CoChat

Implementation of Microfluidic Sandwich ELISA for Superior Detection of Plant Pathogens

Open access

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

Abstract

Rapid and economical screening of plant pathogens is a high-priority need in the seed industry. Crop quality control and disease surveillance demand early and accurate detection in addition to robustness, scalability, and cost efficiency typically required for selective breeding and certification programs. Compared to conventional bench-top detection techniques routinely employed, a microfluidic-based approach offers unique benefits to address these needs simultaneously. To our knowledge, this work reports the first attempt to perform microfluidic sandwich ELISA for Acidovorax citrulli (Ac), watermelon silver mottle virus (WSMoV), and melon yellow spot virus (MYSV) screening. The immunoassay occurs on the surface of a reaction chamber represented by a microfluidic channel. The capillary force within the microchannel draws a reagent into the reaction chamber as well as facilitates assay incubation. Because the underlying pad automatically absorbs excess fluid, the only operation required is sequential loading of buffers/reagents. Buffer selection, antibody concentrations, and sample loading scheme were optimized for each pathogen. Assay optimization reveals that the 20-folds lower sample volume demanded by the microchannel structure outweighs the 2- to 4-folds higher antibody concentrations required, resulting in overall 5-10 folds of reagent savings. In addition to cutting the assay time by more than 50%, the new platform offers 65% cost savings from less reagent consumption and labor cost. Our study also shows 12.5-, 2-, and 4-fold improvement in assay sensitivity for Ac, WSMoV, and MYSV, respectively. Practical feasibility is demonstrated using 19 real plant samples. Given a standard 96-well plate format, the developed assay is compatible with commercial fluorescent plate readers and readily amendable to robotic liquid handling systems for completely hand-free assay automation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0083231

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Schematic workflow depicting sequential molecular binding events of the sandwich ELISA. Within each reaction chamber, the capture antibody is adsorbed on the reactive surface followed by surface passivation by a blocking buffer. Upon target binding to the capture antibody, alkaline phosphates (AP)-tagged detection antibody specific to the antigen is added. Addition of fluorescent substrate (PNPP or p-nitrophenyl phosphate for the traditional well format, and Attophos for the micofluidic format) activated by AP generates detectable fluorescent signal, indicating successful binding events.
Figure 1 Schematic workflow depicting sequential molecular binding events of the sandwich ELISA. Within each reaction chamber, the capture antibody is adsorbed on the reactive surface followed by surface passivation by a blocking buffer. Upon target binding to the capture antibody, alkaline phosphates (AP)-tagged detection antibody specific to the antigen is added. Addition of fluorescent substrate (PNPP or p-nitrophenyl phosphate for the traditional well format, and Attophos for the micofluidic format) activated by AP generates detectable fluorescent signal, indicating successful binding events.CC BY · PubMed Central
Figure 2 Coating and blocking buffer selection. A. Different coating buffers (Optibind A-L) were tested for maximum surface binding of 11E5, 2D6, and 5E7 (n = 3). B. Blocking buffers (2% BSA, 3% skim milk, 1% casein, and Optiblock solution) were tested for Ac, WSMoV, and MYSV detection (n = 3). An ideal blocking buffer resulted in highest S/N ratios. Error bars indicate ± standard deviations.
Figure 2 Coating and blocking buffer selection. A. Different coating buffers (Optibind A-L) were tested for maximum surface binding of 11E5, 2D6, and 5E7 (n = 3). B. Blocking buffers (2% BSA, 3% skim milk, 1% casein, and Optiblock solution) were tested for Ac, WSMoV, and MYSV detection (n = 3). An ideal blocking buffer resulted in highest S/N ratios. Error bars indicate ± standard deviations.CC BY · PubMed Central
Figure 3 Optimization of antibody concentration. Nine different conditions for each disease panel were tested on the microfluidic platform using combinations of three concentrations of capture Ab (11E5, 2D6, and 5E7) and three concentrations of detection Ab (MPC-AP, MYSV6-AP). Panel A–C show results for Ac, WSMoV, and MYSV detection, respectively (n = 4). The S/N ratios were plotted for each of the conditions tested. Error bars indicate ± standard deviations.
Figure 3 Optimization of antibody concentration. Nine different conditions for each disease panel were tested on the microfluidic platform using combinations of three concentrations of capture Ab (11E5, 2D6, and 5E7) and three concentrations of detection Ab (MPC-AP, MYSV6-AP). Panel A–C show results for Ac, WSMoV, and MYSV detection, respectively (n = 4). The S/N ratios were plotted for each of the conditions tested. Error bars indicate ± standard deviations.CC BY · PubMed Central
Figure 4 Specificity determination. Specificity of the 11E5/MPC, 2D6/MYSV6, and 5E7/MYSV6 antibody pairs was tested for Ac, WSMoV, and MYSV, respectively. The antibody pairs were tested against bacteria (Ac, SQB, Pf, and DAc) and viral (TYLCV) protein standards (n = 3). The data shows averaged S/N values with error bars representing standard deviations. The dotted horizontal line indicates the threshold (or the cutoff value) of S/N = 2 (twice of values obtained from negative controls).
Figure 4 Specificity determination. Specificity of the 11E5/MPC, 2D6/MYSV6, and 5E7/MYSV6 antibody pairs was tested for Ac, WSMoV, and MYSV, respectively. The antibody pairs were tested against bacteria (Ac, SQB, Pf, and DAc) and viral (TYLCV) protein standards (n = 3). The data shows averaged S/N values with error bars representing standard deviations. The dotted horizontal line indicates the threshold (or the cutoff value) of S/N = 2 (twice of values obtained from negative controls).CC BY · PubMed Central
Figure 5 Study of repetitive sample loading. Effect of repetitive sample loading on assay dynamic range was investigated, using Ac as a model. The plot indicates that multiple loading helps increase assay sensitivity (n = 3). Error bars indicate ± standard deviations.
Figure 5 Study of repetitive sample loading. Effect of repetitive sample loading on assay dynamic range was investigated, using Ac as a model. The plot indicates that multiple loading helps increase assay sensitivity (n = 3). Error bars indicate ± standard deviations.CC BY · PubMed Central
Figure 6 Sensitivity determination of the microfluidic platform. Comparison of assay dynamic range for Ac (A), WSMoV (B), and MYSV (C) detection between protein standards and spiked plant extracts (n = 3) by the microfluidic platform. Error bars indicate ± standard deviations.
Figure 6 Sensitivity determination of the microfluidic platform. Comparison of assay dynamic range for Ac (A), WSMoV (B), and MYSV (C) detection between protein standards and spiked plant extracts (n = 3) by the microfluidic platform. Error bars indicate ± standard deviations.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 35 references

Cited by

See all 34

Metadata

Authors
Thaitrong, N., Charlermroj, R., Himananto, O., Seepiban, C., & Karoonuthaisiri, N.
Affiliations
National Science and Technology Development Agency (TH)
Corresponding author
Thaitrong, Numrin
Venue
PLoS ONE
Published
2013-12-23
Volume
8
Issue
12
Pages
e83231
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2015115692
Cited by
34
References
35
Citations by year
2026: 1 · 2025: 5 · 2024: 2 · 2023: 4 · 2022: 1 · 2020: 1 · 2019: 3 · 2018: 4 · 2017: 3 · 2016: 4 · 2015: 2 · 2014: 3
FWCI
1.66
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Figshare (submittedVersion, cc-by)
  • Greater South Information System
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Life Sciences › Agricultural and Biological Sciences › Plant Science › Plant Virus Research Studies
Keywords
plant pathogen detection, Acidovorax citrulli, Watermelon silver mottle virus, seed certification, reagent cost reduction, assay sensitivity, robotic liquid handling
MeSH terms
Animals, Antibodies, Bacterial, Antibodies, Viral, Enzyme-Linked Immunosorbent Assay, Plant Diseases, Plants, Rabbits, Robotics, Sensitivity and Specificity, Time Factors, Tospovirus, Comamonadaceae, Microfluidic Analytical Techniques, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.