Monitoring gait in multiple sclerosis with novel wearable motion sensors
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Mobility impairment is common in people with multiple sclerosis (PwMS) and there is a need to assess mobility in remote settings. Here, we apply a novel wireless, skin-mounted, and conformal inertial sensor (BioStampRC, MC10 Inc.) to examine gait characteristics of PwMS under controlled conditions. We determine the accuracy and precision of BioStampRC in measuring gait kinematics by comparing to contemporary research-grade measurement devices. METHODS: A total of 45 PwMS, who presented with diverse walking impairment (Mild MS = 15, Moderate MS = 15, Severe MS = 15), and 15 healthy control subjects participated in the study. Participants completed a series of clinical walking tests. During the tests participants were instrumented with BioStampRC and MTx (Xsens, Inc.) sensors on their shanks, as well as an activity monitor GT3X (Actigraph, Inc.) on their non-dominant hip. Shank angular velocity was simultaneously measured with the inertial sensors. Step number and temporal gait parameters were calculated from the data recorded by each sensor. Visual inspection and the MTx served as the reference standards for computing the step number and temporal parameters, respectively. Accuracy (error) and precision (variance of error) was assessed based on absolute and relative metrics. Temporal parameters were compared across groups using ANOVA. RESULTS: Mean accuracy±precision for the BioStampRC was 2±2 steps error for step number, 6±9ms error for stride time and 6±7ms error for step time (0.6-2.6% relative error). Swing time had the least accuracy±precision (25±19ms error, 5±4% relative error) among the parameters. GT3X had the least accuracy±precision (8±14% relative error) in step number estimate among the devices. Both MTx and BioStampRC detected significantly distinct gait characteristics between PwMS with different disability levels (p<0.01). CONCLUSION: BioStampRC sensors accurately and precisely measure gait parameters in PwMS across diverse walking impairment levels and detected differences in gait characteristics by disability level in PwMS. This technology has the potential to provide granular monitoring of gait both inside and outside the clinic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Timed “Up & Go”: A Test of Basic Functional Mobility for Frail Elderly Persons
Podsiadlo, D., & Richardson, S. (1991) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1991.tb01616.x · Cited by 14,418
Steffen, T. M., Hacker, T. A., & Mollinger, L. (2002) · Physical Therapy · doi:10.1093/ptj/82.2.128 · Cited by 2,070
Gait velocity as a single predictor of adverse events in healthy seniors aged 75 years and older
Montero-Odasso, M., Schapira, M., Soriano, E. R., Varela, M., Kaplan, R., Camera, L. A., & Mayorga, L. M. (2005) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/60.10.1304 · Cited by 746
Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics
Zhang, J.-T., Novak, A. C., Brouwer, B., & Li, Q. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/8/n63 · Cited by 314
Cited by
Validity and repeatability of inertial measurement units for measuring gait parameters
Washabaugh, E. P., Kalyanaraman, T., Adamczyk, P. G., Claflin, E. S., & Krishnan, C. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.04.013 · Cited by 329
The future of sleep health: a data-driven revolution in sleep science and medicine
Perez-Pozuelo, I., Zhai, B., Palotti, J., Mall, R., Aupetit, M., Garcia-Gomez, J. M., Taheri, S., Guan, Y., & Fernandez-Luque, L. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0244-4 · Cited by 311
Gait analysis in neurological populations: Progression in the use of wearables
Celik, Y., Stuart, S., Woo, W. L., & Godfrey, A. (2021) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2020.11.005 · Cited by 167
Boroojerdi, B., Ghaffari, R., Mahadevan, N., Markowitz, M., Melton, K., Morey, B., Otoul, C., Patel, S., Phillips, J., Sen-Gupta, E., et al. (2019) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2018.11.024 · Cited by 43
Self-citationMichaels, R., Barreira, T. V., Robinovitch, S. N., Sosnoff, J. J., & Moon, Y. (2025) · Scientific Reports · doi:10.1038/s41598-025-85934-y · Cited by 9
“The validity of the IMU sensor (BioStampRC, MC10) was examined in a previous gait analysis study 26 , and its accuracy in measuring the hip impact acceleration was internally validated (Supplementary Fig.”
InfluentialSelf-citation
Metadata
- Authors
- Moon, Y., McGinnis, R. S., Seagers, K., Motl, R. W., Sheth, N., Wright, J. A., Ghaffari, R., & Sosnoff, J. J.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-02-08
- Volume
- 12
- Issue
- 2
- Pages
- e0171346
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2586302922
- Cited by
- 134
- References
- 4
- FWCI
- 42.01
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.