Blood Loss from Laboratory Tests
The DOI matches its Crossref record.
Abstract
Background: Laboratory tests can be an important source of blood loss in hospitals, especially for newborns and patients in intensive care. The aim of this study was to quantify blood loss for laboratory diagnostic tests in a large number of patients in a teaching hospital. Methods: We estimated blood loss by multiplying the number and volumes of sampling tubes collected from 2654 adult inpatients. We compared the number of tests per patient for all inpatients and intensive care unit patients during the first period and again in the same time period 1 year later when cumulative blood-loss volumes were being reported to physicians and educational information had been given to decrease blood loss from laboratory tests. Results: For 95% of the patients, blood loss during hospitalization was <196 mL. The largest proportion of the blood samples was used for clinical chemical tests (median, 45%), followed by hematologic (median, 26%) and coagulation (median, 17%) tests. In the surgical and cardiovascular surgical intensive care units, however, blood gas analyses accounted for 19–34% (medians) of the use. For 5% of the patients, all undergoing intensive care, blood loss was >200 mL and for 0.7% was >600 mL during their hospital stay. Such high blood losses were observed in patients with long-term ventilation, coagulation disorders, and repeated surgery. The largest median blood loss was in patients undergoing cardiovascular surgery (median, 201 mL). The mean number of tests was 44 per inpatient before cumulative blood loss was being reported and 46 when it was being reported. Conclusions: Blood loss from laboratory diagnostic testing is not likely to pose a problem for most hospitalized patients. Blood loss is greater in intensive care patients and after cardiovascular surgical procedures. Reporting of the cumulative individual blood loss did not decrease blood loss for laboratory testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Effect of Perioperative Anemia on Clinical and Functional Outcomes in Patients With Hip Fracture
Halm, E. A., Wang, J. J., Boockvar, K., Penrod, J., Silberzweig, S. B., Magaziner, J., Koval, K. J., & Siu, A. L. (2004) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200407000-00007 · Cited by 276
Thavendiranathan, P., Bagai, A., Ebidia, A., Detsky, A. S., & Choudhry, N. K. (2005) · Journal of General Internal Medicine · doi:10.1111/j.1525-1497.2005.0094.x · Cited by 260
“H ospitalized patients frequently have considerable volumes of blood drawn (phlebotomy) for diagnostic testing during short periods of time.(1) This may cause hemoglobin and hematocrit levels to fall, as commonly observed during hospitalization.”
BackgroundSalisbury, A. C. (2011) · Archives of Internal Medicine · doi:10.1001/archinternmed.2011.361 · Cited by 194
“Finally, we repeated the analyses using several alternative assumptions for standard adult blood tube volumes and using volumes reported to fill pediatric blood tubes.(9,11,13,21,22) All statistical analyses were evaluated at a 2-sided significance level of P =.”
MethodLippi, G., von Meyer, A., Cadamuro, J., & Simundic, A.-M. (2019) · Diagnosis · doi:10.1515/dx-2018-0018 · Cited by 135
Metadata
- Authors
- Wisser, D., van Ackern, K., Knoll, E., Wisser, H., & Bertsch, T.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-10-01
- Volume
- 49
- Issue
- 10
- Pages
- 1651-1655
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2114694180
- Cited by
- 74
- References
- 0
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.