CoChat

Measurement of Aldosterone in Human Plasma by Semiautomated HPLC–Tandem Mass Spectrometry

Taylor, Paul J, Cooper, Donald P, Gordon, Richard D, Stowasser, Michael · 2009 · Clinical Chemistry
Cited by 118

The DOI matches its Crossref record.

Abstract

Background: Reliable measurement of aldosterone with less interlaboratory variation than RIA would help standardize testing for primary aldosteronism. We set out to validate a high-performance liquid chromatography–tandem mass spectrometry (HPLC-MS/MS) method for aldosterone in human plasma. Methods: We prepared samples (EDTA plasma, lithium heparin plasma, and serum from separator and plain clot tubes) and measured aldosterone using online HPLC-MS/MS with d7-aldosterone as internal standard. We also analyzed EDTA plasma samples by immunoassay. We established a reference range for HPLC-MS/MS aldosterone by analyzing blood collected midmorning from 97 normotensive seated subjects. Results: The linear range was 69.4–5548.0 pmol/L (2.5–200 ng/dL) (r2 > 0.994, n = 14). Inter- and intraday analytical recovery and imprecision for quality control samples of 166.4, 1109.6, and 4161.0 pmol/L (6.0, 40.0, and 150.0 ng/dL) were 92.2%–102.0% and <6.3%, respectively (n = 5). The lower limit of quantification was 69.4 pmol/L (2.5 ng/dL), with inter- and intraday analytical recovery and imprecision of 91.4%–94.5% and <9.5% (n = 5). No interferences were observed in plasma from Addison’s disease patients (n = 5). Comparison of collection tubes, using EDTA as the reference, revealed similar aldosterone results. Comparison of HPLC-MS/MS with immunoassay gave an acceptable mean bias (0.83%) but wide range (−44.8% to 39.7%) of differences. HPLC-MS/MS aldosterone concentrations in normotensive subjects ranged from <69.4 to 635.2 pmol/L (<2.5 to 22.9 ng/dL). Conclusions: This first reported aldosterone method using online HPLC-MS/MS is precise across the clinically relevant range, not influenced by collection tube type, and offers semiautomated sample preparation and high throughput.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2008.116004

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 118

Metadata

Authors
Taylor, P. J., Cooper, D. P., Gordon, R. D., & Stowasser, M.
Venue
Clinical Chemistry
Published
2009-06-01
Volume
55
Issue
6
Pages
1155-1162
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2137944309
Cited by
118
References
0
FWCI
5.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of Aldosterone in Human Plasma by Semiautomated HPLC–Tandem Mass Spectrometry. https://app.cochat.ai/papers/10.1373/clinchem.2008.116004
The paper
Taylor, P. J., Cooper, D. P., Gordon, R. D., & Stowasser, M. (2009). Measurement of Aldosterone in Human Plasma by Semiautomated HPLC–Tandem Mass Spectrometry. Clinical Chemistry. https://doi.org/10.1373/clinchem.2008.116004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.