The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
FilmArray, an Automated Nested Multiplex PCR System for Multi-Pathogen Detection: Development and Application to Respiratory Tract Infection
Open accessAbstract
The ideal clinical diagnostic system should deliver rapid, sensitive, specific and reproducible results while minimizing the requirements for specialized laboratory facilities and skilled technicians. We describe an integrated diagnostic platform, the “FilmArray”, which fully automates the detection and identification of multiple organisms from a single sample in about one hour. An unprocessed biologic/clinical sample is subjected to nucleic acid purification, reverse transcription, a high-order nested multiplex polymerase chain reaction and amplicon melt curve analysis. Biochemical reactions are enclosed in a disposable pouch, minimizing the PCR contamination risk. FilmArray has the potential to detect greater than 100 different nucleic acid targets at one time. These features make the system well-suited for molecular detection of infectious agents. Validation of the FilmArray technology was achieved through development of a panel of assays capable of identifying 21 common viral and bacterial respiratory pathogens. Initial testing of the system using both cultured organisms and clinical nasal aspirates obtained from children demonstrated an analytical and clinical sensitivity and specificity comparable to existing diagnostic platforms. We demonstrate that automated identification of pathogens from their corresponding target amplicon(s) can be accomplished by analysis of the DNA melting curve of the amplicon.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Ramers, C. (2000) · JAMA · doi:10.1001/jama.283.20.2680 · Cited by 291
Cited by
Polymerase chain reaction in microfluidic devices
Ahrberg, C. D., Manz, A., & Chung, B. G. (2016) · Lab on a Chip · doi:10.1039/c6lc00984k · Cited by 283
Wootton, S. H., Aguilera, E., Salazar, L., Hemmert, A. C., & Hasbun, R. (2016) · Annals of Clinical Microbiology and Antimicrobials · doi:10.1186/s12941-016-0137-1 · Cited by 65
Expanding Molecular Diagnostics for Central Nervous System Infections
Gutierrez, M., & Emmanuel, P. J. (2018) · Advances in Pediatrics · doi:10.1016/j.yapd.2018.04.005 · Cited by 11
Gaudenzi, G., Kumbakumba, E., Rasti, R., Nanjebe, D., Réu, P., Nyehangane, D., Mårtensson, A., Nassejje, M., Karlsson, J., Mzee, J., et al. (2020) · JMIR Research Protocols · doi:10.2196/21430 · Cited by 9
Metadata
- Authors
- Poritz, M. A., Blaschke, A. J., Byington, C. L., Allen, L., Nilsson, K., Jones, D. E., Thatcher, S. A., Robbins, T., Lingenfelter, B., Amiott, E., Herbener, A., Daly, J., Dobrowolski, S. F., Teng, D. H. F., & Ririe, K. M.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2011-10-19
- Volume
- 6
- Issue
- 10
- Pages
- e26047
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2045855653
- Cited by
- 429
- References
- 3
- FWCI
- 11.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: FilmArray, an Automated Nested Multiplex PCR System for Multi-Pathogen Detection: Development and Application to Respiratory Tract Infection. https://app.cochat.ai/papers/10.1371/journal.pone.0026047
- The paper
- Poritz, M. A., Blaschke, A. J., Byington, C. L., Allen, L., Nilsson, K., Jones, D. E., Thatcher, S. A., Robbins, T., Lingenfelter, B., Amiott, E., Herbener, A., Daly, J., Dobrowolski, S. F., Teng, D. H. F., & Ririe, K. M. (2011). FilmArray, an Automated Nested Multiplex PCR System for Multi-Pathogen Detection: Development and Application to Respiratory Tract Infection. PLoS ONE. https://doi.org/10.1371/journal.pone.0026047
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.