Rapid Separation of LDL Subclasses by Iodixanol Gradient Ultracentrifugation
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Background: A predominance of small, dense LDL (sdLDL) confers in excess of a threefold increase in coronary heart disease (CHD) risk. The conventional method for the detection of sdLDL, salt density gradient ultracentrifugation (DGUC) has been superseded by more rapid techniques. This report presents novel methodology for the separation of sdLDL by a combination of iodixanol density gradient centrifugation and digital photography. Methods: LDL subclasses were separated in 3 h from prestained plasma on a self-forming density gradient of iodixanol. LDL subclass profiles were generated by digital photography and gel-scan software. Plasma samples from 106 normo- and dyslipidemic individuals were used to optimize the gradient for the resolution of LDL heterogeneity. A subgroup of 47 LDL profiles were then compared with LDL subclasses separated by salt DGUC. Results: The peak density of the predominant LDL band correlated significantly with the relative abundance (as a percentage) of sdLDL as resolved by salt DGUC (P <0.001). As shown previously, LDL isolated at a lighter density in iodixanol compared with salt gradients. A predominance of sdLDL corresponded to a peak density on iodixanol of 1.028 kg/L. This density and the area under the LDL profile lying above this density were sensitive and specific markers for the prediction of a predominance of sdLDL (P <0.001) and showed predictable associations with plasma triglycerides (r = 0.59; P <0.001) and HDL (r = −0.4; P <0.001). Conclusions: This simple method for the detection of sdLDL can differentiate a predominance of sdLDL, is highly reproducible, and can be used preparatively to isolate sdLDL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Low-Density Lipoprotein Subclass Patterns and Risk of Myocardial Infarction
Austin, M. A. (1988) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1988.03410130125037 · Cited by 1,780
Metabolic origins and clinical significance of LDL heterogeneity
Berneis, K. K., & Krauss, R. M. (2002) · Journal of Lipid Research · doi:10.1194/jlr.r200004-jlr200 · Cited by 896 · cited 1×
“Discussion A predominance of sdLDL is inextricably linked to increased risk of CHD and forms a major component of an atherogenic lipoprotein phenotype found in the metabolic syndrome and type II diabetes (1, 2).”
BackgroundGardner, C. D. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110029028 · Cited by 843
Griffin, B. A., Freeman, D. J., Tait, G. W., Thomson, J., Caslake, M. J., Packard, C. J., & Shepherd, J. (1994) · Atherosclerosis · doi:10.1016/0021-9150(94)90129-5 · Cited by 525
Self-citation
Cited by
Small Dense Low‐Density Lipoprotein as Biomarker for Atherosclerotic Diseases
Ivanova, E. A., Myasoedova, V. A., Melnichenko, A. A., Grechko, A. V., & Orekhov, A. N. (2017) · Oxidative Medicine and Cellular Longevity · doi:10.1155/2017/1273042 · Cited by 457
Hong, B. S., Cho, J.-H., Kim, H., Choi, E.-J., Rho, S., Kim, J., Kim, J. H., Choi, D.-S., Kim, Y.-K., Hwang, D., et al. (2009) · BMC Genomics · doi:10.1186/1471-2164-10-556 · Cited by 443
Jebb, S. A., Lovegrove, J. A., Griffin, B. A., Frost, G. S., Moore, C. S., Chatfield, M. D., Bluck, L. J., Williams, C. M., & Sanders, T. A. (2010) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2009.29096 · Cited by 192
“Plasma apolipoprotein B and A1 were measured by immunoprecipitation assays (Randox Laboratories, Crumlin, United Kingdom) on an ILAB-650 analyzer (Instrumentation Laboratory, Warrington, United Kingdom), and the proportion of small dense LDL (sdLDL) was measured by ultracentrifugation on the LDL fraction on an iodixan…”
MethodSelf-citationMorgan, L., Griffin, B., Millward, D., DeLooy, A., Fox, K., Baic, S., Bonham, M., Wallace, J., MacDonald, I., Taylor, M., et al. (2009) · Public Health Nutrition · doi:10.1017/s1368980008003236 · Cited by 115
“determined by iodixanol density gradient centrifugation as previously described((20,21)).”
MethodSelf-citationMason, R. P., & Sherratt, S. C. R. (2017) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2016.12.127 · Cited by 108
“sdLDL fractions were isolated from the plasma of healthy human volunteers by iodixanol gradient ultracentrifugation and adjusted to a final apolipoprotein (apoB100) concentration of 10mg/mL [27].”
Method
Metadata
- Authors
- Davies, I. G., Graham, J. M., & Griffin, B. A.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-11-01
- Volume
- 49
- Issue
- 11
- Pages
- 1865-1872
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2112711391
- Cited by
- 57
- References
- 4
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.