Cited by 195COVID-19 diagnosis using AIArtificial Intelligence in Healthcare and EducationRadiomics and Machine Learning in Medical Imaging

Deep learning in chest radiography: Detection of findings and presence of change

Open access
Singh, Ramandeep, Kalra, Mannudeep K., Nitiwarangkul, Chayanin, Patti, John A., Homayounieh, Fatemeh, Padole, Atul, Rao, Pooja, Putha, Preetham +3 more·2018·PLOS ONE

Abstract

BACKGROUND: Deep learning (DL) based solutions have been proposed for interpretation of several imaging modalities including radiography, CT, and MR. For chest radiographs, DL algorithms have found success in the evaluation of abnormalities such as lung nodules, pulmonary tuberculosis, cystic fibrosis, pneumoconiosis, and location of peripherally inserted central catheters. Chest radiography represents the most commonly performed radiological test for a multitude of non-emergent and emergent clinical indications. This study aims to assess accuracy of deep learning (DL) algorithm for detection of abnormalities on routine frontal chest radiographs (CXR), and assessment of stability or change in findings over serial radiographs. METHODS AND FINDINGS: We processed 874 de-identified frontal CXR from 724 adult patients (> 18 years) with DL (Qure AI). Scores and prediction statistics from DL were generated and recorded for the presence of pulmonary opacities, pleural effusions, hilar prominence, and enlarged cardiac silhouette. To establish a standard of reference (SOR), two thoracic radiologists assessed all CXR for these abnormalities. Four other radiologists (test radiologists), unaware of SOR and DL findings, independently assessed the presence of radiographic abnormalities. A total 724 radiographs were assessed for detection of findings. A subset of 150 radiographs with follow up examinations was used to asses change over time. Data were analyzed with receiver operating characteristics analyses and post-hoc power analysis. RESULTS: About 42% (305/ 724) CXR had no findings according to SOR; single and multiple abnormalities were seen in 23% (168/724) and 35% (251/724) of CXR. There was no statistical difference between DL and SOR for all abnormalities (p = 0.2-0.8). The area under the curve (AUC) for DL and test radiologists ranged between 0.837-0.929 and 0.693-0.923, respectively. DL had lowest AUC (0.758) for assessing changes in pulmonary opacities over follow up CXR. Presence of chest wall implanted devices negatively affected the accuracy of DL algorithm for evaluation of pulmonary and hilar abnormalities. CONCLUSIONS: DL algorithm can aid in interpretation of CXR findings and their stability over follow up CXR. However, in its present version, it is unlikely to replace radiologists due to its limited specificity for categorizing specific findings.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0204155

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 23 · Cited by 195

Research works printed but not linked: 19

  1. [2]Forrest JV, Friedman PJ. Radiologic errors in patients with lung cancer. West J Med. 1981; 134: 485– 490. 7257363 PMC1272834
  2. [3]Quekel LGBA, Kessels AGH, Goei R, van Engelshoven JMA. Miss rate of lung cancer on the chest radiograph in clinical practice. Chest. 1999; 115: 720– 724. 10084482
  3. [4]Tudor GR, Finlay D, Taub N. An assessment of inter-observer agreement and accuracy when reporting plain radiographs. Clin Radiol. 1997; 52: 235– 238. 9091261
  4. [5]Melendez J, Sánchez CI, Philipsen RH, Maduskar P, Dawson R, Theron G, et al An automated tuberculosis screening strategy combining X-ray-based computer-aided detection and clinical information. Sci Rep 2016; 6: 252– 65. PMC4850474 27126741
  5. [6]Hoog AH, Meme HK, van Deutekom H, Mithika AM, Olunga C, Onyino F, et al High sensitivity of chest radiograph reading by clinical officers in a tuberculosis prevalence survey. Int J Tuberc Lung Dis 2011; 15(10): 1308– 14. 10.5588/ijtld.11.0004 22283886 · DOI
  6. [7]Pande T, Cohen C, Pai M, Ahmad Khan F. Computer-aided detection of pulmonary tuberculosis on digital chest radiographs: a systematic review. Int J Tuberc Lung Dis 2016; 20(9): 1226– 30. 10.5588/ijtld.15.0926 27510250 · DOI
  7. [8]Maduskar P, Muyoyeta M, Ayles H, Hogeweg L, Peters-Bax L, van Ginneken B. Detection of tuberculosis using digital chest radiography: automated reading vs. interpretation by clinical officers. Int J Tuberc Lung Dis 2013; 17(12): 1613– 20. 10.5588/ijtld.13.0325 24200278 · DOI · Paper page
  8. [9]Jaeger S, Karargyris A, Candemir S, Folio L, Siegelman J, Callaghan F, et al Automatic tuberculosis screening using chest radiographs. IEEE Trans Med Imaging. 2014 2; 33(2): 233– 45. 10.1109/TMI.2013.2284099 24108713 PMC13288257 · DOI
  9. [10]Hwang S, Kim HE, Jeong J, Kim HJ. A novel approach for tuberculosis screening based on deep convolutional neural networks. In: Tourassi GD, Armato SG, eds. Proceedings of SPIE: medical imaging 2016—title. Vol 9785. Bellingham, Wash: International Society for Optics and Photonics, 2016; 97852W.
  10. [12]Lee MZ, Cai W, Song Y, Selvadurai, Feng. Fully automated scoring of chest radiographs in cystic fibrosis. Engineering in Medicine and Biology Society (EMBC), 35th Annual International Conference of the IEEE 2013:3965–8. 24110600
  11. [13]Shwachman H, Kulczycki LL. Long-term study of one hundred five patients with cystic fibrosis. Am J. Dis. Child. 1958; 7: 6– 15. 13544726
  12. [14]Zhu B, Luo W, Li B, Chen B, Yang Q, Xu Y, et al The development and evaluation of a computerized diagnosis scheme for pneumoconiosis on digital chest radiographs. BioMedical Engineering OnLine. 2014; 13: 141 10.1186/1475-925X-13-141 25277489 PMC4271323 · DOI
  13. [15]Yu P, Xu H, Zhu Y, Yang C, Sun X, Zhao J. An automatic computer-aided detection scheme for pneumoconiosis on digital chest radiographs. J Digit Imaging. 2011; 24: 382– 93. 10.1007/s10278-010-9276-7 20174852 PMC3092047 · DOI
  14. [16]Xu H, Tao X, Sundararajan R. Proceedings of the Third International Workshop on Pulmonary Image Analysis: CreateSpace Independent Publishing Platform; 2010. Computer Aided Detection for Pneumoconiosis Screening on Digital Chest Radiographs 2010; 9: 129– 38.
  15. [17]Wang X, Peng Y, Lu L, Lu Z, Bagheri M, Summers RM. ChestX-ray8: Hospital-scale Chest X-ray Database and Benchmarks on Weakly-Supervised Classification and Localization of Common Thorax Diseases. IEEE CVPR 2017.
  16. [18]Huang G, Zhuang Liu, Van der Maaten L, Weinberger KQ. Densely Connected Convolutional Networks. arXiv:1608.06993. · arXiv
  17. [20]Yao L, Poblenz E, Dagunts D, Covington B, Bernard D, Lyman K. Learning to diagnose from scratch by exploiting dependencies among labels. arXiv preprint arXiv:1710.10501, 2017. · arXiv
  18. [21]Rajpurkar P, Irvin J, Zhu K, Yang B, Mehta H, Duan T, et al CheXNet: Radiologist-level pneumonia detection on chest X-rays with deep learning. https://arxiv.org/abs/1711.05225, 2017. · arXiv
  19. [22]Becker AS, Blüthgen C, Phi van VD, Sekaggya-Wiltshire C, Castelnuovo B, Kambugu A, et al Detection of tuberculosis patterns in digital photographs of chest X-ray images using Deep Learning: feasibility study. Int J Tuberc Lung Dis. 2018; 22(3): 328– 35. 10.5588/ijtld.17.0520 29471912 · DOI

Authors
Singh, R., Kalra, M. K., Nitiwarangkul, C., Patti, J. A., Homayounieh, F., Padole, A., Rao, P., Putha, P., Muse, V. V., Sharma, A., & Digumarthy, S. R.
Affiliations
  • Harvard University (US)
  • Qure.ai Technologies Private Limited (India) (IN)
Corresponding author
Digumarthy, Subba R.
Venue
PLOS ONE
Published
2018-10-04
Volume
13
Issue
10
Pages
e0204155
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2895598278
Cited by
195
References
23
Citations by year
2026: 3 · 2025: 18 · 2024: 20 · 2023: 29 · 2022: 39 · 2021: 35 · 2020: 41 · 2019: 9 · 2018: 1
FWCI
14.85
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › COVID-19 diagnosis using AI
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
Keywords
chest radiography, deep learning, pulmonary opacities, pleural effusion, radiologist interpretation, algorithm accuracy, computer-aided detection, radiology workforce shortage, radiology residency
MeSH terms
Deep Learning, Adult, Aged, Algorithms, Female, Humans, Lung, Male, Middle Aged, Radiographic Image Enhancement, Reference Standards, Retrospective Studies, ROC Curve, Radiography, Thoracic, Observer Variation, Area Under Curve

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review