CoChat

In Vivo SPECT Reporter Gene Imaging of Regulatory T Cells

Open access
Sharif-Paghaleh, Ehsan, Sunassee, Kavitha, Tavaré, Richard, Ratnasothy, Kulachelvy, Koers, Alexander, Ali, Niwa, Alhabbab, Rowa, Blower, Philip J., Lechler, Robert I., Smyth, Lesley A., Mullen, Gregory E., Lombardi, Giovanna · 2011 · PLoS ONE
Cited by 51

The DOI matches its Crossref record.

Abstract

Regulatory T cells (Tregs) were identified several years ago and are key in controlling autoimmune diseases and limiting immune responses to foreign antigens, including alloantigens. In vivo imaging techniques including intravital microscopy as well as whole body imaging using bioluminescence probes have contributed to the understanding of in vivo Treg function, their mechanisms of action and target cells. Imaging of the human sodium/iodide symporter via Single Photon Emission Computed Tomography (SPECT) has been used to image various cell types in vivo. It has several advantages over the aforementioned imaging techniques including high sensitivity, it allows non-invasive whole body studies of viable cell migration and localisation of cells over time and lastly it may offer the possibility to be translated to the clinic. This study addresses whether SPECT/CT imaging can be used to visualise the migratory pattern of Tregs in vivo. Treg lines derived from CD4(+)CD25(+)FoxP3(+) cells were retrovirally transduced with a construct encoding for the human Sodium Iodide Symporter (NIS) and the fluorescent protein mCherry and stimulated with autologous DCs. NIS expressing self-specific Tregs were specifically radiolabelled in vitro with Technetium-99m pertechnetate ((99m)TcO(4)(-)) and exposure of these cells to radioactivity did not affect cell viability, phenotype or function. In addition adoptively transferred Treg-NIS cells were imaged in vivo in C57BL/6 (BL/6) mice by SPECT/CT using (99m)TcO(4)(-). After 24 hours NIS expressing Tregs were observed in the spleen and their localisation was further confirmed by organ biodistribution studies and flow cytometry analysis. The data presented here suggests that SPECT/CT imaging can be utilised in preclinical imaging studies of adoptively transferred Tregs without affecting Treg function and viability thereby allowing longitudinal studies within disease models.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0025857

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 51

Metadata

Authors
Sharif-Paghaleh, E., Sunassee, K., Tavaré, R., Ratnasothy, K., Koers, A., Ali, N., Alhabbab, R., Blower, P. J., Lechler, R. I., Smyth, L. A., Mullen, G. E., & Lombardi, G.
Venue
PLoS ONE
Published
2011-10-17
Volume
6
Issue
10
Pages
e25857
ISSN
1932-6203 (ISSN-L)
OpenAlex
W1987282023
Cited by
51
References
0
FWCI
1.23
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In Vivo SPECT Reporter Gene Imaging of Regulatory T Cells. https://app.cochat.ai/papers/10.1371/journal.pone.0025857
The paper
Sharif-Paghaleh, E., Sunassee, K., Tavaré, R., Ratnasothy, K., Koers, A., Ali, N., Alhabbab, R., Blower, P. J., Lechler, R. I., Smyth, L. A., Mullen, G. E., & Lombardi, G. (2011). In Vivo SPECT Reporter Gene Imaging of Regulatory T Cells. PLoS ONE. https://doi.org/10.1371/journal.pone.0025857

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.