CoChat

Ultrasensitive Monitoring of HIV-1 Viral Load by a Low-Cost Real-Time Reverse Transcription-PCR Assay with Internal Control for the 5′ Long Terminal Repeat Domain

Open access
Drosten, Christian, Panning, Marcus, Drexler, Jan Felix, Hänsel, Florian, Pedroso, Celia, Yeats, Jane, de Souza Luna, Luciano Kleber, Samuel, Matthew, Liedigk, Britta, Lippert, Ute, Stürmer, Martin, Doerr, Hans Wilhelm, Brites, Carlos, Preiser, Wolfgang · 2006 · Clinical Chemistry
Cited by 97

The DOI matches its Crossref record.

Abstract

Background: Current HIV-1 viral-load assays are too expensive for resource-limited settings. In some countries, monitoring of antiretroviral therapy is now more expensive than treatment itself. In addition, some commercial assays have shown shortcomings in quantifying rare genotypes. Methods: We evaluated real-time reverse transcription-PCR with internal control targeting the conserved long terminal repeat (LTR) domain of HIV-1 on reference panels and patient samples from Brazil (n = 1186), South Africa (n = 130), India (n = 44), and Germany (n = 127). Results: The detection limit was 31.9 IU of HIV-1 RNA/mL of plasma (>95% probability of detection, Probit analysis). The internal control showed inhibition in 3.7% of samples (95% confidence interval, 2.32%–5.9%; n = 454; 40 different runs). Comparative qualitative testing yielded the following: Roche Amplicor vs LTR assay (n = 431 samples), 51.7% vs 65% positives; Amplicor Ultrasensitive vs LTR (n = 133), 81.2% vs 82.7%; BioMerieux NucliSens HIV-1 QT (n = 453), 60.5% vs 65.1%; Bayer Versant 3.0 (n = 433), 57.7% vs 55.4%; total (n = 1450), 59.0% vs 63.8% positives. Intra-/interassay variability at medium and near-negative concentrations was 18%–51%. The quantification range was 50–10 000 000 IU/mL. Viral loads for subtypes A–D, F–J, AE, and AG yielded mean differences of 0.31 log10 compared with Amplicor in the 103–104 IU/mL range. HIV-1 N and O were not detected by Amplicor, but yielded up to 180 180.00 IU/mL in the LTR assay. Viral loads in stored samples from all countries, compared with Amplicor, NucliSens, or Versant, yielded regression line slopes (SD) of 0.9 (0.13) (P <0.001 for all). Conclusions: This method offers all features of commercial assays and covers all relevant genotypes. It could allow general monitoring of antiretroviral therapy in resource-limited settings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2006.066498

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Drosten, C., Panning, M., Drexler, J. F., Hänsel, F., Pedroso, C., Yeats, J., de Souza Luna, L. K., Samuel, M., Liedigk, B., Lippert, U., Stürmer, M., Doerr, H. W., Brites, C., & Preiser, W.
Venue
Clinical Chemistry
Published
2006-07-01
Volume
52
Issue
7
Pages
1258-1266
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2139652458
Cited by
97
References
0
FWCI
4.12
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.