Abstract
Measurement of glycohemoglobin (GHb) is widely used in patients with diabetes mellitus as a monitor of long-term glycemic control (1)(2)(3). In addition, prospective randomized clinical trials, most notably the Diabetes Control and Complications Trial (DCCT) and the United Kingdom Prospective Diabetes Study (UKPDS), have demonstrated that GHb is a measure of the risk for the development of diabetes complications (4)(5). GHb is therefore an integral component of the management of patients with diabetes. GHb comprises several different hemoglobin-glucose adducts, including hemoglobin A1a (HbA1a), HbA1b, and HbA1c. More than 30 different methods are commercially available to measure GHb. Together these factors have led to considerable variation in reference intervals and results reported by different laboratories. When the DCCT was published in 1993, the lack of standardization of GHb methods produced very wide variability among methods, with values ranging from 4.0% to 8.1% on the same blood sample (6). In the United States, the NGSP (previously known as the National Glycohemoglobin Standardization Program) has reduced interlaboratory variation (7). Using a standardization process based on the DCCT reference method, the NGSP has promoted a dramatic improvement in comparability of GHb values among laboratories (3). Data from the 2003 GH2 survey from the College of American Pathologists indicated that ≥98% of participating laboratories use NGSP-certified methods and report results as HbA1c or HbA1c equivalents (3). Analogous standardization programs in Sweden and Japan (8)(9), established to harmonize GHb results, have also reduced variability among GHb results. More recently, the IFCC Working Group on HbA1c Standardization prepared primary reference materials of pure HbA1c and HbA0 and developed a reference method for HbA1c (10). They defined HbA1c as the stable adduct of glucose to the N-terminal valine of the β-chain of hemoglobin. In the reference method, hemoglobin is cleaved by endoproteinase Glu-C. The resulting glycated and nonglycated N-terminal hexapeptides are separated by HPLC, followed by quantification by electrospray ionization mass spectrometry or capillary electrophoresis (10). HbA1c is measured as the ratio of glycated to nonglycated N-terminal peptide and is reported as a percentage. Comparison of pooled blood samples revealed a linear relationship between HbA1c results of the IFCC reference method and the standardization schemes in the United States, Japan, and Sweden (11). For example, the calculated regression equation for NGSP ...
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Self-citationHoelzel, W., Weykamp, C., Jeppsson, J.-O., Miedema, K., Barr, J. R., Goodall, I., Hoshino, T., John, W. G., Kobold, U., Little, R., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.024802 · Cited by 690
Approved IFCC reference method for the measurement of HbA1c in human blood
Jeppsson, J.-O., Kobold, U., Barr, J., Finke, A., Hoelzel, W., Hoshino, T., Miedema, K., Mosca, A., Mauri, P., Paroni, R., et al. (2002) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2002.016 · Cited by 655
Cited by
Translating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
Daneman, D. (2006) · The Lancet · doi:10.1016/s0140-6736(06)68341-4 · Cited by 921
HbA 1c as a screening tool for detection of Type 2 diabetes: a systematic review
Bennett, C. M., Guo, M., & Dharmage, S. C. (2007) · Diabetic Medicine · doi:10.1111/j.1464-5491.2007.02106.x · Cited by 534
A new look at screening and diagnosing diabetes mellitus
Saudek, C. D., Herman, W. H., Sacks, D. B., Bergenstal, R. M., Edelman, D., & Davidson, M. B. (2008) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2007-2174 · Cited by 432
Self-citationAssessing Glycemia in Diabetes Using Self-monitoring Blood Glucose and Hemoglobin A 1c
Saudek, C. D., Derr, R. L., & Kalyani, R. R. (2006) · JAMA · doi:10.1001/jama.295.14.1688 · Cited by 373
Metadata
- Authors
- Sacks, D. B.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-02-03
- Volume
- 51
- Issue
- 4
- Pages
- 681-683
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2003207506
- Cited by
- 94
- References
- 3
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.