CoChat

Negative Interference in Cardiac Troponin I Immunoassays by Circulating Troponin Autoantibodies

Eriksson, Susann, Halenius, Heidi, Pulkki, Kari, Hellman, Jukka, Pettersson, Kim · 2005 · Clinical Chemistry
Cited by 126

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: There are numerous potential sources of interference in immunoassays. Our aim was to identify the blood component that causes negative interference in cardiac troponin I (cTnI) immunoassays based on antibodies against the central part of cTnI. Methods: We isolated an interfering factor (IF) from a sample with low recovery of added cTnI, using several consecutive purification steps: caprylic acid precipitation, ammonium sulfate precipitation, and purification on Cibacron Blue gel and protein G columns. Purified IF was identified by gel electrophoresis and mass spectrometric analysis of protein bands. For the direct detection of human antibodies to cardiac troponin in serum samples, we developed immunoassays using three different anti-human immunoglobulin antibodies and measured troponin antibodies in samples with low and normal cTnI recovery. Results: Treatment with caprylic acid did not precipitate IF, but IF precipitated at 40% ammonium sulfate saturation. IF bound to a Cibacron Blue gel column, from which it was eluted with a linear salt gradient; it also bound to protein G. Gel electrophoresis of purified IF showed two major bands with molecular masses corresponding to the heavy (∼50 kDa) and light chains (∼25 kDa) of immunoglobulin, and their identities were confirmed by mass spectrometry. The presence of troponin-specific autoantibodies was confirmed in samples with low recoveries of cTnI by three different immunoassays. The median signals were significantly higher in 10 samples with low recovery than in 10 samples with normal recovery of cTnI (P ≤ 0.007). Conclusions: Circulating autoantibodies to cTnI or other proteins of the troponin complex can be a source of negative interference in cTnI immunoassays.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2004.040063

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 126

Metadata

Authors
Eriksson, S., Halenius, H., Pulkki, K., Hellman, J., & Pettersson, K.
Venue
Clinical Chemistry
Published
2005-05-01
Volume
51
Issue
5
Pages
839-847
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1967595093
Cited by
126
References
3
FWCI
4.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Negative Interference in Cardiac Troponin I Immunoassays by Circulating Troponin Autoantibodies. https://app.cochat.ai/papers/10.1373/clinchem.2004.040063
The paper
Eriksson, S., Halenius, H., Pulkki, K., Hellman, J., & Pettersson, K. (2005). Negative Interference in Cardiac Troponin I Immunoassays by Circulating Troponin Autoantibodies. Clinical Chemistry. https://doi.org/10.1373/clinchem.2004.040063

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.