Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 245

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Determination of Folate Vitamers in Human Serum by Stable-Isotope-Dilution Tandem Mass Spectrometry and Comparison with Radioassay and Microbiologic Assay

Pfeiffer, Christine M, Fazili, Zia, McCoy, Les, Zhang, Ming, Gunter, Elaine W · 2004 · Clinical Chemistry

Abstract

Background: Current clinical methods for folate give different results and cannot measure the various forms of folate. We developed an isotope-dilution tandem mass spectrometric method coupled to liquid chromatography (LC/MS/MS) as a candidate reference method for 5-methyltetrahydrofolic acid (5MeTHF), 5-formyltetrahydrofolic acid (5FoTHF), and folic acid (FA) in human serum. Methods: We quantitatively isolated folates from 275 μL of serum with a phenyl solid-phase extraction cartridge, then detected and quantified them in stabilized serum extracts by positive-ion electrospray ionization LC/MS/MS. We used an isocratic mobile phase of acetic acid in organic solvent on a C8 analytical column. 13C-labeled folates were used as internal standards. Results: Limits of detection in serum were 0.13 (5MeTHF), 0.05 (5FoTHF), and 0.07 (FA) nmol/L. Within- and between-run imprecision (CV) was <7% for 5MeTHF and <10% for 5FoTHF at concentrations >0.5 nmol/L, and <10% for FA at concentrations >2.0 nmol/L. Total folate (TFOL) concentrations determined by competitive protein binding radioassay were ∼9% lower than results obtained with LC/MS/MS. The microbiologic assay gave ∼15% higher TFOL results with FA calibrator and no difference with 5MeTHF calibrator. The mean (SD) [range] TFOL in 42 sera was 35.5 (17.8) [6.5–75.6] nmol/L. Thirty-two samples with TFOL <50 nmol/L had, on average, 93.3% 5MeTHF, 2.3% FA, and 4.4% 5FoTHF. Ten samples with TFOL >50 nmol/L had, on average, 81.7% 5MeTHF, 15.7% FA, and 2.5% 5FoTHF. Conclusions: This stable-isotope-dilution LC/MS/MS method can quantify 5MeTHF, 5FoTHF, and FA in serum. Currently used clinical assays agree with this candidate reference method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2003.026955

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 245

Metadata

Authors
Pfeiffer, C. M., Fazili, Z., McCoy, L., Zhang, M., & Gunter, E. W.
Venue
Clinical Chemistry
Published
2004-02-01
Volume
50
Issue
2
Pages
423-432
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2071208072
Cited by
245
References
2
FWCI
6.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.