The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Accuracy and Reliability of the Kinect Version 2 for Clinical Measurement of Motor Function
Open accessAbstract
BACKGROUND: The introduction of low cost optical 3D motion tracking sensors provides new options for effective quantification of motor dysfunction. OBJECTIVE: The present study aimed to evaluate the Kinect V2 sensor against a gold standard motion capture system with respect to accuracy of tracked landmark movements and accuracy and repeatability of derived clinical parameters. METHODS: Nineteen healthy subjects were concurrently recorded with a Kinect V2 sensor and an optical motion tracking system (Vicon). Six different movement tasks were recorded with 3D full-body kinematics from both systems. Tasks included walking in different conditions, balance and adaptive postural control. After temporal and spatial alignment, agreement of movements signals was described by Pearson's correlation coefficient and signal to noise ratios per dimension. From these movement signals, 45 clinical parameters were calculated, including ranges of motions, torso sway, movement velocities and cadence. Accuracy of parameters was described as absolute agreement, consistency agreement and limits of agreement. Intra-session reliability of 3 to 5 measurement repetitions was described as repeatability coefficient and standard error of measurement for each system. RESULTS: Accuracy of Kinect V2 landmark movements was moderate to excellent and depended on movement dimension, landmark location and performed task. Signal to noise ratio provided information about Kinect V2 landmark stability and indicated larger noise behaviour in feet and ankles. Most of the derived clinical parameters showed good to excellent absolute agreement (30 parameters showed ICC(3,1) > 0.7) and consistency (38 parameters showed r > 0.7) between both systems. CONCLUSION: Given that this system is low-cost, portable and does not require any sensors to be attached to the body, it could provide numerous advantages when compared to established marker- or wearable sensor based system. The Kinect V2 has the potential to be used as a reliable and valid clinical measurement tool.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foundations of Clinical Research: Applications to Practice,
(2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00362-4 · Cited by 9,489
Lee, K. B., & Eldson, J. (2004) · Cited by 1,074
Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis
Pfister, A., West, A. M., Bronner, S., & Noah, J. A. (2014) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2014.909540 · Cited by 552
Accuracy of the Microsoft Kinect sensor for measuring movement in people with Parkinson's disease
Galna, B., Barry, G., Jackson, D., Mhiripiri, D., Olivier, P., & Rochester, L. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.01.008 · Cited by 544
ISway: a sensitive, valid and reliable measure of postural control
Mancini, M., Salarian, A., Carlson-Kuhta, P., Zampieri, C., King, L., Chiari, L., & Horak, F. B. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-59 · Cited by 499 · cited 1×
“Thus, as observed in other studies [24], repeatability measures may even prove better in patient groups with more diverse motor performance.”
ResultPrinciples of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
WELK, G. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185660.38335.de · Cited by 339
Spain, R. I., St. George, R. J., Salarian, A., Mancini, M., Wagner, J. M., Horak, F. B., & Bourdette, D. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.11.026 · Cited by 287
Evaluation of Pose Tracking Accuracy in the First and Second Generations of Microsoft Kinect
Wang, Q., Kurillo, G., Ofli, F., & Bajcsy, R. (2015) · IEEE International Conference on Healthcare Informatics (ICHI) · doi:10.1109/ichi.2015.54 · Cited by 199
Mentiplay, B. F., Perraton, L. G., Bower, K. J., Pua, Y.-H., McGaw, R., Heywood, S., & Clark, R. A. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.05.021 · Cited by 195
Geerse, D. J., Coolen, B. H., & Roerdink, M. (2015) · PLOS ONE · doi:10.1371/journal.pone.0139913 · Cited by 182
Clark, R. A., Pua, Y.-H., Oliveira, C. C., Bower, K. J., Thilarajah, S., McGaw, R., Hasanki, K., & Mentiplay, B. F. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.03.005 · Cited by 176
Schmitz, A., Ye, M., Shapiro, R., Yang, R., & Noehren, B. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.11.031 · Cited by 160
Clinician versus machine: Reliability and responsiveness of motor endpoints in Parkinson's disease
Heldman, D. A., Espay, A. J., LeWitt, P. A., & Giuffrida, J. P. (2014) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2014.02.022 · Cited by 156
Evaluation of the Microsoft Kinect as a clinical assessment tool of body sway
Yeung, L.-F., Cheng, K. C., Fong, C., Lee, W. C. C., & Tong, R. K. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.06.012 · Cited by 143
Digital Signal Processing: A Computer Science Perspective
Stein, J. (2000) · Wiley eBooks · doi:10.1002/047120059x · Cited by 125
Validity and reliability of Kinect skeleton for measuring shoulder joint angles: a feasibility study
Huber, M. E., Seitz, A. L., Leeser, M. E., & Sternad, D. (2015) · Physiotherapy · doi:10.1016/j.physio.2015.02.002 · Cited by 109
Using perceptive computing in multiple sclerosis - the Short Maximum Speed Walk test
Behrens, J. R., Pfueller, C. F., Mansow‐Model, S., Otte, K., Paul, F., & Brandt, A. U. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-89 · Cited by 60
Self-citationAccuracy of KinectOne to quantify kinematics of the upper body
Kuster, R. P., Heinlein, B., Bauer, C. M., & Graf, E. S. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.04.004 · Cited by 48
Validity of visual perceptive computing for static posturography in patients with multiple sclerosis
Behrens, J. R., Mertens, S., Krüger, T., Grobelny, A., Otte, K., Mansow‐Model, S., Gusho, E., Paul, F., Brandt, A. U., & Schmitz‐Hübsch, T. (2016) · Multiple Sclerosis Journal · doi:10.1177/1352458515625807 · Cited by 44
Self-citationElectronics and Communications for Scientists and Engineers
(2020) · Elsevier eBooks · doi:10.1016/c2018-0-00442-9 · Cited by 16
Cited by
Wade, L., Needham, L., McGuigan, P., & Bilzon, J. (2022) · PeerJ · doi:10.7717/peerj.12995 · Cited by 384
Albert, J. A., Owolabi, V., Gebel, A., Brahms, C. M., Granacher, U., & Arnrich, B. (2020) · Sensors · doi:10.3390/s20185104 · Cited by 261
LimbMotion: Decimeter-level Limb Tracking for Wearable-based Human-Computer Interaction
Zhou, H., Gao, Y., Song, X., Liu, W., & Dong, W. (2019) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3369836 · Cited by 27
Metadata
- Authors
- Otte, K., Kayser, B., Mansow-Model, S., Verrel, J., Paul, F., Brandt, A. U., & Schmitz-Hübsch, T.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2016-11-18
- Volume
- 11
- Issue
- 11
- Pages
- e0166532
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2556558971
- Cited by
- 255
- References
- 20
- FWCI
- 77.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.