CoChat

Measurement of Urinary d- and l-2-Hydroxyglutarate Enantiomers by Stable-Isotope-Dilution Liquid Chromatography–Tandem Mass Spectrometry after Derivatization with Diacetyl-l-Tartaric Anhydride

Struys, Eduard A, Jansen, Erwin E W, Verhoeven, Nanda M, Jakobs, Cornelis · 2004 · Clinical Chemistry
Cited by 146

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: The differential diagnosis of d-2-hydroxyglutaric aciduria (d-2-HGA), l-2-hydroxyglutaric aciduria (l-2-HGA), and the combined d/l-2-hydroxyglutaric aciduria (d/l-2-HGA) can be accomplished only by the measurement of the corresponding 2-hydroxyglutarate (2-HG). Available methods for the determination of d- and l-2-HG in urine are either time-consuming and expensive or have not been extensively validated. We aimed to develop a method for their rapid and sensitive measurement. Methods: We used liquid chromatography–tandem mass spectrometry (LC-MS/MS) for the determination of d- and l-2-HG with stable-isotope-labeled internal standards. Urine samples of 20 μL were mixed with 250 μL of methanol containing the internal standards and subsequently dried under nitrogen. The analytes were derivatized by use of diacetyl-l-tartaric anhydride (DATAN) to obtain diastereomers, which were separated on an achiral C18 HPLC column and detected by MS/MS in multiple-reaction-monitoring mode. Results: The use of DATAN as chiral derivatization reagent provided very well separated peaks of the formed diastereomers of d- and l-2-HG, with a total runtime of 5 min. The inter- and intraassay CVs for d- and l-2-HG ranged from 3.4% to 6.2%. Mean recoveries of d- and l-2-HG, evaluated on two concentrations, were 94%. Detection limit of the presented method was 20 pmol for a sample volume of 20 μL. Method comparison of the LC-MS/MS method with a gas chromatography–mass spectrometry method, in which d- and l-2-HG were derivatized with R-(−)-butanol, showed good agreement between the two methods. Conclusions: Urinary d- and l-2-HG can be analyzed by MS/MS after derivatization with DATAN. The presented method may be suitable for the differential diagnosis of 2-HGA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2004.033399

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 146

Metadata

Authors
Struys, E. A., Jansen, E. E. W., Verhoeven, N. M., & Jakobs, C.
Venue
Clinical Chemistry
Published
2004-08-01
Volume
50
Issue
8
Pages
1391-1395
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2087360892
Cited by
146
References
2
FWCI
0.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of Urinary d- and l-2-Hydroxyglutarate Enantiomers by Stable-Isotope-Dilution Liquid Chromatography–Tandem Mass Spectrometry after Derivatization with Diacetyl-l-Tartaric Anhydride. https://app.cochat.ai/papers/10.1373/clinchem.2004.033399
The paper
Struys, E. A., Jansen, E. E. W., Verhoeven, N. M., & Jakobs, C. (2004). Measurement of Urinary d- and l-2-Hydroxyglutarate Enantiomers by Stable-Isotope-Dilution Liquid Chromatography–Tandem Mass Spectrometry after Derivatization with Diacetyl-l-Tartaric Anhydride. Clinical Chemistry. https://doi.org/10.1373/clinchem.2004.033399

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.