Whole Genome Amplification and Genetic Analysis after Extraction of Proteins from Dried Blood Spots
The DOI matches its Crossref record.
Abstract
Programs to screen newborns for congenital disorders are based on analysis of dried blood spot samples (DBSS), which have proven to be robust and convenient for collection, transport, and storage. Because blood samples are collected with no selection, and coverage of the population is essentially universal, residual DBSS combined with patient registers are a valuable resource for epidemiological research (1). The usefulness of DBSS is limited by the small amount of blood available, however, and methods that optimize the use of the sample are required, such as various whole genome amplification (WGA) methods used in genetic epidemiological studies (2)(3). We previously described a high-capacity multiplex immunoassay, based on Luminex xMAP technology that uses two 3-mm punches from each DBSS, for simultaneous determination of 25 inflammatory markers and neurotrophins (4). We now report that after extraction of proteins for the immunoassays, there is sufficient genomic DNA (gDNA) on the used DBSS disks to perform several WGA reactions, each producing enough whole–genome-amplified DNA (wgaDNA) for numerous reliable genotypings. Blood from 20 anonymous volunteers was spotted on filter paper and air dried, and six 3-mm disks were punched out from each DBSS. Half the disks were subjected to protein extraction (4). The 2 groups of disks from each individual were then further split into 2 subgroups with, respectively, 1 and 2 disks in each, and gDNA was extracted in a volume of 200 μL using the Extract-N-Amp™ reagent set (Sigma-Aldrich). The concentration of gDNA (0.2 mg/L, measured by the Quant-IT™ PicoGreen® dsDNA Reagent) was not correlated to the use of 1 or 2 disks or to prior protein extraction. We then amplified extracted gDNA with 2 different WGA reagent sets: the GenomePlex Whole Genome Amplification Kit (Sigma-Aldrich), which is based on the Omniplex method, and the AmpliQ Genomic Amplifier Kit (Ampliqon), which uses the multiple-displacement amplification approach. Allowed input volumes are 10 μL for the GenomePlex (∼2.0 ng gDNA) and 8 μL for the AmpliQ, (∼1.6 ng gDNA). Both reagent sets use less input gDNA than the recommended 10 ng, a feature that may be critical for the genotyping performance of the resulting wgaDNA (5), and thus direct comparisons cannot be made. The yield of wgaDNA was 2.6–3.8 μg, independent of whether protein extraction was performed and whether 1 or 2 disks were used. The quality of wgaDNA was assessed by TaqMan® single-nucleotide polymorphism (SNP) genotyping of 27 SNPs in 27 genes distributed on 13 chromosomes. Reference gDNA was extracted from 200 μL of whole blood from the same 20 individuals. Genotype calls were done independently by 3 persons. The call and error rates are shown in Table 11 . Despite the suboptimal amount of input gDNA, the best call and error rates were nearly optimal. The most common errors, results indicating that heterozygous individuals were homozygous, were attributable to allele dropouts most probably due to an insufficient amount or low quality of template gDNA. Details of sample flow and call and error rates for each individual gene can be seen in the Data Supplement that accompanies the online version of this article at http://www.clinchem.org/content/vol53/issue5. When extraction of proteins from disks was performed before extraction of DNA, the resulting wgaDNA generally showed higher TaqMan genotype call rates and lower error rates than wgaDNA from disks that had not undergone pre-extraction of proteins (Table 11 ). This result suggests that the pre-extraction procedure removes compounds from the filter paper disks that may interfere with the WGA reaction. This explanation is in accordance with the observation that the use of 2 disks that had not undergone protein pre-extraction gave inferior results than did the use of only 1 disk, whereas the opposite was the case for the pre-extracted disks, for which the use of 2 disks instead of 1 yielded superior results (Table 11 ). The DBSS used in this study were stored for only a limited time, and we do not know the effect on the quality of wgaDNA of prolonged storage at room temperature or at −20 °C. Our results demonstrate that DBSS disks previously used for multiplex protein measurements are reliable sources of gDNA that is suitable for WGA and SNP genotyping. The study also shows that both the Omniplex-based method producing short wgaDNA of 400–500 bp and the multiple-displacement amplification-based method producing long wgaDNA of 10–20 kbp are well suited for the amplification. In our setup, the amount of template gDNA from each extraction was sufficient for ∼20 amplifications, and the yield of wgaDNA from 1 amplification was enough for ∼300 TaqMan genotypings. TaqMan call and error rates of wgaDNA from DBSS disks. Pre-extracted disks were subjected to protein extraction prior to DNA extraction. TaqMan call and error rates of wgaDNA from DBSS disks. Pre-extracted disks were subjected to protein ex
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Storage policies and use of the Danish Newborn Screening Biobank
Nørgaard‐Pedersen, B., & Hougaard, D. M. (2007) · Journal of Inherited Metabolic Disease · doi:10.1007/s10545-007-0631-x · Cited by 257
Self-citationiPSYCH-Broad Consortium, Satterstrom, F. K., Walters, R. K., Singh, T., Wigdor, E. M., Lescai, F., Demontis, D., Kosmicki, J. A., Grove, J., Stevens, C., et al. (2019) · Nature Neuroscience · doi:10.1038/s41593-019-0527-8 · Cited by 209
Self-citationErlangsen, A., Appadurai, V., Wang, Y., Turecki, G., Mors, O., Werge, T., Mortensen, P. B., Starnawska, A., Børglum, A. D., Schork, A., et al. (2020) · Molecular Psychiatry · doi:10.1038/s41380-018-0218-y · Cited by 157
Self-citationGenome-wide scans using archived neonatal dried blood spot samples
Hollegaard, M. V., Grauholm, J., Børglum, A., Nyegaard, M., Nørgaard-Pedersen, B., Ørntoft, T., Mortensen, P. B., Wiuf, C., Mors, O., Didriksen, M., et al. (2009) · BMC Genomics · doi:10.1186/1471-2164-10-297 · Cited by 89
Self-citationRobustness of genome-wide scanning using archived dried blood spot samples as a DNA source
Hollegaard, M. V., Grove, J., Grauholm, J., Kreiner-Møller, E., Bønnelykke, K., Nørgaard, M., Benfield, T. L., Nørgaard-Pedersen, B., Mortensen, P. B., Mors, O., et al. (2011) · BMC Genetics · doi:10.1186/1471-2156-12-58 · Cited by 83
Self-citation
Metadata
- Authors
- Hollegaard, M. V., Sørensen, K. M., Petersen, H. K., Arnardottir, M. B., Nørgaard-Pedersen, B., Thorsen, P., & Hougaard, D. M.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-06-01
- Volume
- 53
- Issue
- 6
- Pages
- 1161-1162
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2113045250
- Cited by
- 23
- References
- 0
- FWCI
- 0.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.