Point: Legitimate and Illegitimate Tests of Free-Analyte Assay Function
The DOI matches its Crossref record.
Abstract
In the history of clinical immunoassay, even up to the present day, no group of tests has been subjected to more scrutiny and controversy than analog-type free-analyte assays (1)(2)(3)(4). Unfortunately, inappropriate design of many experiments has led users to an incorrect perspective of how analog assays work. An analysis of the important series of studies by Nelson and coworkers (5)(6)(7)(8)(9)(10) shows that most experiments were conducted outside the valid working limits of analog-type or 2-step free-analyte assays. Here we explore the legitimacy of this viewpoint. In gold-standard methods of equilibrium dialysis and ultrafiltration, free analyte is first separated from that bound to serum proteins. Only then is the free analyte measured by what essentially is a high-sensitivity total analyte assay. For these methods, testing of assay parameters such as recovery of added analyte, linearity of response, and cross-reactivity are legitimate, applying equally to total analyte measurements. When the antibody probe is in direct contact with serum, however, the situation is radically different. For bound thyroxine (T4), serum contains a low-concentration, high-affinity binding protein (thyroxine-binding globulin) and high-concentration, low-affinity proteins (transthyretin and albumin). Free and total analyte are nonlinearly related (except with zero-thyroxine-binding globulin serum) (11). Recovery and linearity experiments in such conditions are thus not feasible, becoming increasingly less accurate at higher thyroxine-binding globulin concentrations (11).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
TSH and thyrotropic agonists: key actors in thyroid homeostasis
Dietrich, J. W., Landgrafe, G., & Fotiadou, E. H. (2012) · Journal of Thyroid Research · doi:10.1155/2012/351864 · Cited by 146
Thienpont, L. M., Van Uytfanghe, K., Beastall, G., Faix, J. D., Ieiri, T., Miller, W. G., Nelson, J. C., Ronin, C., Ross, H. A., Thijssen, J. H., et al. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.140194 · Cited by 135
van Deventer, H. E., Mendu, D. R., Remaley, A. T., & Soldin, S. J. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.154088 · Cited by 108
Determination of free thyroid hormones
Thienpont, L. M., Van Uytfanghe, K., Poppe, K., & Velkeniers, B. (2013) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2013.05.012 · Cited by 102
Metadata
- Authors
- Midgley, J. E. M., & Christofides, N. D.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-03-01
- Volume
- 55
- Issue
- 3
- Pages
- 439-441
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2058455565
- Cited by
- 18
- References
- 0
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Point: Legitimate and Illegitimate Tests of Free-Analyte Assay Function. https://app.cochat.ai/papers/10.1373/clinchem.2008.116525
- The paper
- Midgley, J. E. M., & Christofides, N. D. (2009). Point: Legitimate and Illegitimate Tests of Free-Analyte Assay Function. Clinical Chemistry. https://doi.org/10.1373/clinchem.2008.116525
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.