Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 208

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Quantification of Reverse Transcriptase Activity by Real-Time PCR as a Fast and Accurate Method for Titration of HIV, Lenti- and Retroviral Vectors

Open access
Vermeire, Jolien, Naessens, Evelien, Vanderstraeten, Hanne, Landi, Alessia, Iannucci, Veronica, Van Nuffel, Anouk, Taghon, Tom, Pizzato, Massimo, Verhasselt, Bruno·2012·PLoS ONE

Abstract

Quantification of retroviruses in cell culture supernatants and other biological preparations is required in a diverse spectrum of laboratories and applications. Methods based on antigen detection, such as p24 for HIV, or on genome detection are virus specific and sometimes suffer from a limited dynamic range of detection. In contrast, measurement of reverse transcriptase (RT) activity is a generic method which can be adapted for higher sensitivity using real-time PCR quantification (qPCR-based product-enhanced RT (PERT) assay). We present an evaluation of a modified SYBR Green I-based PERT assay (SG-PERT), using commercially available reagents such as MS2 RNA and ready-to-use qPCR mixes. This assay has a dynamic range of 7 logs, a sensitivity of 10 nU HIV-1 RT and outperforms p24 ELISA for HIV titer determination by lower inter-run variation, lower cost and higher linear range. The SG-PERT values correlate with transducing and infectious units in HIV-based viral vector and replication-competent HIV-1 preparations respectively. This assay can furthermore quantify Moloney Murine Leukemia Virus-derived vectors and can be performed on different instruments, such as Roche Lightcycler® 480 and Applied Biosystems ABI 7300. We consider this test to be an accurate, fast and relatively cheap method for retroviral quantification that is easily implemented for use in routine and research laboratories.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0050859

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 208

Metadata

Authors
Vermeire, J., Naessens, E., Vanderstraeten, H., Landi, A., Iannucci, V., Van Nuffel, A., Taghon, T., Pizzato, M., & Verhasselt, B.
Venue
PLoS ONE
Published
2012-12-05
Volume
7
Issue
12
Pages
e50859
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2102059779
Cited by
208
References
1
FWCI
2.32
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of Reverse Transcriptase Activity by Real-Time PCR as a Fast and Accurate Method for Titration of HIV, Lenti- and Retroviral Vectors. https://app.cochat.ai/papers/10.1371/journal.pone.0050859
The paper
Vermeire, J., Naessens, E., Vanderstraeten, H., Landi, A., Iannucci, V., Van Nuffel, A., Taghon, T., Pizzato, M., & Verhasselt, B. (2012). Quantification of Reverse Transcriptase Activity by Real-Time PCR as a Fast and Accurate Method for Titration of HIV, Lenti- and Retroviral Vectors. PLoS ONE. https://doi.org/10.1371/journal.pone.0050859

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.