Simultaneous Determination of Tocotrienols, Tocopherols, Retinol, and Major Carotenoids in Human Plasma
The DOI matches its Crossref record.
Abstract
Background: Epidemiologic evidence suggests that the concentrations of antioxidant vitamins in human plasma may play an important role in numerous chronic diseases, such as cancer and cardiovascular disease. However, methods for simultaneous measurement of these antioxidants are scarce. We developed and validated a new HPLC method for simultaneous determination of these vitamers in human plasma that uses a novel column-switching approach. Methods: The new method uses liquid–liquid extraction and isocratic separation with two monomeric C18 columns maintained at 35 and 4 °C coupled with ultraviolet–visible and fluorometric detection. This method could separate 14 vitamers and 3 internal standards within 27 min. No additional modifier was required; the mobile phase was acetonitrile–methanol (65:35 by volume), and the flow rate was 1 mL/min. Results: For photodiode array detection, the detection limits (signal-to-noise ratio >3) were 0.02 mg/L for β-carotene, lutein, zeaxanthin, and canthaxanthin; 0.01 mg/L for all-trans-retinol, β-cryptoxanthin, α-carotene, and lycopene; and 0.1 mg/L for all tocopherols and tocotrienols. The detection limit was at least 25-fold lower (0.004 mg/L) when fluorometry was used for measurement of δ-, γ-, and α-tocotrienol and δ-tocopherol compared with ultraviolet detection. The recovery and imprecision of the assay were generally >90% and <10%, respectively. Conclusions: This new method separates a wide range of fat-soluble antioxidant vitamins in human plasma, including six carotenoids, three isoforms of tocotrienols and tocopherols (δ-, γ-, and α-), and all-trans-retinol. The overall findings suggest that our method is faster, more sensitive, and more comprehensive than existing methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Antioxidant activity and profiles of common fruits in Singapore
Isabelle, M., Lee, B. L., Lim, M. T., Koh, W.-P., Huang, D., & Ong, C. N. (2010) · Food Chemistry · doi:10.1016/j.foodchem.2010.04.002 · Cited by 268
Self-citationvan de Merbel, N. C. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.09.002 · Cited by 230
Antioxidant activity and profiles of common vegetables in Singapore
Isabelle, M., Lee, B. L., Lim, M. T., Koh, W.-P., Huang, D., & Ong, C. N. (2010) · Food Chemistry · doi:10.1016/j.foodchem.2009.11.038 · Cited by 194
Self-citationA preliminary metabolomic analysis of older adults with and without depression
Paige, L. A., Mitchell, M. W., Krishnan, K. R. R., Kaddurah‐Daouk, R., & Steffens, D. C. (2007) · International Journal of Geriatric Psychiatry · doi:10.1002/gps.1690 · Cited by 136
Laboratory medicine best practice guideline: vitamins a, e and the carotenoids in blood.
(2014) · PubMed Central · Cited by 44
Pek, S. L., Tavintharan, S., Woon, K., Lin, L., Ong, C. N., Lim, S. C., & Sum, C. F. (2016) · Experimental Biology and Medicine · doi:10.1177/1535370215605588 · Cited by 26
Self-citationBoulet, L., Alex, B., Clavey, N., Martinez, J., & Ducros, V. (2020) · Journal of Chromatography B · doi:10.1016/j.jchromb.2020.122158 · Cited by 19
Pan, Q., Shen, M., Yu, T., Yang, X., Li, Q., Zhao, B., Zou, J., & Zhang, M. (2020) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.23528 · Cited by 13
Metadata
- Authors
- Lee, B.-L., New, A.-L., & Ong, C.-N.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-12-01
- Volume
- 49
- Issue
- 12
- Pages
- 2056-2066
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2031132826
- Cited by
- 104
- References
- 0
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.