CoChat

Coupled Analysis of In Vitro and Histology Tissue Samples to Quantify Structure-Function Relationship

Open access

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Abstract

The structure/function relationship is fundamental to our understanding of biological systems at all levels, and drives most, if not all, techniques for detecting, diagnosing, and treating disease. However, at the tissue level of biological complexity we encounter a gap in the structure/function relationship: having accumulated an extraordinary amount of detailed information about biological tissues at the cellular and subcellular level, we cannot assemble it in a way that explains the correspondingly complex biological functions these structures perform. To help close this information gap we define here several quantitative temperospatial features that link tissue structure to its corresponding biological function. Both histological images of human tissue samples and fluorescence images of three-dimensional cultures of human cells are used to compare the accuracy of in vitro culture models with their corresponding human tissues. To the best of our knowledge, there is no prior work on a quantitative comparison of histology and in vitro samples. Features are calculated from graph theoretical representations of tissue structures and the data are analyzed in the form of matrices and higher-order tensors using matrix and tensor factorization methods, with a goal of differentiating between cancerous and healthy states of brain, breast, and bone tissues. We also show that our techniques can differentiate between the structural organization of native tissues and their corresponding in vitro engineered cell culture models.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0032227

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Examples of different tissue types and states as well as their representations as cell-graphs.
Figure 1 Examples of different tissue types and states as well as their representations as cell-graphs.CC BY · PubMed Central
Figure 2 Analysis of histology and in vitro data sets using coupled matrix and tensor factorization (CMTF). Time mode is slotted as 0, 1, 2, 4, 6, 10, 16, 24, 72, 120, 168 in hours. Features mode contains the cell graph features: average degree, clustering coefficient C, clustering coefficient D, clustering coefficient E, average eccentricity, diameter, radius, average eccentricity 90, diameter 90, radius 90, average path length, effective hop diameter, hop plot exponent, giant connected component ratio, # connected components, average connected component size, % isolated points, % end points, # central points, % central points, mean, std, skewness, kurtosis, # nodes, # edges. These features are defined in Table S1.
Figure 2 Analysis of histology and in vitro data sets using coupled matrix and tensor factorization (CMTF). Time mode is slotted as 0, 1, 2, 4, 6, 10, 16, 24, 72, 120, 168 in hours. Features mode contains the cell graph features: average degree, clustering coefficient C, clustering coefficient D, clustering coefficient E, average eccentricity, diameter, radius, average eccentricity 90, diameter 90, radius 90, average path length, effective hop diameter, hop plot exponent, giant connected component ratio, # connected components, average connected component size, % isolated points, % end points, # central points, % central points, mean, std, skewness, kurtosis, # nodes, # edges. These features are defined in Table S1.CC BY · PubMed Central
Figure 3 Singular Value Decomposition and R-component CP model.
Figure 3 Singular Value Decomposition and R-component CP model.CC BY · PubMed Central
Figure 4 Three-way and Two-way analysis of in vitro brain tissue data. (a) CP factorization of the tensor with modes: features, samples and time. The 1st component separates the 2 different functional states: cancer (red-triangle sign) from normal (green-plus sign) tissue samples; (b) SVD of matrix of type: features by samples (across all times); (c) features projected over the 1st component of the CP model. Cell-graph features such as % of end points, number of connected components, average connected component size, average path length, average eccentricity are identified as influential in the analysis since their coefficients diverge the most from zero. (Note that we have 23 features on the plot since three features have been identified as outliers and excluded).
Figure 4 Three-way and Two-way analysis of in vitro brain tissue data. (a) CP factorization of the tensor with modes: features, samples and time. The 1st component separates the 2 different functional states: cancer (red-triangle sign) from normal (green-plus sign) tissue samples; (b) SVD of matrix of type: features by samples (across all times); (c) features projected over the 1st component of the CP model. Cell-graph features such as % of end points, number of connected components, average connected component size, average path length, average eccentricity are identified as influential in the analysis since their coefficients diverge the most from zero. (Note that we have 23 features on the plot since three features have been identified as outliers and excluded).CC BY · PubMed Central
Figure 5 Coupled matrix and tensor factorization (CMTF) on in vitro brain samples represented by tensor and histology samples represented by matrix Y (see Figure 2 ). (a) The first column of matrix B, that is the factor matrix corresponding to the in vitro samples mode extracted using CMTF, separates cancer (blue-square signs) from normal (light blue-plus signs) tissue samples; (b) The first column of matrix D, that is the factor matrix corresponding to the histology samples mode extracted using CMTF, can separate cancer (red-triangle sign) from healthy (green-star sign) samples; (c) features captured by the common component extracted by CMTF.
Figure 5 Coupled matrix and tensor factorization (CMTF) on in vitro brain samples represented by tensor and histology samples represented by matrix Y (see Figure 2 ). (a) The first column of matrix B, that is the factor matrix corresponding to the in vitro samples mode extracted using CMTF, separates cancer (blue-square signs) from normal (light blue-plus signs) tissue samples; (b) The first column of matrix D, that is the factor matrix corresponding to the histology samples mode extracted using CMTF, can separate cancer (red-triangle sign) from healthy (green-star sign) samples; (c) features captured by the common component extracted by CMTF.CC BY · PubMed Central
Figure 6 Three-way and two-way analysis of in vitro bone tissue data. (a) CP factorization of the tensor with modes: features, samples and time. Both the 1st and the 2nd components separate the two different functional states: cancer (red-triangle sign) from normal (green-plus sign) tissue samples; (b) SVD of matrix of type: features by samples (across all times); (c) features projected over the 1st component of CP model. Cell-graph features such as % of end points, number of connected components, giant connected component ratio, average path length, average eccentricity are identified as influential in the analysis since their coefficients diverge the most from zero; (d) since the 2nd component can also distinguish between two functional states we also show the 2nd CP component in features mode. Note that the influential features are different in the 2nd component, e.g., while the number of connected components has a high coefficient in the 1st component, its coefficient in the 2nd component is close to 0.
Figure 6 Three-way and two-way analysis of in vitro bone tissue data. (a) CP factorization of the tensor with modes: features, samples and time. Both the 1st and the 2nd components separate the two different functional states: cancer (red-triangle sign) from normal (green-plus sign) tissue samples; (b) SVD of matrix of type: features by samples (across all times); (c) features projected over the 1st component of CP model. Cell-graph features such as % of end points, number of connected components, giant connected component ratio, average path length, average eccentricity are identified as influential in the analysis since their coefficients diverge the most from zero; (d) since the 2nd component can also distinguish between two functional states we also show the 2nd CP component in features mode. Note that the influential features are different in the 2nd component, e.g., while the number of connected components has a high coefficient in the 1st component, its coefficient in the 2nd component is close to 0.CC BY · PubMed Central
Figure 7 Coupled factorization of in vitro bone samples represented by tensor and histology samples represented by matrix Y. (a) Both the 1st and the 2nd column of matrix B extracted by a CMTF model separate cancer (blue-square sign) from normal (light blue-plus sign) samples; (b) Matrix D corresponding to the histology samples mode extracted using a CMTF model is useful to narrow the coupled analysis since only the 1st component can separate cancer (red-triangle sign) from healthy (green-star sign) samples; (c) features captured by the 1st CMTF component.
Figure 7 Coupled factorization of in vitro bone samples represented by tensor and histology samples represented by matrix Y. (a) Both the 1st and the 2nd column of matrix B extracted by a CMTF model separate cancer (blue-square sign) from normal (light blue-plus sign) samples; (b) Matrix D corresponding to the histology samples mode extracted using a CMTF model is useful to narrow the coupled analysis since only the 1st component can separate cancer (red-triangle sign) from healthy (green-star sign) samples; (c) features captured by the 1st CMTF component.CC BY · PubMed Central
Figure 8 Three-way and two-way analysis of in vitro breast tissue data. (a) CP factorization of the tensor with modes: features, samples and time. Only the 2nd component can separate the two different functional states: cancer (red-triangle sign) from normal (green-plus sign) tissue samples; (b) SVD of matrix of type: features by samples (across all times); (c) features projected over the 2nd CP component. Cell-graph features such as % of end points, number of connected components, average connected component size, average path length, average eccentricity are identified as influential in the analysis.
Figure 8 Three-way and two-way analysis of in vitro breast tissue data. (a) CP factorization of the tensor with modes: features, samples and time. Only the 2nd component can separate the two different functional states: cancer (red-triangle sign) from normal (green-plus sign) tissue samples; (b) SVD of matrix of type: features by samples (across all times); (c) features projected over the 2nd CP component. Cell-graph features such as % of end points, number of connected components, average connected component size, average path length, average eccentricity are identified as influential in the analysis.CC BY · PubMed Central
Figure 9 Coupled matrix and tensor factorization on in vitro breast samples represented by tensor and histology samples represented by matrix Y ( Figure 2 ). (a) The 1st column of matrix B corresponding to the in vitro samples mode extracted by a CMTF model can separate cancer (blue-square sign) from normal (light blue-plus sign) tissue samples; (b) Unlike for brain and bone tissues, matrix D corresponding to the histology samples mode extracted using a CMTF model cannot separate cancer samples (red-triangle sign) from healthy (green-star sign) samples; (c) features captured by the common component extracted by CMTF. Cell-graph features identified as influential in the coupled analysis are similar to the features in Figure 5c and 7c with some minor differences.
Figure 9 Coupled matrix and tensor factorization on in vitro breast samples represented by tensor and histology samples represented by matrix Y ( Figure 2 ). (a) The 1st column of matrix B corresponding to the in vitro samples mode extracted by a CMTF model can separate cancer (blue-square sign) from normal (light blue-plus sign) tissue samples; (b) Unlike for brain and bone tissues, matrix D corresponding to the histology samples mode extracted using a CMTF model cannot separate cancer samples (red-triangle sign) from healthy (green-star sign) samples; (c) features captured by the common component extracted by CMTF. Cell-graph features identified as influential in the coupled analysis are similar to the features in Figure 5c and 7c with some minor differences.CC BY · PubMed Central
Figure 10 In vitro vs. histology samples of cancerous tissue (10a Brain, 10b Bone, and 10c Breast samples). The first two components of SVD analysis explain 72.4%, 65.9%, 66.5% of the variance for each tissue type, respectively. SVD yields a linear separation between in vitro and histology cancerous tissue samples. Two clusters (red and green) are very well separated, with few outliers. This defines and quantifies a structural difference between engineered tissues and the native tissues.
Figure 10 In vitro vs. histology samples of cancerous tissue (10a Brain, 10b Bone, and 10c Breast samples). The first two components of SVD analysis explain 72.4%, 65.9%, 66.5% of the variance for each tissue type, respectively. SVD yields a linear separation between in vitro and histology cancerous tissue samples. Two clusters (red and green) are very well separated, with few outliers. This defines and quantifies a structural difference between engineered tissues and the native tissues.CC BY · PubMed Central
Figure 11 In vitro vs. histology samples of normal tissue (11a Brain, 11b Bone, and 11c Breast samples). The first two components of SVD analysis explain 76.5%, 75%, 62.8% of the variance for each tissue type respectively and shows that there is a linear separation of in vitro and native healthy tissue samples. The separation confirms that recreating the complex structural organization of native tissue samples in vitro is difficult.
Figure 11 In vitro vs. histology samples of normal tissue (11a Brain, 11b Bone, and 11c Breast samples). The first two components of SVD analysis explain 76.5%, 75%, 62.8% of the variance for each tissue type respectively and shows that there is a linear separation of in vitro and native healthy tissue samples. The separation confirms that recreating the complex structural organization of native tissue samples in vitro is difficult.CC BY · PubMed Central
Figure 12 In vitro tissue samples remain structurally different from histology samples (blue) over time. We identified no time point in the development of the in vitro samples that is mathematically similar to histology data. (a) Brain cancer cultures vary considerably over time getting very close to the histology samples, demonstrating they best resemble the histology samples. In vitro bone cancer (b) and breast cancer (c) samples remain clustered over all time points and exhibit no mixing of data points with histology data.
Figure 12 In vitro tissue samples remain structurally different from histology samples (blue) over time. We identified no time point in the development of the in vitro samples that is mathematically similar to histology data. (a) Brain cancer cultures vary considerably over time getting very close to the histology samples, demonstrating they best resemble the histology samples. In vitro bone cancer (b) and breast cancer (c) samples remain clustered over all time points and exhibit no mixing of data points with histology data.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 40 references

Research works printed but not linked: 2

  1. SJ Keenan, 2000, An automated machine vision system for the histological grading of cervical intraepithelial neoplasia (CIN)., Journal of Pathology, 192, 351, 10.1002/1096-9896(2000)9999:9999<::aid-path708>3.0.co;2-i · doi:10.1002/1096-9896(2000)9999:9999<::aid-path708>3.0.co;2-i
  2. G Golub, 1996, Matrix Computations, Third Edition

Cited by

See all 36

Metadata

Authors
Acar, E., Plopper, G. E., & Yener, B.
Affiliations
  • University of Copenhagen (DK)
  • Rensselaer Polytechnic Institute (US)
Corresponding author
Yener, Bülent
Venue
PLoS ONE
Published
2012-03-30
Volume
7
Issue
3
Pages
e32227
ISSN
1932-6203 (ISSN-L)
OpenAlex
W1990904097
Cited by
35
References
39
Citations by year
2026: 2 · 2025: 1 · 2024: 2 · 2023: 4 · 2021: 2 · 2020: 2 · 2019: 3 · 2018: 2 · 2017: 2 · 2016: 3 · 2015: 2 · 2014: 4 · 2013: 5 · 2012: 1
FWCI
1.75
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Research at the University of Copenhagen (University of Copenhagen) (publishedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Villum Fonden
  • National Institutes of Health
  • National Institute of Biomedical Imaging and Bioengineering (R01EB008016)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
  • Physical Sciences › Computer Science › Computational Theory and Mathematics › Topological and Geometric Data Analysis
Keywords
structure-function relationship, tissue engineering, in vitro cell culture model, histology, fluorescence imaging, graph theory, matrix factorization, tensor decomposition, cancer detection, brain tissue, breast tissue, bone
MeSH terms
Algorithms, Bone and Bones, Bone Neoplasms, Brain, Breast, Breast Neoplasms, Female, Glioma, Humans, Image Interpretation, Computer-Assisted, Models, Anatomic, Cell Culture Techniques, Imaging, Three-Dimensional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Coupled Analysis of In Vitro and Histology Tissue Samples to Quantify Structure-Function Relationship. https://app.cochat.ai/papers/10.1371/journal.pone.0032227
The paper
Acar, E., Plopper, G. E., & Yener, B. (2012). Coupled Analysis of In Vitro and Histology Tissue Samples to Quantify Structure-Function Relationship. PLoS ONE. https://doi.org/10.1371/journal.pone.0032227

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.