Interlaboratory Variation in 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 Is Significantly Improved If Common Calibration Material Is Used
The DOI matches its Crossref record.
Abstract
Measurements of 25-hydroxyvitamin D2 (D2)1 and 25-hydroxyvitamin D3 (D3) are used to detect vitamin D deficiency and monitor vitamin D supplementation. Interlaboratory variation within the same method groups makes it impossible to apply standardized reference intervals or published clinical cutoff values. Laboratories therefore must develop site-specific reference intervals. Advances in the routine use of liquid chromatography–tandem mass spectrometry (LC-MS/MS) in clinical chemistry laboratories have enabled the development of methods for measuring D2 and D3 individually (1). Despite the superior performance of LC-MS/MS methods compared with HPLC and immunoassay approaches, an examination of the UK Vitamin D External Quality Assessment Scheme (DEQAS) data for the LC-MS/MS user group indicates that interlaboratory variation exists within this method group. Calibration of D2 and D3 assays has been a continuing problem because there is no certified reference material available to test method accuracy. A recent Letter to the Editor in this journal pointed out that calibration is not the only concern with vitamin D assays. Laboratories also do not have common standard operating procedures and use a wide variety of instrumentation (2). We used commercially available calibration material (Chromsystems, …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Global Consensus Recommendations on Prevention and Management of Nutritional Rickets
Munns, C. F., Shaw, N., Kiely, M., Specker, B. L., Thacher, T. D., Ozono, K., Michigami, T., Tiosano, D., Mughal, M. Z., Mäkitie, O., et al. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-2175 · Cited by 1,150
Therapeutic Drug Monitoring of Tacrolimus-Personalized Therapy: Second Consensus Report
Brunet, M., van Gelder, T., Åsberg, A., Haufroid, V., Hesselink, D. A., Langman, L., Lemaitre, F., Marquet, P., Seger, C., Shipkova, M., et al. (2019) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000640 · Cited by 707
Food allergy as a risk factor for nutritional rickets
Fox, A. T., Du Toit, G., Lang, A., & Lack, G. (2004) · Pediatric Allergy and Immunology · doi:10.1111/j.1399-3038.2004.00158.x · Cited by 576
Measuring cortisol in serum, urine and saliva—Are our assays good enough?
El-Farhan, N., Rees, D. A., & Evans, C. (2017) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/0004563216687335 · Cited by 395
Global Consensus Recommendations on Prevention and Management of Nutritional Rickets
Munns, C. F., Shaw, N., Kiely, M., Specker, B. L., Thacher, T. D., Ozono, K., Michigami, T., Tiosano, D., Mughal, M. Z., Mäkitie, O., et al. (2016) · Hormone Research in Paediatrics · doi:10.1159/000443136 · Cited by 349
Metadata
- Authors
- Yates, A. M., Bowron, A., Calton, L., Heynes, J., Field, H., Rainbow, S., & Keevil, B.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-12-01
- Volume
- 54
- Issue
- 12
- Pages
- 2082-2084
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1980197649
- Cited by
- 53
- References
- 0
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interlaboratory Variation in 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 Is Significantly Improved If Common Calibration Material Is Used. https://app.cochat.ai/papers/10.1373/clinchem.2008.110452
- The paper
- Yates, A. M., Bowron, A., Calton, L., Heynes, J., Field, H., Rainbow, S., & Keevil, B. (2008). Interlaboratory Variation in 25-Hydroxyvitamin D2 and 25-Hydroxyvitamin D3 Is Significantly Improved If Common Calibration Material Is Used. Clinical Chemistry. https://doi.org/10.1373/clinchem.2008.110452
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.