Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; the references it cites are not checked yet.

Repeatability and reproducibility of multiparametric magnetic resonance imaging of the liver

Open access

Abstract

As the burden of liver disease reaches epidemic levels, there is a high unmet medical need to develop robust, accurate and reproducible non-invasive methods to quantify liver tissue characteristics for use in clinical development and ultimately in clinical practice. This prospective cross-sectional study systematically examines the repeatability and reproducibility of iron-corrected T1 (cT1), T2*, and hepatic proton density fat fraction (PDFF) quantification with multiparametric MRI across different field strengths, scanner manufacturers and models. 61 adult participants with mixed liver disease aetiology and those without any history of liver disease underwent multiparametric MRI on combinations of 5 scanner models from two manufacturers (Siemens and Philips) at different field strengths (1.5T and 3T). We report high repeatability and reproducibility across different field strengths, manufacturers, and scanner models in standardized cT1 (repeatability CoV: 1.7%, bias -7.5ms, 95% LoA of -53.6 ms to 38.5 ms; reproducibility CoV 3.3%, bias 6.5 ms, 95% LoA of -76.3 to 89.2 ms) and T2* (repeatability CoV: 5.5%, bias -0.18 ms, 95% LoA -5.41 to 5.05 ms; reproducibility CoV 6.6%, bias -1.7 ms, 95% LoA -6.61 to 3.15 ms) in human measurements. PDFF repeatability (0.8%) and reproducibility (0.75%) coefficients showed high precision of this metric. Similar precision was observed in phantom measurements. Inspection of the ICC model indicated that most of the variance in cT1 could be accounted for by study participants (ICC = 0.91), with minimal contribution from technical differences. We demonstrate that multiparametric MRI is a non-invasive, repeatable and reproducible method for quantifying liver tissue characteristics across manufacturers (Philips and Siemens) and field strengths (1.5T and 3T).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0214921

Cites

Statistics

Figures

Fig 1 Study design. Two manufacturers (Siemens and Philips) and a range of scanner models were used to systematically test the repeatability and reproducibility of multiparametric-MRI derived measurements in human participants and phantoms.
Fig 1 Study design. Two manufacturers (Siemens and Philips) and a range of scanner models were used to systematically test the repeatability and reproducibility of multiparametric-MRI derived measurements in human participants and phantoms.CC BY · PubMed Central
Fig 2 Phantom T1 Standardisation. Bland-Altman plots demonstrating T1 measurements in phantoms before and after standardisation at (a) 1.5T and (b) 3T.
Fig 2 Phantom T1 Standardisation. Bland-Altman plots demonstrating T1 measurements in phantoms before and after standardisation at (a) 1.5T and (b) 3T.CC BY · PubMed Central
Fig 3 Repeatability and reproducibility of phantom measurements. Bland-Altman plots from phantom measurements across manufacturer and field strength for (a) T1, (b) T2*, and (c) PDFF.
Fig 3 Repeatability and reproducibility of phantom measurements. Bland-Altman plots from phantom measurements across manufacturer and field strength for (a) T1, (b) T2*, and (c) PDFF.CC BY · PubMed Central
Fig 4 Repeatability and reproducibility of human multiparametric MRI measurements. Bland-Altman plots from human measurements across manufacturer and field strength for (a) cT1, (b) T2*, and (c) PDFF.
Fig 4 Repeatability and reproducibility of human multiparametric MRI measurements. Bland-Altman plots from human measurements across manufacturer and field strength for (a) cT1, (b) T2*, and (c) PDFF.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists are queued

They are fetched later and appear here then.

References 33 · Cited by 117

Research works printed but not linked: 1

  1. R. C. Team and others, “R foundation for statistical computing,” Vienna, Austria, vol. 3, no. 0, 2013.

Metadata

Authors
Bachtiar, V., Kelly, M. D., Wilman, H. R., Jacobs, J., Newbould, R., Kelly, C. J., Gyngell, M. L., Groves, K. E., McKay, A., Herlihy, A. H., Fernandes, C. C., Halberstadt, M., Maguire, M., Jayaratne, N., Linden, S., Neubauer, S., & Banerjee, R.
Affiliations
  • Perspectum Ltd. (United Kingdom) (GB)
  • University of Oxford (GB)
Corresponding author
Bachtiar, Velicia
Venue
PLOS ONE
Published
2019-04-10
Volume
14
Issue
4
Pages
e0214921
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2939501546
Cited by
117
References
33
Citations by year
2026: 10 · 2025: 20 · 2024: 20 · 2023: 9 · 2022: 19 · 2021: 17 · 2020: 19 · 2019: 2
FWCI
9.40
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • WestminsterResearch (University of Westminster) (acceptedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Figshare (submittedVersion, cc-by)
Funders
National Institute for Health and Care Research
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Hepatology › Liver Disease Diagnosis and Treatment
  • Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
Keywords
multiparametric MRI, liver MRI, repeatability, reproducibility, T2 mapping, proton density fat fraction, liver iron quantification, field strength, liver disease
MeSH terms
Multiparametric Magnetic Resonance Imaging, Adult, Aged, Aged, 80 and over, Cross-Sectional Studies, Female, Humans, Image Interpretation, Computer-Assisted, Liver, Male, Middle Aged, Prospective Studies, Reproducibility of Results, Phantoms, Imaging, Young Adult, Non-alcoholic Fatty Liver Disease

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Repeatability and reproducibility of multiparametric magnetic resonance imaging of the liver. https://app.cochat.ai/papers/10.1371/journal.pone.0214921
The paper
Bachtiar, V., Kelly, M. D., Wilman, H. R., Jacobs, J., Newbould, R., Kelly, C. J., Gyngell, M. L., Groves, K. E., McKay, A., Herlihy, A. H., Fernandes, C. C., Halberstadt, M., Maguire, M., Jayaratne, N., Linden, S., Neubauer, S., & Banerjee, R. (2019). Repeatability and reproducibility of multiparametric magnetic resonance imaging of the liver. PLOS ONE. https://doi.org/10.1371/journal.pone.0214921

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.