The DOI matches its Crossref record; 126 of the 126 references it cites were found in a registry or an index.
Oral Fluid Testing for Drugs of Abuse
Open accessAbstract
Background: Oral fluid (OF) is an exciting alternative matrix for monitoring drugs of abuse in workplace, clinical toxicology, criminal justice, and driving under the influence of drugs (DUID) programs. During the last 5 years, scientific and technological advances in OF collection, point-of-collection testing devices, and screening and confirmation methods were achieved. Guidelines were proposed for workplace OF testing by the Substance Abuse and Mental Health Services Administration, DUID testing by the European Union’s Driving under the Influence of Drugs, Alcohol and Medicines (DRUID) program, and standardization of DUID research. Although OF testing is now commonplace in many monitoring programs, the greatest current limitation is the scarcity of controlled drug administration studies available to guide interpretation. Content: This review outlines OF testing advantages and limitations, and the progress in OF that has occurred during the last 5 years in collection, screening, confirmation, and interpretation of cannabinoids, opioids, amphetamines, cocaine, and benzodiazepines. We examine controlled drug administration studies, immunoassay and chromatographic methods, collection devices, point-of-collection testing device performance, and recent applications of OF testing. Summary: Substance Abuse and Mental Health Services Administration approval of OF testing was delayed because questions about drug OF disposition were not yet resolved, and collection device performance and testing assays required improvement. Here, we document the many advances achieved in the use of OF. Additional research is needed to identify new biomarkers, determine drug detection windows, characterize OF adulteration techniques, and evaluate analyte stability. Nevertheless, there is no doubt that OF offers multiple advantages as an alternative matrix for drug monitoring and has an important role in DUID, treatment, workplace, and criminal justice programs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The rate of diffusion is affected by several factors including lipophilicity of the drug, salivary pH, pKa, molecular size, un-ionized free drug blood concentration and membrane characteristics (8–11).”
From Recommendations for Toxicological Investigation of Drug-Impaired Driving and Motor Vehicle Fatalities—2021 Update (2021) · cites this paper as [8]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Recent developments within the field of forensic toxicology include increased interest in the use of oral fluid as a specimen for drug detection in impaired driving cases (8).”
From Recommendations for Toxicological Investigation of Drug-Impaired Driving and Motor Vehicle Fatalities—2021 Update (2021) · cites this paper as [8]
The cited source says what the claim attributes to it.
In the citing paper
“Drug deposition into oral fluid is via passive diffusion of un-ionized free drug from the blood through the salivary glands and ion trapping of basic drugs in the oral cavity.”
From Recommendations for Toxicological Investigation of Drug-Impaired Driving and Motor Vehicle Fatalities—2021 Update (2021) · cites this paper as [8]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dams, R., Huestis, M. A., Lambert, W. E., & Murphy, C. M. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00574-9 · Cited by 601
Self-citationRamaekers, J. G., Moeller, M. R., van Ruitenbeek, P., Theunissen, E. L., Schneider, E., & Kauert, G. F. (2006) · Drug and Alcohol Dependence · doi:10.1016/j.drugalcdep.2006.03.015 · Cited by 290
Schepers, R. J., Oyler, J. M., Joseph, R. E., Cone, E. J., Moolchan, E. T., & Huestis, M. A. (2003) · Clinical Chemistry · doi:10.1373/49.1.121 · Cited by 259
Self-citationOral fluid collection: the neglected variable in oral fluid testing
Crouch, D. J. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2005.02.028 · Cited by 228
Niedbala, R. S., Kardos, K. W., Fritch, D., Kardos, S., Fries, T., Waga, J., Robb, J. T., & Cone, E. J. (2001) · Journal of Analytical Toxicology · doi:10.1093/jat/25.5.289 · Cited by 218
Bush, D. M. (2007) · Forensic Science International · doi:10.1016/j.forsciint.2007.03.008 · Cited by 210
Huestis, M. A., & Cone, E. J. (2004) · Journal of Analytical Toxicology · doi:10.1093/jat/28.6.394 · Cited by 208
Self-citationThe role of alternative specimens in toxicological analysis
Gallardo, E., & Queiroz, J. A. (2008) · Biomedical Chromatography · doi:10.1002/bmc.1009 · Cited by 207
Interpretation of Oral Fluid Tests for Drugs of Abuse
Cone, E. J., & Huestis, M. A. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1384.037 · Cited by 200
Self-citationCone, E. J. (1990) · Journal of Analytical Toxicology · doi:10.1093/jat/14.1.1 · Cited by 189
Verstraete, A. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2004.11.023 · Cited by 184
Physicians’ perspectives on prescribing benzodiazepines for older adults: a qualitative study
Cook, J. M., Marshall, R., Masci, C., & Coyne, J. C. (2007) · Journal of General Internal Medicine · doi:10.1007/s11606-006-0021-3 · Cited by 178
Drug Testing in Oral Fluid—Evaluation of Sample Collection Devices
Langel, K., Engblom, C., Pehrsson, A., Gunnar, T., Ariniemi, K., & Lillsunde, P. M. (2008) · Journal of Analytical Toxicology · doi:10.1093/jat/32.6.393 · Cited by 174
Guidelines for research on drugged driving
Walsh, J., Verstraete, A., Huestis, M. A., & Mørland, J. G. (2008) · Addiction · doi:10.1111/j.1360-0443.2008.02277.x · Cited by 170
Self-citationToennes, S. W., Kauert, G. F., Steinmeyer, S., & Moeller, M. R. (2004) · Forensic Science International · doi:10.1016/j.forsciint.2004.08.002 · Cited by 168
Drug Screening of Preserved Oral Fluid by Liquid Chromatography–Tandem Mass Spectrometry
Øiestad, E. L., Johansen, U., & Christophersen, A. S. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2006.074237 · Cited by 167
Oral fluid as a diagnostic tool
Choo, R. E., & Huestis, M. A. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.248 · Cited by 163
Self-citationMaurer, H. H. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2774-z · Cited by 153
Pujadas, M., Pichini, S., Civit, E., Santamariña, E., Pérez, K., & de la Torre, R. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.02.022 · Cited by 136
Chen, Z., Somogyi, A., Reynolds, G., & Bochner, F. (1991) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.1991.tb05550.x · Cited by 136
Drugs in oral fluid in randomly selected drivers
Drummer, O. H., Gerostamoulos, D., Chu, M., Swann, P., Boorman, M., & Cairns, I. (2007) · Forensic Science International · doi:10.1016/j.forsciint.2007.03.028 · Cited by 133
Wood, M., Laloup, M., Fernández, M. D. M. R., Jenkins, K. M., Young, M. S., Ramaekers, J. G., Boeck, G. D., & Samyn, N. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2004.11.027 · Cited by 129
Prevalence of alcohol and drugs among Norwegian motor vehicle drivers: A roadside survey
Gjerde, H., Normann, P. T., Pettersen, B., Assum, T., Aldrin, M., Johansen, U., Kristoffersen, L., Øiestad, E. L., Christophersen, A. S., & Mørland, J. G. (2008) · Accident Analysis & Prevention · doi:10.1016/j.aap.2008.06.015 · Cited by 124
Toennes, S. W., Steinmeyer, S., Maurer, H. J., Moeller, M. R., & Kauert, G. F. (2005) · Journal of Analytical Toxicology · doi:10.1093/jat/29.1.22 · Cited by 122
Recent applications of liquid chromatography–mass spectrometry in forensic science
Wood, M., Laloup, M., Samyn, N., Fernández, M. D. M. R., de Bruijn, E. A., Maes, R. A. A., & Boeck, G. D. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.04.084 · Cited by 121
Gunnar, T., Ariniemi, K., & Lillsunde, P. M. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.846 · Cited by 117
Osterloh, J. (1993) · Clinical Pharmacokinetics · doi:10.2165/00003088-199324050-00001 · Cited by 116
Passive Cannabis Smoke Exposure and Oral Fluid Testing
Niedbala, S., Kardos, K. W., Salamone, S. J., Fritch, D., Bronsgeest, M., & Cone, E. J. (2004) · Journal of Analytical Toxicology · doi:10.1093/jat/28.7.546 · Cited by 112
Kolbrich, E. A., Barnes, A. J., Gorelick, D. A., Boyd, S. J., Cone, E. J., & Huestis, M. A. (2006) · Journal of Analytical Toxicology · doi:10.1093/jat/30.8.501 · Cited by 107
Self-citationPharmacokinetic Properties of 9-Tetrahydrocannabinol in Serum and Oral Fluid
Kauert, G. F., Ramaekers, J. G., Schneider, E., Moeller, M. R., & Toennes, S. W. (2007) · Journal of Analytical Toxicology · doi:10.1093/jat/31.5.288 · Cited by 106
Concheiro, M., de Castro, A., Quintela, O., Cruz, A., & López‐Rivadulla, M. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2135-4 · Cited by 102
Plasma and Oral Fluid Pharmacokinetics and Pharmacodynamics after Oral Codeine Administration
Kim, I., Barnes, A. J., Oyler, J. M., Schepers, R. J., Joseph, R. E., Cone, E. J., Lafko, D., Moolchan, E. T., & Huestis, M. A. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.9.1486 · Cited by 101
Self-citationNiedbala, R. S., Kardos, K. W., Fritch, D., Kunsman, K., Blum, K., Newland, G. A., Waga, J., Kurtz, L., Bronsgeest, M., & Cone, E. J. (2005) · Journal of Analytical Toxicology · doi:10.1093/jat/29.7.607 · Cited by 100
Methamphetamine Disposition in Oral Fluid, Plasma, and Urine
Huestis, M. A., & Cone, E. J. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1384.038 · Cited by 96
Self-citationMulticlass analysis of illicit drugs in plasma and oral fluids by LC-MS/MS
Sergi, M., Bafile, E., Compagnone, D., Curini, R., D'Ascenzo, G., & Romolo, F. S. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2456-3 · Cited by 92
Screening and confirmatory method for benzodiazepines and hypnotics in oral fluid by LC-MS/MS
Kintz, P., Villain, M., Concheiro, M., & Cirimele, V. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2004.12.040 · Cited by 92
Wylie, F. M., Torrance, H. J., Anderson, R. A., & Oliver, J. S. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2005.02.024 · Cited by 89
Teixeira, H. M., Verstraete, A., Proença, P., Corte-Real, F., Monsanto, P. V., & Vieira, D. N. (2007) · Forensic Science International · doi:10.1016/j.forsciint.2007.03.026 · Cited by 89
Dams, R., Choo, R. E., Lambert, W. E., Jones, H. E., & Huestis, M. A. (2006) · Drug and Alcohol Dependence · doi:10.1016/j.drugalcdep.2006.08.020 · Cited by 88
Self-citationDams, R., Murphy, C. M., Choo, R. E., Lambert, W. E., Leenheer, A. P. D., & Huestis, M. A. (2003) · Analytical Chemistry · doi:10.1021/ac026111t · Cited by 87
Self-citationThe Effects of Collection Methods On Oral Fluid Codeine Concentrations
O'Neal, C. L., Crouch, D. J., Rollins, D. E., & Fatah, A. A. (2000) · Journal of Analytical Toxicology · doi:10.1093/jat/24.7.536 · Cited by 86
The Determination of Morphine in Urine and Oral Fluid Following Ingestion of Poppy Seeds
Rohrig, T. P., & Moore, C. M. (2003) · Journal of Analytical Toxicology · doi:10.1093/jat/27.7.449 · Cited by 84
Kankaanpää, A., Gunnar, T., Ariniemi, K., Lillsunde, P. M., Mykkänen, S., & Seppαlä, T. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.07.035 · Cited by 83
Pehrsson, A., Gunnar, T., Engblom, C., Seppä, H., Jama, A., & Lillsunde, P. M. (2007) · Forensic Science International · doi:10.1016/j.forsciint.2007.05.022 · Cited by 74
Laloup, M., Fernández, M. D. M. R., Wood, M., Maes, V. A., Boeck, G. D., Vanbeckevoort, Y., & Samyn, N. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1297-9 · Cited by 71
Ojaniemi, K., Lintonen, T., Impinen, A. O., Lillsunde, P. M., & Ostamo, A. I. (2008) · Accident Analysis & Prevention · doi:10.1016/j.aap.2008.10.011 · Cited by 70
Recovery of Drugs of Abuse from the Immunalysis Quantisal Oral Fluid Collection Device
Quintela, O., Crouch, D. J., & Andrenyak, D. M. (2006) · Journal of Analytical Toxicology · doi:10.1093/jat/30.8.614 · Cited by 70
Moore, C. M., Rana, S., & Coulter, C. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2007.02.016 · Cited by 68
Confirmation by LC–MS of drugs in oral fluid obtained from roadside testing
Concheiro, M., de Castro, A., Quintela, O., Cruz, A., & López‐Rivadulla, M. (2007) · Forensic Science International · doi:10.1016/j.forsciint.2007.03.034 · Cited by 67
Laloup, M., Fernández, M. D. M. R., Wood, M., Boeck, G. D., Maes, V. A., & Samyn, N. (2006) · Forensic Science International · doi:10.1016/j.forsciint.2006.03.033 · Cited by 66
O'Neal, C. L., Crouch, D. J., Rollins, D. E., Fatah, A. A. M., & Cheever, M. L. (1999) · Journal of Analytical Toxicology · doi:10.1093/jat/23.6.452 · Cited by 66
Quintela, O., Cruz, A., de Castro, A., Concheiro, M., & López‐Rivadulla, M. (2005) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.12.038 · Cited by 65
Teixeira, H. M., Proença, P., Verstraete, A., Corte-Real, F., & Vieira, D. N. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2004.11.026 · Cited by 65
Moore, C. M., Rana, S., & Coulter, C. (2006) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.12.008 · Cited by 65
Samyn, N., Boeck, G. D., Cirimele, V., Verstraete, A., & Kintz, P. (2002) · Journal of Analytical Toxicology · doi:10.1093/jat/26.4.211 · Cited by 62
Prevalence and Disposition of Drugs of Abuse and Opioid Treatment Drugs in Oral Fluid
Cone, E. J., Clarke, J., & Tsanaclis, L. (2007) · Journal of Analytical Toxicology · doi:10.1093/jat/31.8.424 · Cited by 62
Bioanalytical procedures for determination of drugs of abuse in oral fluid
Samyn, N., Laloup, M., & Boeck, G. D. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1245-8 · Cited by 60
Bretaudière, J. P., Vassault, A. J., Amsellem, L., Pourci, M. L., Phung, H. T., & Bailly, M. (1977) · Clinical Chemistry · doi:10.1093/clinchem/23.12.2263 · Cited by 60
Wylie, F. M., Torrance, H. J., Seymour, A., Buttress, S., & Oliver, J. S. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2005.02.025 · Cited by 59
Concheiro, M., de Castro, A., Quintela, O., López‐Rivadulla, M., & Cruz, A. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2004.12.041 · Cited by 59
Laloup, M., Fernández, M. D. M. R., Wood, M., Boeck, G. D., Henquet, C., Maes, V. A., & Samyn, N. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.03.031 · Cited by 58
Kauert, G. F., Iwersen‐Bergmann, S., & Toennes, S. W. (2006) · Journal of Analytical Toxicology · doi:10.1093/jat/30.4.274 · Cited by 56
Moore, C. M., Coulter, C., Rana, S., Vincent, M., & Snares, J. (2006) · Journal of Analytical Toxicology · doi:10.1093/jat/30.7.409 · Cited by 55
Detection of THCA in Oral Fluid by GC-MS-MS
Day, D., Kuntz, D. J., Feldman, M., & Presley, L. C. (2006) · Journal of Analytical Toxicology · doi:10.1093/jat/30.9.645 · Cited by 55
The National Institute on Drug Abuse:
Durell, J. (1983) · Advances in Alcohol & Substance Abuse · doi:10.1300/j251v02n03_05 · Cited by 55
Laloup, M., Tilman, G., Maes, V. A., Boeck, G. D., Wallemacq, P. E., Ramaekers, J. G., & Samyn, N. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2005.04.019 · Cited by 53
Principles of Bone Biology, 3rd ed.
(2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1712 · Cited by 53
Link, B., Haschke, M., Wenk, M., & Krähenbühl, S. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2987 · Cited by 52
Concheiro, M., de Castro, A., Quintela, O., Cruz, A., & López‐Rivadulla, M. (2004) · Journal of Chromatography B · doi:10.1016/j.jchromb.2004.08.017 · Cited by 51
Apollonio, L. G., Whittall, I. R., Pianca, D. J., Kyd, J. M., & Maher, W. A. (2007) · Journal of Analytical Toxicology · doi:10.1093/jat/31.4.208 · Cited by 51
Rosita-2 project: final report
Verstraete, A., & Raes, E. (2006) · Ghent University Academic Bibliography (Ghent University) · Cited by 50
Effect of Repeated Cocaine Administration on Detection Times in Oral Fluid and Urine
Jufer, R. A., WALSH, S. L., Cone, E. J., & Sampson-Cone, A. (2006) · Journal of Analytical Toxicology · doi:10.1093/jat/30.7.458 · Cited by 50
Scheidweiler, K. B., & Huestis, M. A. (2006) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.03.020 · Cited by 48
Self-citationCognard, E., Bouchonnet, S., & Staub, C. (2006) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2006.01.041 · Cited by 48
Oral fluid drug tests: Effects of adulterants and foodstuffs
Wong, R. C., Tran, M., & Tung, J. K. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2005.02.023 · Cited by 48
Quintela, O., Andrenyak, D. M., Hoggan, A. M., & Crouch, D. J. (2007) · Journal of Analytical Toxicology · doi:10.1093/jat/31.3.157 · Cited by 47
The recovery of illicit drugs from oral fluid sampling devices
Dickson, S. J., Park, A., Nolan, S. L., Kenworthy, S., Nicholson, C., Midgley, J., Pinfold, R., & Hampton, S. (2006) · Forensic Science International · doi:10.1016/j.forsciint.2006.03.004 · Cited by 47
Determination of Benzodiazepines in Oral Fluid Using LC-MS-MS
Moore, C. M., Coulter, C., Crompton, K., & Zumwalt, M. C. (2007) · Journal of Analytical Toxicology · doi:10.1093/jat/31.9.596 · Cited by 47
Kala, S. V., Harris, S. E., Freijo, T. D., & Gerlich, S. (2008) · Journal of Analytical Toxicology · doi:10.1093/jat/32.8.605 · Cited by 46
An Evaluation of Selected Oral Fluid Point-of-Collection Drug-Testing Devices
Crouch, D. J., Walsh, J., Flegel, R. R., Cangianelli, L., Baudys, J., & Atkins, R. (2005) · Journal of Analytical Toxicology · doi:10.1093/jat/29.4.244 · Cited by 46
Clauwaert, K. M., Decaestecker, T. N., Mortier, K. A., Lambert, W. E., Deforce, D. L. D., Peteghem, C. V., & Bocxlaer, J. V. (2004) · Journal of Analytical Toxicology · doi:10.1093/jat/28.8.655 · Cited by 46
Drugs in injured drivers in Denmark
Bernhoft, I. M., Steentoft, A., Johansen, S. S., Klitgaard, N. A., Larsen, L. B., & Hansen, L. B. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2004.12.039 · Cited by 45
Detection of Conjugated 11-nor- 9-Tetrahydrocannabinol-9-carboxylic Acid in Oral Fluid
Moore, C. M., Rana, S., Coulter, C., Day, D., Vincent, M., & Soares, J. R. (2007) · Journal of Analytical Toxicology · doi:10.1093/jat/31.4.187 · Cited by 45
Engblom, C., Gunnar, T., Rantanen, A., & Lillsunde, P. M. (2007) · Journal of Analytical Toxicology · doi:10.1093/jat/31.5.276 · Cited by 44
Smink, B. E., Mathijssen, M., Lusthof, K. J., de Gier, J. J., Egberts, T. C. G., & Uges, D. R. A. (2006) · Journal of Analytical Toxicology · doi:10.1093/jat/30.7.478 · Cited by 44
Crouch, D. J., Walsh, J., Cangianelli, L., & Quintela, O. (2008) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e3181679249 · Cited by 43
Kacinko, S. L., Barnes, A. J., Kim, I., Moolchan, E. T., Wilson, L., Cooper, G. A. A., Reid, C., Baldwin, D., Hand, C., & Huestis, M. A. (2004) · Forensic Science International · doi:10.1016/j.forsciint.2003.12.003 · Cited by 43
Self-citationSimultaneous Analysis of 14 Benzodiazepines in Oral Fluid by Solid-Phase Extraction and LC-MS-MS
Ngwa, G., Fritch, D., Blum, K., & Newland, G. (2007) · Journal of Analytical Toxicology · doi:10.1093/jat/31.7.369 · Cited by 43
Moore, C. M., Ross, W., Coulter, C., Adams, L., Rana, S., Vincent, M., & Soares, J. R. (2006) · Journal of Analytical Toxicology · doi:10.1093/jat/30.7.413 · Cited by 43
Barnes, A. J., Kim, I., Schepers, R. J., Moolchan, E. T., Wilson, L., Cooper, G. A. A., Reid, C., Hand, C. W., & Huestis, M. A. (2003) · Journal of Analytical Toxicology · doi:10.1093/jat/27.7.402 · Cited by 43
Self-citationBlind Trials of an Onsite Saliva Drug Test for Marijuana and Opiates
JEHANLI, A. M. T., Brannan, S., Moore, L., & Spiehler, V. R. (2001) · Journal of Forensic Sciences · doi:10.1520/jfs15123j · Cited by 41
Uddin, M. N., Samanidou, V., & Papadoyannis, I. N. (2008) · Journal of Separation Science · doi:10.1002/jssc.200800342 · Cited by 41
Oral fluid testing for cannabis: On-site OraLine® IV s.a.t. device versus GC/MS
Cirimele, V., Villain, M., Mura, P., Bernard, M., & Kintz, P. (2006) · Forensic Science International · doi:10.1016/j.forsciint.2006.01.020 · Cited by 41
On-site testing of illicit drugs: the use of the drug-testing device “Toxiquick®”
Biermann, T., Schwarze, B., Zedler, B., & Betz, P. (2004) · Forensic Science International · doi:10.1016/j.forsciint.2004.01.013 · Cited by 40
Peters, F. T., Samyn, N., Kræmer, T., Riedel, W. J., & Maurer, H. H. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.081547 · Cited by 39
Evaluation of Ten Oral Fluid Point-of-Collection Drug-Testing Devices*
Walsh, J., Crouch, D. J., Danaceau, J. P., Cangianelli, L., Liddicoat, L. J., & Adkins, R. (2007) · Journal of Analytical Toxicology · doi:10.1093/jat/31.1.44 · Cited by 38
Quintela, O., Cruz, A., Concheiro, M., de Castro, A., & López‐Rivadulla, M. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1719 · Cited by 38
Smink, B. E., Hofman, B. J. A., Dijkhuizen, A., Lusthof, K. J., de Gier, J. J., Egberts, T. C. G., & Uges, D. R. A. (2008) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.2008.03252.x · Cited by 38
Kintz, P., Bernhard, W., Villain, M., Gasser, M., Aebi, B., & Cirimele, V. (2005) · Journal of Analytical Toxicology · doi:10.1093/jat/29.7.724 · Cited by 34
Sharp, M., Wallace, S. M., Hindmarsh, K. W., & Peel, H. W. (1983) · Journal of Analytical Toxicology · doi:10.1093/jat/7.1.11 · Cited by 33
Validation of the Cozart® Amphetamine Microplate EIA for the analysis of amphetamines in oral fluid
Cooper, G. A. A., Wilson, L., Reid, C., Hand, C., & Spiehler, V. R. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2005.06.011 · Cited by 31
Proficiency testing (external quality assessment) of drug detection in oral fluid
Clarke, J., & Wilson, J. F. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2004.11.025 · Cited by 31
Evaluation of the Cozart DDSV Test for Cannabis in Oral Fluid
Kintz, P., Brunet, B., Muller, J.-F., Serra, W., Villain, M., Cirimele, V., & Mura, P. (2009) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0b013e3181947916 · Cited by 30
Validation of the Cozart® microplate EIA for analysis of opiates in oral fluid
Cooper, G. A. A., Wilson, L., Reid, C., Baldwin, D., Hand, C., & Spiehler, V. R. (2004) · Forensic Science International · doi:10.1016/j.forsciint.2004.10.013 · Cited by 30
Kolbrich, E. A., Kim, I., Barnes, A. J., Moolchan, E. T., Wilson, L., Cooper, G. A. A., Reid, C., Baldwin, D., Hand, C. W., & Huestis, M. A. (2003) · Journal of Analytical Toxicology · doi:10.1093/jat/27.7.407 · Cited by 30
Self-citationWho makes the diagnosis? The role of clinical skills and diagnostic test results
Wahner‐Roedler, D. L., Chaliki, S. S., Bauer, B. A., Bundrick, J. B., Bergstrom, L., Lee, M. C., Cha, S. S., & Elkin, P. L. (2006) · Journal of Evaluation in Clinical Practice · doi:10.1111/j.1365-2753.2006.00691.x · Cited by 28
Teixeira, H. M., Proença, P., Castanheira, A., Santos, S. A. O., López‐Rivadulla, M., Corte-Real, F., Marques, E. P., & Vieira, D. N. (2004) · Forensic Science International · doi:10.1016/j.forsciint.2004.09.002 · Cited by 27
Acetylcodeine as a Marker of Illicit Heroin Abuse in Oral Fluid Samples
Phillips, S. G., & Allen, K. R. (2006) · Journal of Analytical Toxicology · doi:10.1093/jat/30.6.370 · Cited by 27
Evaluation of the Cozart® RapiScan drug test system for opiates and cocaine in oral fluid
Cooper, G. A. A., Wilson, L., Reid, C., Main, L., & Hand, C. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2004.12.042 · Cited by 26
Concheiro, M., de Castro, A., Quintela, O., et al. (2004) · Journal of Chromatography B · doi:10.1016/s1570-0232(04)00650-6 · Cited by 26
Development and validation of the Cozart® DDS oral fluid collection device
Speedy, T., Baldwin, D., Jowett, G., Gallina, M., & JEHANLI, A. M. T. (2007) · Forensic Science International · doi:10.1016/j.forsciint.2007.03.038 · Cited by 25
Martins, L. F., Yegles, M., & Wennig, R. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2007.11.001 · Cited by 25
New technology and new initiatives in U.S. workplace testing
Walsh, J. (2007) · Forensic Science International · doi:10.1016/j.forsciint.2007.03.011 · Cited by 25
Comparison of GC-MS and EIA Results for the Analysis of Methadone in Oral Fluid
Cooper, G. A. A., Wilson, L., Reid, C., Baldwin, D., Hand, C. W., & Spiehler, V. R. (2005) · Journal of Forensic Sciences · doi:10.1520/jfs2004539 · Cited by 24
Fernández, P., Morales, L., Vázquez, C., Lago, M., & Bermejo, A. M. (2008) · Journal of Applied Toxicology · doi:10.1002/jat.1365 · Cited by 23
Cámpora, P., Bermejo, A. M., Tabernero, M. J., & Fernández, P. (2006) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2449 · Cited by 23
Busto, U. E., Kaplan, H. L., Wright, C. E., Gomez‐Mancilla, B., Zawertailo, L. A., Greenblatt, D. J., & Sellers, E. M. (2000) · Journal of Clinical Psychopharmacology · doi:10.1097/00004714-200012000-00008 · Cited by 22
Kim, I., Barnes, A. J., Schepers, R. J., Moolchan, E. T., Wilson, L., Cooper, G. A. A., Reid, C., Hand, C., & Huestis, M. A. (2003) · Clinical Chemistry · doi:10.1373/49.9.1498 · Cited by 21
Self-citationPre-analytical stability of selected benzodiazepines on a polymeric oral fluid sampling device
Kempf, J., Wuske, T., Schubert, R., & Weinmann, W. (2009) · Forensic Science International · doi:10.1016/j.forsciint.2009.02.004 · Cited by 19
Validation of the Cozart(R) Microplate EIA for Cocaine and Metabolites in Oral Fluid
Cooper, G. A. A., Wilson, L., Reid, C., Baldwin, D., Hand, C., & Spieher, V. (2004) · Journal of Analytical Toxicology · doi:10.1093/jat/28.6.498 · Cited by 19
Buprenorphine detection in biological samples
Giovanni, N. D., Fucci, N., Scarlata, S., & Donzelli, G. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.235 · Cited by 15
Evaluation of a Rapid Oral Fluid Point-of-Care Test for MDMA
Wilson, L., JEHANLI, A. M. T., Hand, C. W., Cooper, G. A. A., & Smith, R. H. (2007) · Journal of Analytical Toxicology · doi:10.1093/jat/31.2.98 · Cited by 15
Determination of Propoxyphene in Oral Fluid
Rana, S., Moore, C. M., Vincent, M., Coulter, C., Agrawal, A., & Soares, J. R. (2006) · Journal of Analytical Toxicology · doi:10.1093/jat/30.8.516 · Cited by 9
Moore, C. M., Coulter, C., & Crompton, K. (2007) · Journal of Analytical Toxicology · doi:10.1093/jat/31.8.442 · Cited by 7
Diagnostic testing in the emergency department.
Flomenbaum, N., & Goldfrank, L. R. (1983) · PubMed · Cited by 3
Talasemi ve Hemoglobinopatilerin Moleküler Tanı Yöntemleri
Özkınay, F. (2010) · Turkiye Klinikleri Hematology - Special Topics · Cited by 2
Flagged first, then by citations
Research works printed but not linked: 11
- 2004, Clin Chem Lab Med, 42, 1273
- 2004, Federal Register, 69, 19673
- 1992, Can saliva THC levels be correlated to behavior?, p 190
- 2008 27–31, Simultaneous identification and quantification of Cannabis sativa cannabinoids and metabolites in oral fluid
- 2005, Clin Chem Lab Med, 43, 1377
- 2005 17–21, Saliva/plasma ratios of cocaine, ecgonine methyl ester and benzoylecgonine following controlled cocaine administration
- 2007 27–30, Toxicological analyses in the DRUID epidemiological studies: analytical methods, target analytes and analytical cut-offs
- 2007, Ther Drug Monit, 29, 493
- 2005, J Forensic Sci, 50, 928
- 2005 11, Monitoring of ecstasy (MDMA) and three metabolites in oral fluid
- 2005 2, Positive ion chemical ionization and gas chromatography/quadrupole mass spectrometry for confirmation and quantitation of benzoylecgonine in oral fluid
Cited by
Sorted by citations
Malamud, D. (2010) · Dental Clinics of North America · doi:10.1016/j.cden.2010.08.004 · Cited by 489
A Single-Question Screening Test for Drug Use in Primary Care
Smith, P. C., Schmidt, S. M., Allensworth‐Davies, D., & Saitz, R. (2010) · Archives of Internal Medicine · doi:10.1001/archinternmed.2010.140 · Cited by 486
Application of microfluidic chip technology in pharmaceutical analysis: A review
Cui, P., & Wang, S. (2018) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2018.12.001 · Cited by 401
Saliva sampling: Methods and devices. An overview
Bellagambi, F., Lomonaco, T., Salvo, P., Vivaldi, F., Hangouët, M., Ghimenti, S., Biagini, D., di Francesco, F., Fuoco, R., & Errachid, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115781 · Cited by 283
Cannabis effects on driving lateral control with and without alcohol
Hartman, R. L., Brown, T. L., Milavetz, G., Spurgin, A. L., Pierce, R. S., Gorelick, D. A., Gaffney, G., & Huestis, M. A. (2015) · Drug and Alcohol Dependence · doi:10.1016/j.drugalcdep.2015.06.015 · Cited by 251
Self-citation
Metadata
- Authors
- Bosker, W. M., & Huestis, M. A.
- Affiliations
- National Institutes of Health (US)
- Corresponding author
- Huestis, Marilyn A
- ORCID
- Huestis, Marilyn A
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-11-01
- Volume
- 55
- Issue
- 11
- Pages
- 1910-1931
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- PMC
- PMC3165054
- OpenAlex
- W2062866182
- Cited by
- 378
- References
- 125
- Citations by year
- 2026: 7 · 2025: 8 · 2024: 14 · 2023: 8 · 2022: 19 · 2021: 18 · 2020: 25 · 2019: 22 · 2018: 23 · 2017: 31 · 2016: 27 · 2015: 35 · 2014: 28 · 2013: 33 · 2012: 36
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- Clinical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health
- National Institute on Drug Abuse (ZIADA000412)
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Epidemiology › Substance Abuse Treatment and Outcomes
- Keywords
- oral fluid testing, drugs of abuse, drug testing, workplace drug testing, drug-impaired driving, cannabinoids, opioids, amphetamine, cocaine, benzodiazepines, analyte stability, immunoassay, chromatographic methods, drug monitoring
- MeSH terms
- Amphetamines, Analgesics, Opioid, Benzodiazepines, Cannabinoids, Cocaine, Humans, Saliva, Substance Abuse Detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review