CoChat

Global Harmonization of Hemoglobin A1c

Sacks, D. B. · 2005 · Clinical Chemistry
Cited by 94

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Measurement of glycohemoglobin (GHb) is widely used in patients with diabetes mellitus as a monitor of long-term glycemic control (1)(2)(3). In addition, prospective randomized clinical trials, most notably the Diabetes Control and Complications Trial (DCCT) and the United Kingdom Prospective Diabetes Study (UKPDS), have demonstrated that GHb is a measure of the risk for the development of diabetes complications (4)(5). GHb is therefore an integral component of the management of patients with diabetes. GHb comprises several different hemoglobin-glucose adducts, including hemoglobin A1a (HbA1a), HbA1b, and HbA1c. More than 30 different methods are commercially available to measure GHb. Together these factors have led to considerable variation in reference intervals and results reported by different laboratories. When the DCCT was published in 1993, the lack of standardization of GHb methods produced very wide variability among methods, with values ranging from 4.0% to 8.1% on the same blood sample (6). In the United States, the NGSP (previously known as the National Glycohemoglobin Standardization Program) has reduced interlaboratory variation (7). Using a standardization process based on the DCCT reference method, the NGSP has promoted a dramatic improvement in comparability of GHb values among laboratories (3). Data from the 2003 GH2 survey from the College of American Pathologists indicated that ≥98% of participating laboratories use NGSP-certified methods and report results as HbA1c or HbA1c equivalents (3). Analogous standardization programs in Sweden and Japan (8)(9), established to harmonize GHb results, have also reduced variability among GHb results. More recently, the IFCC Working Group on HbA1c Standardization prepared primary reference materials of pure HbA1c and HbA0 and developed a reference method for HbA1c (10). They defined HbA1c as the stable adduct of glucose to the N-terminal valine of the β-chain of hemoglobin. In the reference method, hemoglobin is cleaved by endoproteinase Glu-C. The resulting glycated and nonglycated N-terminal hexapeptides are separated by HPLC, followed by quantification by electrospray ionization mass spectrometry or capillary electrophoresis (10). HbA1c is measured as the ratio of glycated to nonglycated N-terminal peptide and is reported as a percentage. Comparison of pooled blood samples revealed a linear relationship between HbA1c results of the IFCC reference method and the standardization schemes in the United States, Japan, and Sweden (11). For example, the calculated regression equation for NGSP ...

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2004.047431

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 94

Metadata

Authors
Sacks, D. B.
Venue
Clinical Chemistry
Published
2005-02-03
Volume
51
Issue
4
Pages
681-683
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2003207506
Cited by
94
References
3
FWCI
5.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.