Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 162

The DOI matches its Crossref record.

Molecular Heterogeneity Has a Major Impact on the Measurement of Circulating N-Terminal Fragments of A- and B-Type Natriuretic Peptides

Ala-Kopsala, Minna, Magga, Jarkko, Peuhkurinen, Keijo, Leipälä, Jaana, Ruskoaho, Heikki, Leppäluoto, Juhani, Vuolteenaho, Olli · 2004 · Clinical Chemistry

Abstract

Background: The N-terminal fragments of A- and B-type natriuretic peptides (NT-proANP and NT-proBNP) are powerful markers of cardiac function. The current assays require refinement with regard to standardization with native calibrators and the ability to detect the actual circulating forms. Methods: The following peptides were prepared with recombinant methods: NT-proANP, NT-proBNP, proBNP1–108, and Tyr0-proBNP77–108. Fifteen peptides of 13–22 amino acids, spanning the sequences of NT-proANP and NT-proBNP, were prepared by solid-phase peptide synthesis. Two immunoassays for NT-proANP and four for NT-proBNP were set up, each with a different epitope specificity. The assays were applied for the measurement of NT-proANP and NT-proBNP in healthy individuals and in patients with acute myocardial infarction. The circulating molecular forms were analyzed by gel-filtration and reversed-phase HPLC. Results: According to the HPLC analyses, circulating NT-proANP consists mainly of the full-length peptide, with some degradation at both ends. In contrast, circulating NT-proBNP is very heterogeneous. Most immunoreactive NT-proBNP is significantly smaller in size than NT-proBNP1–76, with truncation at both termini. The smallest fragments can be detected by assays directed at the central part of NT-proBNP only; assays directed at the ends gave 30–40% lower values. Despite the difference, the various assays correlated reasonably well with each other (r2 = 0.77–0.85). In patients with acute myocardial infarction, NT-proANP and NT-proBNP concentrations were 1.8–2.3 and 4.2–4.5 times higher than in healthy individuals. The development of heart failure further increased the concentrations. Conclusions: Molecular heterogeneity of the circulating forms causes a serious risk of preanalytical errors in assays for NT-proBNP and, to a lesser extent, NT-proANP. The development of a sandwich assay for NT-proBNP would be especially challenging. The most robust and reliable assays use antibodies directed at the central portions of NT-proANP or NT-proBNP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2004.032490

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 162

Metadata

Authors
Ala-Kopsala, M., Magga, J., Peuhkurinen, K., Leipälä, J., Ruskoaho, H., Leppäluoto, J., & Vuolteenaho, O.
Venue
Clinical Chemistry
Published
2004-09-01
Volume
50
Issue
9
Pages
1576-1588
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2140855501
Cited by
162
References
0
FWCI
7.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Molecular Heterogeneity Has a Major Impact on the Measurement of Circulating N-Terminal Fragments of A- and B-Type Natriuretic Peptides. https://app.cochat.ai/papers/10.1373/clinchem.2004.032490
The paper
Ala-Kopsala, M., Magga, J., Peuhkurinen, K., Leipälä, J., Ruskoaho, H., Leppäluoto, J., & Vuolteenaho, O. (2004). Molecular Heterogeneity Has a Major Impact on the Measurement of Circulating N-Terminal Fragments of A- and B-Type Natriuretic Peptides. Clinical Chemistry. https://doi.org/10.1373/clinchem.2004.032490

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.