CoChat

Feasibility of Standardization of Serum C-Peptide Immunoassays with Isotope-Dilution Liquid Chromatography–Tandem Mass Spectrometry

Rodríguez Cabaleiro, Diego, Stöckl, Dietmar, Kaufman, Jean M, Fiers, Tom, Thienpont, Linda M · 2006 · Clinical Chemistry
Cited by 44

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Serum C-peptide concentrations reflect pancreatic function in different clinical and diagnostic settings; however, the utility of C-peptide testing is limited by the lack of standardized commercial immunoassays. Standardization can best be done by split-sample comparison with a hierarchically higher reference measurement procedure with a set of native sera. For serum peptides, isotope-dilution liquid chromatography–mass spectrometry (ID-LC/MS) is recommended as a reference measurement procedure. Methods: We evaluated the analytical performance characteristics of an ID-LC/tandem MS procedure for measurement of serum C-peptide after a 2-step solid-phase extraction. To investigate the feasibility of this procedure for use in standardization, we also performed a method comparison with 3 representative commercial assays. Results: The ID-LC/tandem MS procedure showed maximum within-run, between-run, and total CVs on dedicated sera (C-peptide concentrations, 1.6 and 4.0 μg/L) of 2.1%, 2.5%, and 2.9%, respectively; an accuracy of 94.6%–104.1%; a minimum trueness of 98.1% (95% confidence interval, 96.2%–100.0%), and limits of quantification and detection of 0.15 and 0.03 μg/L, respectively. Deming linear regression analysis of the method-comparison data showed that the immunoassays correlated well with ID-MS and were specific, but lacked intercomparability and trueness. We propose that the deficiencies can be resolved by recalibration on the basis of the method comparison. Conclusions: The ID-LC/tandem MS procedure is suitable for specific and accurate measurement of basal and stimulated serum concentrations of proinsulin C-peptide fragment 33–63 and is suitable for use in standardization of C-peptide immunoassays.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2005.062505

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 44

Metadata

Authors
Rodríguez Cabaleiro, D., Stöckl, D., Kaufman, J. M., Fiers, T., & Thienpont, L. M.
Venue
Clinical Chemistry
Published
2006-06-01
Volume
52
Issue
6
Pages
1193-1196
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2100525274
Cited by
44
References
2
FWCI
1.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Feasibility of Standardization of Serum C-Peptide Immunoassays with Isotope-Dilution Liquid Chromatography–Tandem Mass Spectrometry. https://app.cochat.ai/papers/10.1373/clinchem.2005.062505
The paper
Rodríguez Cabaleiro, D., Stöckl, D., Kaufman, J. M., Fiers, T., & Thienpont, L. M. (2006). Feasibility of Standardization of Serum C-Peptide Immunoassays with Isotope-Dilution Liquid Chromatography–Tandem Mass Spectrometry. Clinical Chemistry. https://doi.org/10.1373/clinchem.2005.062505

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.