CoChat

Performance Characteristics of the Cepheid Xpert MTB/RIF Test in a Tuberculosis Prevalence Survey

Open access
Dorman, Susan E., Chihota, Violet N., Lewis, James J., Shah, Maunank, Clark, David, Grant, Alison D., Churchyard, Gavin J., Fielding, Katherine L. · 2012 · PLoS ONE
Cited by 65

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Xpert MTB/RIF ("Xpert") is a molecular test for detection of Mycobacterium tuberculosis (MTB) in sputum. Performance characteristics have been established for its use during passive tuberculosis (TB) case detection in symptomatic TB suspects, but Xpert performance has not been assessed in other settings. Objectives were to determine Xpert performance and costs in the context of a TB prevalence survey. METHODOLOGY/PRINCIPAL FINDINGS: This was a diagnostic sub-study of a TB prevalence survey conducted in gold mining companies in South Africa. Sputa (one per participant) were tested using smear microscopy, liquid culture (reference comparator), and Xpert. Costs were collected using an ingredients approach and analyzed using a public health program perspective. 6893 participants provided a sputum specimen. 187/6893 (2.7%) were positive for MTB in culture, 144/6893 (2.1%) were positive for MTB by Xpert, and 91/6893 (1.3%) were positive for acid fast bacilli by microsocopy. Sensitivity, specificity, positive predictive value, and negative predictive value for detection of MTB by Xpert were 62.6% (95% confidence interval [CI] 55.2, 69.5), 99.6% (99.4, 99.7), 81.3% (73.9, 87.3), and 98.9 (98.6, 98.8); agreement between Xpert and culture was 98.5% (98.2, 98.8). Sensitivity of microscopy was 17.6% (12.5, 23.9). When individuals with a history of TB treatment were excluded from the analysis, Xpert specificity was 99.8 (99.7, 99.9) and PPV was 90.6 (83.3, 95.4) for detection of MTB. For the testing scenario of 7000 specimens with 2.7% of specimens culture positive for MTB, costs were $165,690 for Xpert and $115,360 for the package of microscopy plus culture. CONCLUSION: In the context of a TB prevalence survey, the Xpert diagnostic yield was substantially higher than that of microscopy yet lower than that of liquid culture. Xpert may be useful as a sole test for TB case detection in prevalence surveys, particularly in settings lacking capacity for liquid culture.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0043307

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 65

Metadata

Authors
Dorman, S. E., Chihota, V. N., Lewis, J. J., Shah, M., Clark, D., Grant, A. D., Churchyard, G. J., & Fielding, K. L.
Venue
PLoS ONE
Published
2012-08-15
Volume
7
Issue
8
Pages
e43307
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2147588959
Cited by
65
References
3
FWCI
5.67
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance Characteristics of the Cepheid Xpert MTB/RIF Test in a Tuberculosis Prevalence Survey. https://app.cochat.ai/papers/10.1371/journal.pone.0043307
The paper
Dorman, S. E., Chihota, V. N., Lewis, J. J., Shah, M., Clark, D., Grant, A. D., Churchyard, G. J., & Fielding, K. L. (2012). Performance Characteristics of the Cepheid Xpert MTB/RIF Test in a Tuberculosis Prevalence Survey. PLoS ONE. https://doi.org/10.1371/journal.pone.0043307

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.