Multichannel Compressive Sensing MRI Using Noiselet Encoding
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
The incoherence between measurement and sparsifying transform matrices and the restricted isometry property (RIP) of measurement matrix are two of the key factors in determining the performance of compressive sensing (CS). In CS-MRI, the randomly under-sampled Fourier matrix is used as the measurement matrix and the wavelet transform is usually used as sparsifying transform matrix. However, the incoherence between the randomly under-sampled Fourier matrix and the wavelet matrix is not optimal, which can deteriorate the performance of CS-MRI. Using the mathematical result that noiselets are maximally incoherent with wavelets, this paper introduces the noiselet unitary bases as the measurement matrix to improve the incoherence and RIP in CS-MRI. Based on an empirical RIP analysis that compares the multichannel noiselet and multichannel Fourier measurement matrices in CS-MRI, we propose a multichannel compressive sensing (MCS) framework to take the advantage of multichannel data acquisition used in MRI scanners. Simulations are presented in the MCS framework to compare the performance of noiselet encoding reconstructions and Fourier encoding reconstructions at different acceleration factors. The comparisons indicate that multichannel noiselet measurement matrix has better RIP than that of its Fourier counterpart, and that noiselet encoded MCS-MRI outperforms Fourier encoded MCS-MRI in preserving image resolution and can achieve higher acceleration factors. To demonstrate the feasibility of the proposed noiselet encoding scheme, a pulse sequences with tailored spatially selective RF excitation pulses was designed and implemented on a 3T scanner to acquire the data in the noiselet domain from a phantom and a human brain. The results indicate that noislet encoding preserves image resolution better than Fouirer encoding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,591
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639 · cited 3×
“where Fsub(K) is them × K submatrix formed from K distinct columns of F, and σmin[Fsub(K)] and σmax[Fsub(K)] are the minimum and maximum singular values of Fsub(K), respectively (In [2, 38, 39], the eigenvalue λ[Fsub(K) Fsub(K)] is used for (5), where λ[Fsub(K) Fsub(K)] = σ(2)[Fsub(K)]).”
BackgroundMethodDecoding by Linear Programming
Candes, E. J., & Tao, T. (2005) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.858979 · Cited by 7,121
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952 · cited 3×
“For solving the minimization program in (10), we used the nonlinear conjugate gradient with the backtracking line search method [7].”
MethodInfluentialNear-Optimal Signal Recovery From Random Projections: Universal Encoding Strategies?
Candes, E. J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.885507 · Cited by 6,839 · cited 2×
“Since (5) must hold for all them × K submatrices of F, the statistics of σmin[Fsub(K)] and σmax[Fsub(K)] over randomly sampled Fsub(K)s are used in [5, 38, 39] to assess the RIP performance of a given measurement matrix F.”
BackgroundMethodSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 1×
“Therefore in the case of regular under-sampling in the noiselet domain, unaliasing with SENSE [8] alone can also be used for noiselet encoding.”
MethodGeneralized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
The restricted isometry property and its implications for compressed sensing
Candès, E. J. (2008) · Comptes Rendus. Mathématique · doi:10.1016/j.crma.2008.03.014 · Cited by 3,686 · cited 1×
“An important sufficient condition for exact reconstruction of x is the so called restricted isometry property (RIP) [2, 21, 23].”
BackgroundComputer vision and pattern recognition
Zheng, N., Loizou, G., Jiang, X., Lan, X., & Li, X. (2007) · International Journal of Computer Mathematics · doi:10.1080/00207160701303912 · Cited by 2,463
Cited by
Yang, G., Yu, S., Dong, H., Slabaugh, G., Dragotti, P. L., Ye, X., Liu, F., Arridge, S., Keegan, J., Guo, Y., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2785879 · Cited by 1,081
Applications of machine learning in animal behaviour studies
Valletta, J. J., Torney, C., Kings, M., Thornton, A., & Madden, J. (2017) · Animal Behaviour · doi:10.1016/j.anbehav.2016.12.005 · Cited by 505
Environmental and health impacts due to e-waste disposal in China – A review
Li, W., & Achal, V. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.139745 · Cited by 318
Magnetic Nanoparticles in Targeted Drug Delivery: a Review
kianfar, E. (2021) · Journal of Superconductivity and Novel Magnetism · doi:10.1007/s10948-021-05932-9 · Cited by 280
Ong, D. C., Kan, C.-C., Pingul-Ong, S. M. B., & de Luna, M. D. G. (2017) · Journal of Environmental Chemical Engineering · doi:10.1016/j.jece.2017.10.046 · Cited by 48
Metadata
- Authors
- Pawar, K., Egan, G., & Zhang, J.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-05-12
- Volume
- 10
- Issue
- 5
- Pages
- e0126386
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2114504143
- Cited by
- 212
- References
- 33
- FWCI
- 29.86
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.