Non-Invasive Assessment of Hepatic Steatosis in Patients with NAFLD Using Controlled Attenuation Parameter and 1H-MR Spectroscopy

Open access
Karlas, Thomas, Petroff, David, Garnov, Nikita, Böhm, Stephan, Tenckhoff, Hannelore, Wittekind, Christian, Wiese, Manfred, Schiefke, Ingolf, Linder, Nicolas, Schaudinn, Alexander, Busse, Harald, Kahn, Thomas, Mössner, Joachim, Berg, Thomas, Tröltzsch, Michael, Keim, Volker, Wiegand, Johannes·2014·PLoS ONE

Abstract

INTRODUCTION: Non-invasive assessment of steatosis and fibrosis is of growing relevance in non-alcoholic fatty liver disease (NAFLD). 1H-Magnetic resonance spectroscopy (1H-MRS) and the ultrasound-based controlled attenuation parameter (CAP) correlate with biopsy proven steatosis, but have not been correlated with each other so far. We therefore performed a head-to-head comparison between both methods. METHODS: Fifty patients with biopsy-proven NAFLD and 15 healthy volunteers were evaluated with 1H-MRS and transient elastography (TE) including CAP. Steatosis was defined according to the percentage of affected hepatocytes: S1 5-33%, S2 34-66%, S3 ≥67%. RESULTS: Steatosis grade in patients with NAFLD was S1 36%, S2 40% and S3 24%. CAP and 1H-MRS significantly correlated with histopathology and showed comparable accuracy for the detection of hepatic steatosis: areas under the receiver-operating characteristics curves were 0.93 vs. 0.88 for steatosis ≥S1 and 0.94 vs. 0.88 for ≥S2, respectively. Boot-strapping analysis revealed a CAP cut-off of 300 dB/m for detection of S2-3 steatosis, while retaining the lower cut-off of 215 dB/m for the definition of healthy individuals. Direct comparison between CAP and 1H-MRS revealed only modest correlation (total cohort: r = 0.63 [0.44, 0.76]; NAFLD cases: r = 0.56 [0.32, 0.74]). For detection of F2-4 fibrosis TE had sensitivity and specificity of 100% and 98.1% at a cut-off value of 8.85 kPa. CONCLUSION: Our data suggest a comparable diagnostic value of CAP and 1H-MRS for hepatic steatosis quantification. Combined with the simultaneous TE fibrosis assessment, CAP represents an efficient method for non-invasive characterization of NAFLD. Limited correlation between CAP and 1H-MRS may be explained by different technical aspects, anthropometry, and presence of advanced liver fibrosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0091987

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 168

Metadata

Authors
Karlas, T., Petroff, D., Garnov, N., Böhm, S., Tenckhoff, H., Wittekind, C., Wiese, M., Schiefke, I., Linder, N., Schaudinn, A., Busse, H., Kahn, T., Mössner, J., Berg, T., Tröltzsch, M., Keim, V., & Wiegand, J.
Venue
PLoS ONE
Published
2014-03-17
Volume
9
Issue
3
Pages
e91987
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2002719027
Cited by
168
References
8
FWCI
10.56
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non-Invasive Assessment of Hepatic Steatosis in Patients with NAFLD Using Controlled Attenuation Parameter and 1H-MR Spectroscopy. https://app.cochat.ai/papers/10.1371/journal.pone.0091987
The paper
Karlas, T., Petroff, D., Garnov, N., Böhm, S., Tenckhoff, H., Wittekind, C., Wiese, M., Schiefke, I., Linder, N., Schaudinn, A., Busse, H., Kahn, T., Mössner, J., Berg, T., Tröltzsch, M., Keim, V., & Wiegand, J. (2014). Non-Invasive Assessment of Hepatic Steatosis in Patients with NAFLD Using Controlled Attenuation Parameter and 1H-MR Spectroscopy. PLoS ONE. https://doi.org/10.1371/journal.pone.0091987

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.