biomedical Engineering
- MS Olufsen, 2012, Rarefaction and blood pressure in systemic and pulmonary arteries, J Fluid Mech, 705, 280, 10.1017/jfm.2012.220 · doi:10.1017/jfm.2012.220
- AM Taylor-LaPole, 2025, Parameter selection and optimization of a computational network model of blood flow in single-ventricle patients, Journal of the Royal Society Interface, 22
- M Qureshi, 2019, Hemodynamic assessment of pulmonary hypertension in mice: a model-based analysis of the disease mechanism, Biomechanics and Modeling in Mechanobiology, 18, 219, 10.1007/s10237-018-1078-8 · DOI
- A Alexanderian, 2021, Optimal experimental design for infinite-dimensional Bayesian inverse problems governed by PDEs: a review, Inverse Problems, 37, 043001, 10.1088/1361-6420/abe10c · DOI
- S Conti, 2010, Bayesian emulation of complex multi-output and dynamic computer models, Journal of Statistical Planning and Inference, 140, 640, 10.1016/j.jspi.2009.08.006 · DOI · Paper page
Cited by
Preston, S. P., Wilkinson, R. D., Clayton, R. H., Chappell, M. J., & Mirams, G. R. (2025) · Current Opinion in Systems Biology · doi:10.1016/j.coisb.2025.100563 · Cited by 11
Metadata
- Authors
- Colebank, M. J.
- ORCID
- Colebank, Mitchel J.
- Venue
- PLOS Computational Biology
- Publisher
- Public Library of Science (PLoS)
- Published
- 2025-10-09
- Volume
- 21
- Issue
- 10
- Pages
- e1013553
- ISSN
- 1553-7358
- Cited by
- 5
- References
- 2
- Language
- en
- Update notices
- new_version (2025-10-14)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.