Rapid Cortisol Assay during Adrenal Vein Sampling in Patients with Primary Aldosteronism
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Adrenal vein sampling is considered the gold standard test to identify primary aldosteronism, the most frequent form of secondary hypertension. Technical difficulties with this procedure may be overcome by monitoring cortisol concentrations in the different sampling sites during catheterization. Methods: We applied a rapid automated cortisol assay performed on a benchtop immunoassay analyzer near the operating suite during the catheterization procedures in 5 hypertensive patients. A mean of 7.8 samples (range, 5–13) were collected from the vena cava as well as from right and left adrenal veins. Results: Cortisol concentrations measured by the rapid assay and by our routine method were comparable. Two of 5 patients were found to be affected by an aldosterone-producing adenoma and 3 of 5 by a bilateral adrenal hyperplasia. Cortisol determination during the adrenal vein sampling procedure allowed a successful cannulation in all patients, including a patient in whom it was necessary to cannulate 9 different candidate right adrenal veins before finding the correct one. Conclusions: Intraoperative cortisol assays appeared safe, reproducible, simple to perform, rapid, and cost-effective. The approach represents a service-oriented model for the laboratory and can provide valuable and timely information for improving the success rate of adrenal vein catheterization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Mulatero (2004) · doi:10.1210/jc.2003-031337 · Cited by 961
Cited by
Funder, J. W., Carey, R. M., Mantero, F., Murad, M. H., Reincke, M., Shibata, H., Stowasser, M., & Young, W. F. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-4061 · Cited by 2,925
Funder, J. W., Carey, R. M., Fardella, C., Gomez-Sanchez, C. E., Mantero, F., Stowasser, M., Young, W. F., & Montori, V. M. (2008) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-0104 · Cited by 1,554
Clinical Practice Guidelines for Multiple Endocrine Neoplasia Type 1 (MEN1)
Thakker, R. V., Newey, P. J., Walls, G. V., Bilezikian, J., Dralle, H., Ebeling, P. R., Melmed, S., Sakurai, A., Tonelli, F., & Brandi, M. L. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-1230 · Cited by 1,477
Francis, G. L., Waguespack, S. G., Bauer, A. J., Angelos, P., Benvenga, S., Cerutti, J. M., Dinauer, C. A., Hamilton, J., Hay, I. D., Luster, M., et al. (2015) · Thyroid · doi:10.1089/thy.2014.0460 · Cited by 1,238
Rossi, G. P., Auchus, R. J., Brown, M., Lenders, J. W. M., Naruse, M., Plouin, P. F., Satoh, F., & Young, W. F. (2014) · Hypertension · doi:10.1161/hypertensionaha.113.02097 · Cited by 613
Laboratory challenges in primary aldosteronism screening and diagnosis
Rehan, M., Raizman, J. E., Cavalier, E., Don-Wauchope, A. C., & Holmes, D. T. (2015) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2015.01.003 · Cited by 89
Metadata
- Authors
- Mengozzi, G., Rossato, D., Bertello, C., Garrone, C., Milan, A., Pagni, R., Veglio, F., & Mulatero, P.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-11-01
- Volume
- 53
- Issue
- 11
- Pages
- 1968-1971
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2024647057
- Cited by
- 107
- References
- 2
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.