Sensitivity of Noninvasive Prenatal Detection of Fetal Aneuploidy from Maternal Plasma Using Shotgun Sequencing Is Limited Only by Counting Statistics
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
We recently demonstrated noninvasive detection of fetal aneuploidy by shotgun sequencing cell-free DNA in maternal plasma using next-generation high throughput sequencer. However, GC bias introduced by the sequencer placed a practical limit on the sensitivity of aneuploidy detection. In this study, we describe a method to computationally remove GC bias in short read sequencing data by applying weight to each sequenced read based on local genomic GC content. We show that sensitivity is limited only by counting statistics and that sensitivity can be increased to arbitrary precision in sample containing arbitrarily small fraction of fetal DNA simply by sequencing more DNA molecules. High throughput shotgun sequencing of maternal plasma DNA should therefore enable noninvasive diagnosis of any type of fetal aneuploidy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“However, concomitant analysis of normalized coverage in batches of samples appears to circumvent the need for adjustment for GC content (32), allowing more accurate detection of segmental losses.”
From Carrier testing for severe childhood recessive diseases by next-generation sequencing (2011) · cites this paper as [32]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lo, Y. M. D., Tein, M. S. C., Lau, T. K., Haines, C. J., Leung, T. N., Poon, P. M. K., Wainscoat, J. S., Johnson, P. J., Chang, A. M. Z., & Hjelm, N. M. (1998) · The American Journal of Human Genetics · doi:10.1086/301800 · Cited by 1,653 · cited 1×
“As fetal DNA fraction varies in different pregnancies and in different stages of a pregnancy [11], clinical studies would be needed to determine the minimum fetal DNA fraction and thus the general sequencing depth required.”
BackgroundNoninvasive diagnosis of fetal aneuploidy by shotgun sequencing DNA from maternal blood
Fan, H. C., Blumenfeld, Y. J., Chitkara, U., Hudgins, L., & Quake, S. R. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0808319105 · Cited by 1,114 · cited 4×
“Such deviation, caused largely by GC bias in the sequencing data, placed a practical limit on the sensitivity of the test especially for detecting aneuploidy associated with chromosomes that are GC-poor or GC-rich [3].”
BackgroundResultInfluentialSelf-citationSubstantial biases in ultra-short read data sets from high-throughput DNA sequencing
Dohm, J. C., Lottaz, C., Borodina, T., & Himmelbauer, H. (2008) · Nucleic Acids Research · doi:10.1093/nar/gkn425 · Cited by 1,088 · cited 1×
“Others have shown the existence of substantial GC bias in Illumina/Solexa and ABI/ SOLiD sequencing [5,8,9,10], and this limits the sensitivity of the detection of under- or over-representation of chromosomes.”
BackgroundChiu, R. W. K., Chan, K. C. A., Gao, Y., Lau, V. Y. M., Zheng, W., Leung, T. Y., Foo, C. H. F., Xie, B., Tsui, N. B. Y., Lun, F. M. F., et al. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810641105 · Cited by 942 · cited 1×
“Our results were quickly reproduced by an independent group [4,5], which used a slightly different statistical approach in determining the representation of chromosomes.”
ResultHigh-resolution mapping of copy-number alterations with massively parallel sequencing
Chiang, D. Y., Getz, G., Jaffe, D. B., O'Kelly, M. J. T., Zhao, X., Carter, S. L., Russ, C., Nusbaum, C., Meyerson, M., & Lander, E. S. (2009) · Nature Methods · doi:10.1038/nmeth.1276 · Cited by 510
ACOG Practice Bulletin No. 88: Invasive Prenatal Testing for Aneuploidy
(2007) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000291570.63450.44 · Cited by 303
Prenatal diagnosis: progress through plasma nucleic acids
Dennis Lo, Y. M., & Chiu, R. W. K. (2007) · Nature Reviews Genetics · doi:10.1038/nrg1982 · Cited by 199
Chiu, R. W. K., Sun, H., Akolekar, R., Clouser, C. R., Lee, C. C., McKernan, K. J., Zhou, D., Nicolaides, K. H., & Lo, Y. M. D. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2009.136507 · Cited by 139 · cited 2×
“Our results were quickly reproduced by an independent group [4,5], which used a slightly different statistical approach in determining the representation of chromosomes.”
BackgroundResultGuibert, J., Benachi, A., Grebille, A.-G., Ernault, P., Zorn, J.-R., & Costa, J.-M. (2003) · Human Reproduction · doi:10.1093/humrep/deg320 · Cited by 135 · cited 1×
“Since there are measurable amounts of fetal DNA in maternal plasma as early as day 18 after embryo transfer by assisted reproduction [6], this suggests that it may be possible to perform noninvasive prenatal diagnosis for fetal aneuploidy as early as desired in the pregnancy, and potentially at the first doctor’s visi…”
BackgroundIsochore chromosome maps of the human genome
Oliver, J. L. T., Carpena, P., Román-Roldán, R., Mata‐Balaguer, T., Mejías-Romero, A., Hackenberg, M., & Bernaola‐Galván, P. (2002) · Gene · doi:10.1016/s0378-1119(02)01034-x · Cited by 68 · cited 1×
“300 kb regions of relatively homogeneous GC content [7], sequenced fragments lying within the isochore would most likely have GC content similar to the isochore.”
Background
Cited by
An ultrasensitive method for quantitating circulating tumor DNA with broad patient coverage
Newman, A. M., Bratman, S. V., To, J., Wynne, J. F., Eclov, N. C. W., Modlin, L. A., Liu, C. L., Neal, J. W., Wakelee, H. A., Merritt, R. E., et al. (2014) · Nature Medicine · doi:10.1038/nm.3519 · Cited by 2,220
Maternal Plasma DNA Sequencing Reveals the Genome-Wide Genetic and Mutational Profile of the Fetus
Lo, Y. M. D., Chan, K. C. A., Sun, H., Chen, E. Z., Jiang, P., Lun, F. M. F., Zheng, Y. W., Leung, T. Y., Lau, T. K., Cantor, C. R., et al. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001720 · Cited by 1,101
“Previous data have suggested that the GC bias affecting the measurement of total DNA in maternal plasma is likely to be an analytical artifact related to the sequencing platform used (6, 7, 10, 11), rather than an indication of the differential representation of DNA molecules of different GC content.”
Chiu, R. W. K., Akolekar, R., Zheng, Y. W. L., Leung, T. Y., Sun, H., Chan, K. C. A., Lun, F. M. F., Go, A. T. J. I., Lau, E. T., To, W. W. K., et al. (2011) · BMJ · doi:10.1136/bmj.c7401 · Cited by 774
“More research is required to develop protocols to improve the precision for measuring amount of DNA molecules from chromosomes 18 and 13.”
MethodCarrier testing for severe childhood recessive diseases by next-generation sequencing
Bell, C. J., Dinwiddie, D. L., Miller, N. A., Hateley, S. L., Ganusova, E. E., Mudge, J., Langley, R. J., Zhang, L., Lee, C. C., Schilkey, F. D., et al. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3001756 · Cited by 706
“However, concomitant analysis of normalized coverage in batches of samples appears to circumvent the need for adjustment for GC content (32), allowing more A SOLiD3 SBL Illumina GAIIx SBS”
BackgroundGenome-Wide Fetal Aneuploidy Detection by Maternal Plasma DNA Sequencing
Bianchi, D. W., Platt, L. D., Goldberg, J. D., Abuhamad, A. Z., Sehnert, A. J., & Rava, R. P. (2012) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e31824fb482 · Cited by 644
“two translocation T21 cases arising from Robertsonian translocations, one of which was also mosaic for monosomy X (45,X, 21,der(14;21)q10;q10)[4]/ 46,XY, 21,der(14;21)q10;q10)[17] and 46,XY, 21, der(21;21)q10;q10).”
Background
Metadata
- Authors
- Fan, H. C., & Quake, S. R.
- Affiliations
- Howard Hughes Medical Institute (US)
- Corresponding author
- Quake, Stephen R.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2010-05-03
- Volume
- 5
- Issue
- 5
- Pages
- e10439
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC2862719
- OpenAlex
- W1965411537
- Cited by
- 141
- References
- 11
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 3 · 2023: 3 · 2022: 2 · 2021: 1 · 2020: 3 · 2019: 6 · 2018: 16 · 2017: 10 · 2016: 11 · 2015: 14 · 2014: 19 · 2013: 14 · 2012: 19
- FWCI
- 14.78
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Wallace H. Coulter Foundation
- National Institutes of Health
- Topics
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Prenatal Screening and Diagnostics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genomics and Phylogenetic Studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cancer Research › Cancer Genomics and Diagnostics
- Keywords
- noninvasive prenatal diagnosis, fetal aneuploidy, cell-free DNA, maternal plasma, shotgun sequencing, GC content bias, sequencing sensitivity, counting statistics, fetal fraction
- MeSH terms
- Aneuploidy, Base Composition, Female, Fetus, Humans, Pregnancy, Prenatal Diagnosis, Models, Statistical, Poisson Distribution, Artifacts, Sequence Analysis, DNA
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitivity of Noninvasive Prenatal Detection of Fetal Aneuploidy from Maternal Plasma Using Shotgun Sequencing Is Limited Only by Counting Statistics. https://app.cochat.ai/papers/10.1371/journal.pone.0010439
- The paper
- Fan, H. C., & Quake, S. R. (2010). Sensitivity of Noninvasive Prenatal Detection of Fetal Aneuploidy from Maternal Plasma Using Shotgun Sequencing Is Limited Only by Counting Statistics. PLoS ONE. https://doi.org/10.1371/journal.pone.0010439
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.