Direct Determination of Lipoprotein Particle Sizes and Concentrations by Ion Mobility Analysis

Caulfield, Michael P, Li, Shuguang, Lee, Gloria, Blanche, Patricia J, Salameh, Wael A, Benner, W Henry, Reitz, Richard E, Krauss, Ronald M · 2008 · Clinical Chemistry

Abstract

Background: Current methods for measuring the concentrations of lipoprotein particles and their distributions in particle subpopulations are not standardized. We describe here and validate a new gas-phase differential electrophoretic macromolecular mobility-based method (ion mobility, or IM) for direct quantification of lipoprotein particles, from small, dense HDL to large, buoyant, very-low-density lipoprotein (VLDL). Methods: After an ultracentrifugation step to remove albumin, we determined the size and concentrations of lipoprotein particles in serum samples using IM. Scan time is 2 min and covers a particle range of 17.2–540.0 Å. After scanning, data are pooled by totaling the particle number across a predetermined size range that corresponds to particular lipoprotein subclasses. IM results were correlated with those of standard methods for cholesterol and apolipoprotein analysis. Results: Intra- and interassay coefficients of variation for LDL particle size were <1.0%. The intra- and interassay variation for LDL and HDL particle subfraction measurements was <20%. IM-measured non-HDL correlated well with apolipoprotein B (r = 0.92). Conclusions: The IM method provides accurate, reproducible, direct determination of size and concentration for a broad range of lipoprotein particles. Use of this methodology in studies of patients with cardiovascular disease and other pathologic states will permit testing of its clinical utility for risk assessment and management of these conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2007.100586

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 227

Metadata

Authors
Caulfield, M. P., Li, S., Lee, G., Blanche, P. J., Salameh, W. A., Benner, W. H., Reitz, R. E., & Krauss, R. M.
Venue
Clinical Chemistry
Published
2008-08-01
Volume
54
Issue
8
Pages
1307-1316
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2053585701
Cited by
227
References
5
FWCI
9.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Direct Determination of Lipoprotein Particle Sizes and Concentrations by Ion Mobility Analysis. https://app.cochat.ai/papers/10.1373/clinchem.2007.100586
The paper
Caulfield, M. P., Li, S., Lee, G., Blanche, P. J., Salameh, W. A., Benner, W. H., Reitz, R. E., & Krauss, R. M. (2008). Direct Determination of Lipoprotein Particle Sizes and Concentrations by Ion Mobility Analysis. Clinical Chemistry. https://doi.org/10.1373/clinchem.2007.100586

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.