CoChat

Free Thyroxine Measured by Equilibrium Dialysis and Nine Immunoassays in Sera with Various Serum Thyroxine-binding Capacities

Sapin, Rémy, d’Herbomez, Michèle · 2003 · Clinical Chemistry
Cited by 104

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Despite the predominant role of thyrotropin measurements in the assessment of thyroid status, free thyroxine (FT4) measurements remain useful either when thyrotropin determination is not conclusive or when a diagnosis of thyroid disease must be confirmed (1). Because it represents only a minute fraction (0.02%) of total T4 (TT4), FT4 is more difficult to measure (2). Direct equilibrium dialysis (ED) methods are considered analytically accurate (3) and are the methods against which others are compared (4). Compared with ED, other FT4 immunoassays may show significant biases related to protein-bound T4 or to the serum T4-binding capacity (sBC: concentration × affinity of binding proteins) (4)(5)(6). We assume assays are calibrated to have roughly the same euthyroid range in samples with normal sBC, and we expect that markedly negative biases may be observed in samples with low sBC and that smaller positive biases may be observed in samples with high sBC (7). The aim of our study was to determine, in clinical samples from euthyroid patients classified into three groups as a function of their low, normal, or high sBC, the bias between FT4 measured with ED and that measured with nine frequently used immunoassays. We also studied the specificity of each assay method and the concordance of immunoassays with ED.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/49.9.1531

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 104

Metadata

Authors
Sapin, R., & d’Herbomez, M.
Venue
Clinical Chemistry
Published
2003-09-01
Volume
49
Issue
9
Pages
1531-1535
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2043212062
Cited by
104
References
1
FWCI
0.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.