CoChat

Defining Disease Phenotypes Using National Linked Electronic Health Records: A Case Study of Atrial Fibrillation

Open access
Morley, Katherine I., Wallace, Joshua, Denaxas, Spiros C., Hunter, Ross J., Patel, Riyaz S., Perel, Pablo, Shah, Anoop D., Timmis, Adam D., Schilling, Richard J., Hemingway, Harry · 2014 · PLoS ONE
Cited by 96

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

BACKGROUND: National electronic health records (EHR) are increasingly used for research but identifying disease cases is challenging due to differences in information captured between sources (e.g. primary and secondary care). Our objective was to provide a transparent, reproducible model for integrating these data using atrial fibrillation (AF), a chronic condition diagnosed and managed in multiple ways in different healthcare settings, as a case study. METHODS: Potentially relevant codes for AF screening, diagnosis, and management were identified in four coding systems: Read (primary care diagnoses and procedures), British National Formulary (BNF; primary care prescriptions), ICD-10 (secondary care diagnoses) and OPCS-4 (secondary care procedures). From these we developed a phenotype algorithm via expert review and analysis of linked EHR data from 1998 to 2010 for a cohort of 2.14 million UK patients aged ≥ 30 years. The cohort was also used to evaluate the phenotype by examining associations between incident AF and known risk factors. RESULTS: The phenotype algorithm incorporated 286 codes: 201 Read, 63 BNF, 18 ICD-10, and four OPCS-4. Incident AF diagnoses were recorded for 72,793 patients, but only 39.6% (N = 28,795) were recorded in primary care and secondary care. An additional 7,468 potential cases were inferred from data on treatment and pre-existing conditions. The proportion of cases identified from each source differed by diagnosis age; inferred diagnoses contributed a greater proportion of younger cases (≤ 60 years), while older patients (≥ 80 years) were mainly diagnosed in SC. Associations of risk factors (hypertension, myocardial infarction, heart failure) with incident AF defined using different EHR sources were comparable in magnitude to those from traditional consented cohorts. CONCLUSIONS: A single EHR source is not sufficient to identify all patients, nor will it provide a representative sample. Combining multiple data sources and integrating information on treatment and comorbid conditions can substantially improve case identification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0110900

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 96

Metadata

Authors
Morley, K. I., Wallace, J., Denaxas, S. C., Hunter, R. J., Patel, R. S., Perel, P., Shah, A. D., Timmis, A. D., Schilling, R. J., & Hemingway, H.
Venue
PLoS ONE
Published
2014-11-04
Volume
9
Issue
11
Pages
e110900
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2133959708
Cited by
96
References
12
FWCI
4.42
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.