CoChat

Falsely Low Urinary Albumin Concentrations after Prolonged Frozen Storage of Urine Samples

Brinkman, Jacoline W, de Zeeuw, Dick, Duker, Jacko J, Gansevoort, Ronald T, Kema, Ido P, Hillege, Hans L, de Jong, Paul E, Bakker, Stephan JL · 2005 · Clinical Chemistry
Cited by 65

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Microalbuminuria, defined as a urinary albumin concentration (UAC) of 20–200 mg/L, is an early predictor of diabetic nephropathy (1)(2)(3)(4)(5)(6). In addition, microalbuminuria is a marker of cardiovascular morbidity and mortality, both in patients with diabetes mellitus and in the general population(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17). Consequently, there is great interest in screening for microalbuminuria in these groups. In cohort studies, urine samples are often kept frozen at −20 °C before analysis. Although some study results have indicated no effect of freezing on UAC(18)(19)(20)(21)(22)(23), other studies have found erroneously low values when samples were frozen at −20 °C(24)(25)(26)(27). Only a few studies have investigated the effect of longer storage periods, but these studies were small, and samples were in the macroalbuminuric range (>200 mg/L). We investigated the effects of storage at −20 °C for up to 24 months, mixing methods, and baseline UAC on samples in the normo- and microalbuminuric ranges. Urine samples were collected during the prospective PREVEND study in the general population initiated to investigate urinary albumin excretion as a predictor of renal and cardiovascular disease (28). The participants were asked to collect urine for two 24-h periods and to store it in two 3-L plastic containers at 7 °C and deliver it within 2 days to the clinic. Immediately after delivery, the urine sample volume was determined, and a portion of each of the 24-h samples was stored in 2-mL polypropylene aliquots at −20 °C for albumin assessment after freezing. For measurement of UAC in fresh samples, portions were kept at 7 °C in 10-mL polystyrene tubes until the UAC was measured.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2005.053777

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 65

Metadata

Authors
Brinkman, J. W., de Zeeuw, D., Duker, J. J., Gansevoort, R. T., Kema, I. P., Hillege, H. L., de Jong, P. E., & Bakker, S. J.
Venue
Clinical Chemistry
Published
2005-11-01
Volume
51
Issue
11
Pages
2181-2183
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2085895890
Cited by
65
References
1
FWCI
2.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Falsely Low Urinary Albumin Concentrations after Prolonged Frozen Storage of Urine Samples. https://app.cochat.ai/papers/10.1373/clinchem.2005.053777
The paper
Brinkman, J. W., de Zeeuw, D., Duker, J. J., Gansevoort, R. T., Kema, I. P., Hillege, H. L., de Jong, P. E., & Bakker, S. J. (2005). Falsely Low Urinary Albumin Concentrations after Prolonged Frozen Storage of Urine Samples. Clinical Chemistry. https://doi.org/10.1373/clinchem.2005.053777

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.