CoChat

Testosterone Measurement by Isotope-Dilution Liquid Chromatography–Tandem Mass Spectrometry: Validation of a Method for Routine Clinical Practice

Open access
Cawood, Marion L, Field, Helen P, Ford, Clive G, Gillingwater, Scott, Kicman, Andrew, Cowan, David, Barth, Julian H · 2005 · Clinical Chemistry
Cited by 154

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Immunoassay is unsatisfactory for measuring the testosterone concentrations typically found in women. Bench-top tandem mass spectrometers are a viable alternative technology for measurements in the clinical laboratory. Methods: We used stable-isotope dilution liquid chromatography–tandem mass spectrometry (ID/LC-MS/MS) to measure testosterone in plasma and serum. The sample volume was 50 μL in duplicate; preparation and analysis were carried out in a single tube, and a batch of 192 tubes was analyzed in 17.5 h. Results: Intra- and interassay imprecision was <15% in the range 0.3–49 nmol/L. Recovery of testosterone added to samples at concentrations of 0.625–20 nmol/L was 96% (CV = 12%; n = 26). Six samples were serially diluted with double charcoal-stripped serum to demonstrate linearity. Correlation (r2) with isotope-dilution gas chromatography–mass spectrometry for 20 pools of clinical samples (range, 0.5–38.5 nmol/L) was 0.99. Correlations with our extraction RIA were 0.97 for clinical samples from men (range, 8–46.3 nmol/L) and 0.66 for samples from women (range, 0.7–3.0 nmol/L), but were 0.35 for male samples containing <3 nmol/L testosterone and 0.77 for female samples containing >8 nmol/L. Various steroids added to double charcoal-stripped serum showed no interference at the retention time of the testosterone peak. Conclusions: The ID/LC-MS/MS method has improved accuracy compared with immunoassay. The low sample volume and simplicity, rapidity, and robustness of the method make it suitable for use as a high-throughput assay in routine clinical biochemistry laboratories.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2004.044503

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 154

Metadata

Authors
Cawood, M. L., Field, H. P., Ford, C. G., Gillingwater, S., Kicman, A., Cowan, D., & Barth, J. H.
Venue
Clinical Chemistry
Published
2005-08-01
Volume
51
Issue
8
Pages
1472-1479
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2168015482
Cited by
154
References
2
FWCI
7.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Testosterone Measurement by Isotope-Dilution Liquid Chromatography–Tandem Mass Spectrometry: Validation of a Method for Routine Clinical Practice. https://app.cochat.ai/papers/10.1373/clinchem.2004.044503
The paper
Cawood, M. L., Field, H. P., Ford, C. G., Gillingwater, S., Kicman, A., Cowan, D., & Barth, J. H. (2005). Testosterone Measurement by Isotope-Dilution Liquid Chromatography–Tandem Mass Spectrometry: Validation of a Method for Routine Clinical Practice. Clinical Chemistry. https://doi.org/10.1373/clinchem.2004.044503

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.