Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 348

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Screening Panels for Detection of Monoclonal Gammopathies

Open access
Katzmann, Jerry A, Kyle, Robert A, Benson, Joanne, Larson, Dirk R, Snyder, Melissa R, Lust, John A, Rajkumar, S Vincent, Dispenzieri, Angela·2009·Clinical Chemistry

Abstract

Background: The repertoire of serologic tests for identifying a monoclonal gammopathy includes serum and urine protein electrophoresis (PEL), serum and urine immunofixation electrophoresis (IFE), and quantitative serum free light chain (FLC). Although there are several reports on the relative diagnostic contribution of these assays, none has looked at the tests singly and in combination for the various plasma cell proliferative disorders (PCPDs). Methods: Patients with a PCPD and all 5 assays performed within 30 days of diagnosis were included (n = 1877). The diagnoses were multiple myeloma (MM) (n = 467), smoldering multiple myeloma (SMM) (n = 191), monoclonal gammopathy of undetermined significance (MGUS) (n = 524), plasmacytoma (n = 29), extramedullary plasmacytoma (n = 10), Waldenström macroglobulinemia (WM) (n = 26), primary amyloidosis (AL) (n = 581), light chain deposition disease (LCDD) (n = 18), and POEMS syndrome (n = 31). Results: Of the 1877 patients, 26 were negative in all assays. Omitting urine from the panel lost an additional 23 patients (15 MGUS, 6 AL, 1 plasmacytoma, 1 LCDD), whereas the omission of FLC lost 30 patients (6 MM, 23 AL, and 1 LCDD). The omission of serum IFE as well as urine lost an additional 58 patients (44 MGUS, 7 POEMS, 5 AL, 1 SMM, and 1 plasmacytoma). Conclusions: The major impact of using a simplified screening panel of serum PEL plus FLC rather than PEL, IFE, and FLC is an 8% reduction in sensitivity for MGUS, 23% for POEMS (7 patients), 4% for plasmacytoma (1 patient), 1% for AL, and 0.5% for SMM. There is no diminution in sensitivity for detecting MM, macroglobulinemia, and LCDD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2009.126664

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 348

Metadata

Authors
Katzmann, J. A., Kyle, R. A., Benson, J., Larson, D. R., Snyder, M. R., Lust, J. A., Rajkumar, S. V., & Dispenzieri, A.
Venue
Clinical Chemistry
Published
2009-08-01
Volume
55
Issue
8
Pages
1517-1522
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2102738326
Cited by
348
References
3
FWCI
11.29
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Screening Panels for Detection of Monoclonal Gammopathies. https://app.cochat.ai/papers/10.1373/clinchem.2009.126664
The paper
Katzmann, J. A., Kyle, R. A., Benson, J., Larson, D. R., Snyder, M. R., Lust, J. A., Rajkumar, S. V., & Dispenzieri, A. (2009). Screening Panels for Detection of Monoclonal Gammopathies. Clinical Chemistry. https://doi.org/10.1373/clinchem.2009.126664

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.