Validation of Dual Energy X-Ray Absorptiometry Measures of Abdominal Fat by Comparison with Magnetic Resonance Imaging in an Indian Population
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Abdominal adiposity is an important risk factor for diabetes and cardiovascular disease in Indians. Dual energy X-ray absorptiometry (DXA) can be used to determine abdominal fat depots, being more accessible and less costly than gold standard measures such as magnetic resonance imaging (MRI). DXA has not been fully validated for use in South Asians. Here, we determined the accuracy of DXA for measurement of abdominal fat in an Indian population by comparison with MRI. DESIGN: 146 males and females (age range 18-74, BMI range 15-46 kg/m(2)) from Hyderabad, India underwent whole body DXA scans on a Hologic Discovery A scanner, from which fat mass in two abdominal regions was calculated, from the L1 to L4 vertebrae (L1L4) and from the L2 to L4 vertebrae (L2L4). Abdominal MRI scans (axial T1-weighted spin echo images) were taken, from which adipose tissue volumes were calculated for the same regions. RESULTS: Intra-class correlation coefficients between DXA and MRI measures of abdominal fat were high (0.98 for both regions). Although at the level of the individual, differences between DXA and MRI could be large (95% of DXA measures were between 0.8 and 1.4 times MRI measures), at the sample level, DXA only slightly overestimated MRI measures of abdominal fat mass (mean difference in L1L4 region: 2% (95% CI:0%, 5%), mean difference in L2L4 region:4% (95% CI: 1%, 7%)). There was evidence of a proportional bias in the association between DXA and MRI (correlation between difference and mean -0.3), with overestimation by DXA greater in individuals with less abdominal fat (mean bias in leaner half of sample was 6% for L1L4 (95%CI: 2, 11%) and 7% for L2L4 (95% CI:3,12%). CONCLUSIONS: DXA measures of abdominal fat are suitable for use in Indian populations and provide a good indication of abdominal adiposity at the population level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Percent body fat via DEXA: comparison with a four-compartment model
van der Ploeg, G. E., Withers, R. T., & Laforgia, J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00436.2002 · Cited by 163 · cited 1×
“Bias by subject size is a common feature of method comparison studies of DXA measures of body fat [25;30–33] and has been shown to act in the opposite direction (DXA underestimating fat in leaner individuals and overestimating in fatter individuals) in several studies [30–32].”
Method
Cited by
Hangartner, T. N., Warner, S., Braillon, P., Jankowski, L., & Shepherd, J. (2013) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2013.08.007 · Cited by 242
“As previously noted, several studies have been performed to compare DXA results with those of CT (37,63) or MRI (66).”
ResultMeasuring Muscle Mass and Strength in Obesity: a Review of Various Methods
Sizoo, D., de Heide, L. J. M., Emous, M., van Zutphen, T., Navis, G., & van Beek, A. P. (2021) · Obesity Surgery · doi:10.1007/s11695-020-05082-2 · Cited by 77
“However, these studies excluded individuals who did not fit within the DXA field-of-view or exceeded the CT radial size [50].”
BackgroundMouchti, S., Orliacq, J., Reeves, G., & Chen, Z. (2023) · BMC Medical Imaging · doi:10.1186/s12880-023-01063-w · Cited by 38
Grove, J., & Hung, Y.-J. (2017) · Journal of Physical Therapy and Sports Medicine · doi:10.35841/physical-therapy.1.1.5-11 · Cited by 6
“Results from DXA also have a strong correlation to the data examined with magnetic resonance imaging, computed tomography, and multi-compartmental models [23-26,22].”
Metadata
- Authors
- Taylor, A. E., Kuper, H., Varma, R. D., Wells, J. C., Bell, J. D., V.Radhakrishna, K., Kulkarni, B., Kinra, S., Timpson, N. J., Ebrahim, S., Smith, G. D., & Ben-Shlomo, Y.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2012-12-14
- Volume
- 7
- Issue
- 12
- Pages
- e51042
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2143541430
- Cited by
- 42
- References
- 2
- FWCI
- 2.26
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of Dual Energy X-Ray Absorptiometry Measures of Abdominal Fat by Comparison with Magnetic Resonance Imaging in an Indian Population. https://app.cochat.ai/papers/10.1371/journal.pone.0051042
- The paper
- Taylor, A. E., Kuper, H., Varma, R. D., Wells, J. C., Bell, J. D., V.Radhakrishna, K., Kulkarni, B., Kinra, S., Timpson, N. J., Ebrahim, S., Smith, G. D., & Ben-Shlomo, Y. (2012). Validation of Dual Energy X-Ray Absorptiometry Measures of Abdominal Fat by Comparison with Magnetic Resonance Imaging in an Indian Population. PLoS ONE. https://doi.org/10.1371/journal.pone.0051042
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.