Background: Glycohemoglobin (GHB), reported as hemoglobin (Hb) A1c, is a marker of long-term glycemic control in patients with diabetes and is directly related to risk for diabetic complications. HbE and HbD are the second and fourth most common Hb variants worldwide. We investigated the accuracy of HbA1c measurement in the presence of HbE and/or HbD traits. Methods: We evaluated 23 HbA1c methods; 9 were immunoassay methods, 10 were ion-exchange HPLC methods, and 4 were capillary electrophoresis, affinity chromatography, or enzymatic methods. An overall test of coincidence of 2 least-squares linear regression lines was performed to determine whether the presence of HbE or HbD traits caused a statistically significant difference from HbAA results relative to the boronate affinity HPLC comparative method. Deming regression analysis was performed to determine whether the presence of these traits produced a clinically significant effect on HbA1c results with the use of ±10% relative bias at 6% and 9% HbA1c as evaluation limits. Results: Statistically significant differences were found in more than half of the methods tested. Only 22% and 13% showed clinically significant interference for HbE and HbD traits, respectively. Conclusions: Some current HbA1c methods show clinically significant interferences with samples containing HbE or HbD traits. To avoid reporting of inaccurate results, ion-exchange chromatograms must be carefully examined to identify possible interference from these Hb variants. For some methods, manufacturers’ instructions do not provide adequate information for making correct decisions about reporting results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2008.103580

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 130

Metadata

Authors
Little, R. R., Rohlfing, C. L., Hanson, S., Connolly, S., Higgins, T., Weykamp, C. W., D'Costa, M., Luzzi, V., Owen, W. E., & Roberts, W. L.
Venue
Clinical Chemistry
Published
2008-08-01
Volume
54
Issue
8
Pages
1277-1282
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2136662420
Cited by
130
References
1
FWCI
5.23
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of Hemoglobin (Hb) E and HbD Traits on Measurements of Glycated Hb (HbA1c) by 23 Methods. https://app.cochat.ai/papers/10.1373/clinchem.2008.103580
The paper
Little, R. R., Rohlfing, C. L., Hanson, S., Connolly, S., Higgins, T., Weykamp, C. W., D'Costa, M., Luzzi, V., Owen, W. E., & Roberts, W. L. (2008). Effects of Hemoglobin (Hb) E and HbD Traits on Measurements of Glycated Hb (HbA1c) by 23 Methods. Clinical Chemistry. https://doi.org/10.1373/clinchem.2008.103580

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.