Genetic Characteristics of the Human Hepatic Stellate Cell Line LX-2
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The human hepatic cell line LX-2 has been described as tool to study mechanisms of hepatic fibrogenesis and the testing of antifibrotic compounds. It was originally generated by immortalisation with the Simian Vacuolating Virus 40 (SV40) transforming (T) antigen and subsequent propagation in low serum conditions. Although this immortalized line is used in an increasing number of studies, detailed genetic characterisation has been lacking. We here have performed genetic characterisation of the LX-2 cell line and established a single-locus short tandem repeat (STR) profile for the cell line and characterized the LX-2 karyotype by several cytogenetic and molecular cytogenetic techniques. Spectral karyotyping (SKY) revealed a complex karyotype with a set of aberrations consistently present in the metaphases analyses which might serve as cytogenetic markers. In addition, various subclonal and single cell aberrations were detected. Our study provides criteria for genetic authentication of LX-2 and offers insights into the genotype changes which might underlie part of its phenotypic features.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hepatic Stellate Cells: Protean, Multifunctional, and Enigmatic Cells of the Liver
Friedman, S. L. (2008) · Physiological Reviews · doi:10.1152/physrev.00013.2007 · Cited by 2,842 · cited 1×
“During liver fibrogenesis and the establishment of cirrhosis, contractile myofibroblasts (MFB) that originate from quiescent hepatic stellate cells (HSC) are the major source of extracellular matrix (ECM) [1].”
Self-citationHistory, Heterogeneity, Developmental Biology, and Functions of Quiescent Hepatic Stellate Cells
Geerts, A. (2001) · Seminars in Liver Disease · doi:10.1055/s-2001-17550 · Cited by 740
Short tandem repeat profiling provides an international reference standard for human cell lines
Masters, J. R., Thomson, J. A., Daly-Burns, B., Reid, Y. A., Dirks, W. G., Packer, P., Toji, L. H., Ohno, T., Tanabe, H., Arlett, C. F., et al. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.121616198 · Cited by 478 · cited 2×
“This approach provides a simple method for rapid and cheap cell line identification [35] and further enables the establishment of a public STR profile database under the auspices of the National Center for Biotechnology information [30].”
Cell line misidentification: the beginning of the end
American Type Culture Collection Standards Development Organization Workgroup ASN-0002 (2010) · Nature Reviews Cancer · doi:10.1038/nrc2852 · Cited by 266
He, H., Mennone, A., Boyer, J. L., & Cai, S.-Y. (2011) · Hepatology · doi:10.1002/hep.24047 · Cited by 119 · cited 1×
“Since the first report in 2003 [6] and the more detailed characterisation two years later [4], LX-2 cells have been cited nowadays in 158 peer reviewed publications (Figure S1) not only in the field of gastroenterology and hepatology [7–9] but also in studies focused on cellular and molecular biology [10], pharmacolog…”
Barallon, R., Bauer, S. R., Butler, J., Capes-Davis, A., Dirks, W. G., Elmore, E., Furtado, M., Kline, M. C., Kohara, A., Los, G. V., et al. (2010) · In Vitro Cellular & Developmental Biology - Animal · doi:10.1007/s11626-010-9333-z · Cited by 116 · cited 1×
“This approach provides a simple method for rapid and cheap cell line identification [35] and further enables the establishment of a public STR profile database under the auspices of the National Center for Biotechnology information [30].”
Cited by
Rho, H., Terry, A. R., Chronis, C., & Hay, N. (2023) · Cell Metabolism · doi:10.1016/j.cmet.2023.06.013 · Cited by 404
Experimental models of liver fibrosis
Crespo Yanguas, S., Cogliati, B., Willebrords, J., Maes, M., Colle, I., van den Bossche, B., de Oliveira, C. P. M. S., Andraus, W., Alves, V. A., Leclercq, I., et al. (2016) · Archives of Toxicology · doi:10.1007/s00204-015-1543-4 · Cited by 350
A microfluidically perfused three dimensional human liver model
Rennert, K., Steinborn, S., Gröger, M., Ungerböck, B., Jank, A.-M., Ehgartner, J., Nietzsche, S., Dinger, J., Kiehntopf, M., Funke, H., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.08.043 · Cited by 255
In Vitro Models for Non-Alcoholic Fatty Liver Disease: Emerging Platforms and Their Applications
Ramos, M. J., Bandiera, L., Menolascina, F., & Fallowfield, J. A. (2022) · iScience · doi:10.1016/j.isci.2021.103549 · Cited by 127
Hepatic stellate cells control liver zonation, size and functions via R-spondin 3
Sugimoto, A., Saito, Y., Wang, G., Sun, Q., Yin, C., Lee, K. H., Geng, Y., Rajbhandari, P., Hernandez, C., Steffani, M., et al. (2025) · Nature · doi:10.1038/s41586-025-08677-w · Cited by 133
Metadata
- Authors
- Weiskirchen, R., Weimer, J., Meurer, S. K., Kron, A., Seipel, B., Vater, I., Arnold, N., Siebert, R., Xu, L., Friedman, S. L., & Bergmann, C.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-10-08
- Volume
- 8
- Issue
- 10
- Pages
- e75692
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2071603528
- Cited by
- 76
- References
- 6
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.