A Method to Assess Adherence in Inhaler Use through Analysis of Acoustic Recordings of Inhaler Events

Open access
D'Arcy, Shona, MacHale, Elaine, Seheult, Jansen, Holmes, Martin S., Hughes, Cian, Sulaiman, Imran, Hyland, Deirdre, O'Reilly, Conor, Glynn, Senan, Al-Zaabi, Thekra, McCourt, John, Taylor, Terence, Keane, Frank, Killane, Isabelle, Reilly, Richard B., Costello, Richard W. · 2014 · PLoS ONE
Cited by 80

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

RATIONALE: Poor adherence to inhaler use can be due to poor temporal and/or technique adherence. Up until now there has been no way of reliably tracking both these factors in everyday inhaler use. OBJECTIVES: This paper introduces a device developed to create time stamped acoustic recordings of an individual's inhaler use, in which empirical evidence of temporal and technique adherence in inhaler use can be monitored over time. The correlation between clinical outcomes and adherence, as determined by this device, was compared for temporal adherence alone and combined temporal and technique adherence. FINDINGS: The technology was validated by showing that the doses taken matched the number of audio recordings (r2 = 0.94, p<0.01). To demonstrate that audio analysis of inhaler use gives objective information, in vitro studies were performed. These showed that acoustic profiles of inhalations correlated with the peak inspiratory flow rate (r2 = 0.97, p<0.01), and that the acoustic energy of exhalations into the inhaler was related to the amount of drug removed. Despite training, 16% of participants exhaled into the mouthpiece after priming, in >20% of their inhaler events. Repeated training reduced this to 7% of participants (p = 0.03). When time of use was considered, there was no evidence of a relationship between adherence and changes in AQLQ (r2 = 0.2) or PEFR (r2 = 0.2). Combining time and technique the rate of adherence was related to changes in AQLQ (r2 = 0.53, p = 0.01) and PEFR (r2 = 0.29, p = 0.01). CONCLUSIONS: This study presents a novel method to objectively assess how errors in both time and technique of inhaler use impact on clinical outcomes. TRIAL REGISTRATION: EudraCT 2011-004149-42.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0098701

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 80

Metadata

Authors
D'Arcy, S., MacHale, E., Seheult, J., Holmes, M. S., Hughes, C., Sulaiman, I., Hyland, D., O'Reilly, C., Glynn, S., Al-Zaabi, T., McCourt, J., Taylor, T., Keane, F., Killane, I., Reilly, R. B., & Costello, R. W.
Venue
PLoS ONE
Published
2014-06-06
Volume
9
Issue
6
Pages
e98701
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2122549120
Cited by
80
References
2
FWCI
6.30
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.