CoChat

Tracking of High-Sensitivity C-Reactive Protein after an Initially Elevated Concentration: The JUPITER Study

Glynn, Robert J, MacFadyen, Jean G, Ridker, Paul M · 2009 · Clinical Chemistry
Cited by 107

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background: The JUPITER (Justification for the Use of Statins in Prevention: An Intervention Trial Evaluating Rosuvastatin) trial suggests that increased high-sensitivity C-reactive protein (hsCRP) concentrations may be useful in decisions about the initiation of statin therapy for primary prevention of vascular disease. Although studies of specific populations have suggested that hsCRP is a reliable longitudinal marker, it is unclear how strongly hsCRP tracks in individuals after a single increased concentration. Methods: We evaluated tracking of hsCRP in 8901 individuals randomized to placebo in the JUPITER trial. These individuals had screening LDL cholesterol concentrations <130 mg/dL (<3.37 mmol/L) and hsCRP concentrations ≥2 mg/L, with subsequent hsCRP measurements made before randomization; at 13 weeks; 1, 2, 3, and 4 years later; and at trial termination. Longitudinal trends and associations were evaluated nonparametrically with box plots and Spearman correlations. After data transformation to achieve normality, repeated-measures regression models estimated the intraclass correlation of hsCRP, with and without controlling for known demographic, lifestyle, and medical determinants of hsCRP concentration. For comparison, we evaluated tracking of systolic and diastolic blood pressure; total, LDL, and HDL cholesterol; and fasting triglycerides. Results: The median hsCRP concentration in these untreated individuals showed modest regression to the mean over time, declining from 3.8 mg/L at randomization to 3.4 mg/L at 4 years. Tracking correlations for hsCRP over time were comparable to those for blood pressure and LDL cholesterol, but lower than those for HDL, fasting triglycerides, and total cholesterol. The intraclass correlation for repeated hsCRP measurements was 0.54 (95% CI, 0.53–0.55) without covariate adjustment and 0.50 (95% CI, 0.49–0.51) after adjustment for demographic, lifestyle, and comorbidity determinants. Conclusions: Concentrations of hsCRP show strong tracking, even after selection of individuals with initially high values. Without statin therapy, increased concentrations of hsCRP generally remain high over time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2008.120642

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 107

Metadata

Authors
Glynn, R. J., MacFadyen, J. G., & Ridker, P. M.
Venue
Clinical Chemistry
Published
2009-02-01
Volume
55
Issue
2
Pages
305-312
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2097245088
Cited by
107
References
6
FWCI
8.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.